{"product_id":"siemens-3va5195-4ed31-0aa0-15-amp-3-pole-molded-case-circuit-breaker-panel-mount-240-480-600y-347vac-500vdc","title":"Siemens 3VA5195-4ED31-0AA0 15 Amp 3-Pole Molded Case Circuit Breaker – Panel Mount – 240\/480\/600Y-347VAC \u0026 500VDC","description":"\u003cp data-start=\"139\" data-end=\"900\"\u003eThe Siemens 3VA5195-4ED31-0AA0 is a compact molded case circuit breaker (MCCB) engineered for commercial and industrial power distribution applications. Designed as a direct replacement for the legacy ED43B015 breaker, this 3-pole, 15A unit features a TM210 thermal-magnetic trip unit with fixed thermal and magnetic settings for dependable long-time and instantaneous (LI) protection. The breaker is designed for installation in Siemens P2 and P3 panelboards, switchboards, and electrical enclosures. With current-limiting technology, reverse-feed capability, a trip-free operating mechanism, and interrupting ratings up to 65kA at 240VAC, it provides reliable protection against overloads and short circuits in demanding electrical systems.\u003c\/p\u003e\n\u003ch3 data-section-id=\"yc43s8\" data-start=\"902\" data-end=\"924\"\u003eVoltage and Rating\u003c\/h3\u003e\n\u003cul data-start=\"925\" data-end=\"1190\"\u003e\n\u003cli data-section-id=\"15jl987\" data-start=\"925\" data-end=\"954\"\u003e\n\u003cstrong data-start=\"927\" data-end=\"946\"\u003eCurrent Rating:\u003c\/strong\u003e 15 Amps\u003c\/li\u003e\n\u003cli data-section-id=\"veiqq9\" data-start=\"955\" data-end=\"1025\"\u003e\n\u003cstrong data-start=\"957\" data-end=\"976\"\u003eVoltage Rating:\u003c\/strong\u003e 240VAC, 480Y\/277VAC, 480VAC, 600Y\/347VAC, 500VDC\u003c\/li\u003e\n\u003cli data-section-id=\"1murovg\" data-start=\"1026\" data-end=\"1046\"\u003e\n\u003cstrong data-start=\"1028\" data-end=\"1038\"\u003ePhase:\u003c\/strong\u003e 3-Phase\u003c\/li\u003e\n\u003cli data-section-id=\"1k2j0h4\" data-start=\"1047\" data-end=\"1072\"\u003e\n\u003cstrong data-start=\"1049\" data-end=\"1063\"\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\u003cli data-section-id=\"1hnj4nq\" data-start=\"1073\" data-end=\"1190\"\u003e\n\u003cstrong data-start=\"1075\" data-end=\"1090\"\u003eAIC Rating:\u003c\/strong\u003e\n\u003cul data-start=\"1093\" data-end=\"1190\"\u003e\n\u003cli data-section-id=\"hzrd8j\" data-start=\"1093\" data-end=\"1108\"\u003e65kA @ 240VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1qbwm7d\" data-start=\"1111\" data-end=\"1131\"\u003e25kA @ 480Y\/277VAC\u003c\/li\u003e\n\u003cli data-section-id=\"yr8mx9\" data-start=\"1134\" data-end=\"1149\"\u003e25kA @ 480VAC\u003c\/li\u003e\n\u003cli data-section-id=\"jpg8o3\" data-start=\"1152\" data-end=\"1172\"\u003e14kA @ 600Y\/347VAC\u003c\/li\u003e\n\u003cli data-section-id=\"oispib\" data-start=\"1175\" data-end=\"1190\"\u003e50kA @ 500VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"uvdx3z\" data-start=\"1192\" data-end=\"1214\"\u003eKey Specifications\u003c\/h3\u003e\n\u003cul data-start=\"1215\" data-end=\"1721\"\u003e\n\u003cli data-section-id=\"13z4f0o\" data-start=\"1215\" data-end=\"1269\"\u003e\n\u003cstrong data-start=\"1217\" data-end=\"1234\"\u003eBreaker Type:\u003c\/strong\u003e Molded Case Circuit Breaker (MCCB)\u003c\/li\u003e\n\u003cli data-section-id=\"l7ajc\" data-start=\"1270\" data-end=\"1288\"\u003e\n\u003cstrong data-start=\"1272\" data-end=\"1283\"\u003eSeries:\u003c\/strong\u003e 3VA5\u003c\/li\u003e\n\u003cli data-section-id=\"3v1hh9\" data-start=\"1289\" data-end=\"1326\"\u003e\n\u003cstrong data-start=\"1291\" data-end=\"1307\"\u003ePart Number:\u003c\/strong\u003e 3VA5195-4ED31-0AA0\u003c\/li\u003e\n\u003cli data-section-id=\"1b7sbdh\" data-start=\"1327\" data-end=\"1356\"\u003e\n\u003cstrong data-start=\"1329\" data-end=\"1349\"\u003eNumber of Poles:\u003c\/strong\u003e 3-Pole\u003c\/li\u003e\n\u003cli data-section-id=\"1l1n3xv\" data-start=\"1357\" data-end=\"1390\"\u003e\n\u003cstrong data-start=\"1359\" data-end=\"1378\"\u003eMounting Style:\u003c\/strong\u003e Panel Mount\u003c\/li\u003e\n\u003cli data-section-id=\"fii6mb\" data-start=\"1391\" data-end=\"1416\"\u003e\n\u003cstrong data-start=\"1393\" data-end=\"1411\"\u003eTerminal Type:\u003c\/strong\u003e Lugs\u003c\/li\u003e\n\u003cli data-section-id=\"9uld3y\" data-start=\"1417\" data-end=\"1456\"\u003e\n\u003cstrong data-start=\"1419\" data-end=\"1439\"\u003eTrip Technology:\u003c\/strong\u003e Thermal Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"1veldj5\" data-start=\"1457\" data-end=\"1479\"\u003e\n\u003cstrong data-start=\"1459\" data-end=\"1473\"\u003eTrip Unit:\u003c\/strong\u003e TM210\u003c\/li\u003e\n\u003cli data-section-id=\"10ttgyv\" data-start=\"1480\" data-end=\"1508\"\u003e\n\u003cstrong data-start=\"1482\" data-end=\"1505\"\u003eTrip Function Code:\u003c\/strong\u003e LI\u003c\/li\u003e\n\u003cli data-section-id=\"16robjh\" data-start=\"1509\" data-end=\"1568\"\u003e\n\u003cstrong data-start=\"1511\" data-end=\"1529\"\u003eTrip Function:\u003c\/strong\u003e Long-Time and Instantaneous Protection\u003c\/li\u003e\n\u003cli data-section-id=\"owid63\" data-start=\"1569\" data-end=\"1624\"\u003e\n\u003cstrong data-start=\"1571\" data-end=\"1594\"\u003eTrip Adjustability:\u003c\/strong\u003e Fixed Thermal, Fixed Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"1ykbflo\" data-start=\"1625\" data-end=\"1721\"\u003e\n\u003cstrong data-start=\"1627\" data-end=\"1644\"\u003eFor Use With:\u003c\/strong\u003e Siemens P2 Panelboards, Siemens P3 Panelboards, Switchboards, and Enclosures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"nucr17\" data-start=\"1723\" data-end=\"1751\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul data-start=\"1752\" data-end=\"2111\"\u003e\n\u003cli data-section-id=\"1tyc7py\" data-start=\"1752\" data-end=\"1855\"\u003e\n\u003cstrong data-start=\"1754\" data-end=\"1780\"\u003eConstruction Features:\u003c\/strong\u003e HACR Rated, Current Limiting, Reverse Feed, Trip-Free Mechanism, HID Rated\u003c\/li\u003e\n\u003cli data-section-id=\"h60rf3\" data-start=\"1856\" data-end=\"1895\"\u003e\n\u003cstrong data-start=\"1858\" data-end=\"1881\"\u003eTemperature Rating:\u003c\/strong\u003e -25°C to 70°C\u003c\/li\u003e\n\u003cli data-section-id=\"xsohy3\" data-start=\"1896\" data-end=\"1939\"\u003e\n\u003cstrong data-start=\"1898\" data-end=\"1923\"\u003eAccessories Included:\u003c\/strong\u003e Nut Keeper Only\u003c\/li\u003e\n\u003cli data-section-id=\"vitcby\" data-start=\"1940\" data-end=\"2111\"\u003e\n\u003cstrong data-start=\"1942\" data-end=\"1964\"\u003eAvailable Options:\u003c\/strong\u003e Auxiliary Switch, Alarm Switch, Shunt Trip, Undervoltage Release, Motor Operator, Handle Ties, Lockout Attachment, DIN Rail Adapter, Busbar System\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"nr5bwx\" data-start=\"2113\" data-end=\"2140\"\u003eStandards and Approvals\u003c\/h3\u003e\n\u003cul data-start=\"2141\" data-end=\"2243\"\u003e\n\u003cli data-section-id=\"v57bhq\" data-start=\"2141\" data-end=\"2194\"\u003e\n\u003cstrong data-start=\"2143\" data-end=\"2157\"\u003eStandards:\u003c\/strong\u003e IEC 60947-2, UL 489, CSA C22.2 No. 5\u003c\/li\u003e\n\u003cli data-section-id=\"cvm693\" data-start=\"2195\" data-end=\"2243\"\u003e\n\u003cstrong data-start=\"2197\" data-end=\"2211\"\u003eApprovals:\u003c\/strong\u003e ABS, CE, CSA, EAC, IEC, UL, VDE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1aljov1\" data-start=\"2245\" data-end=\"2261\"\u003eProduct Data\u003c\/h3\u003e\n\u003cul data-start=\"2262\" data-end=\"2346\"\u003e\n\u003cli data-section-id=\"7xjvzj\" data-start=\"2262\" data-end=\"2289\"\u003e\n\u003cstrong data-start=\"2264\" data-end=\"2281\"\u003eManufacturer:\u003c\/strong\u003e Siemens\u003c\/li\u003e\n\u003cli data-section-id=\"l7ajc\" data-start=\"2290\" data-end=\"2308\"\u003e\n\u003cstrong data-start=\"2292\" data-end=\"2303\"\u003eSeries:\u003c\/strong\u003e 3VA5\u003c\/li\u003e\n\u003cli data-section-id=\"3v1hh9\" data-start=\"2309\" data-end=\"2346\"\u003e\n\u003cstrong data-start=\"2311\" data-end=\"2327\"\u003ePart Number:\u003c\/strong\u003e 3VA5195-4ED31-0AA0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"wggvqn\" data-start=\"2348\" data-end=\"2364\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"2365\" data-end=\"2719\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\n\u003cli data-section-id=\"1e8jn5z\" data-start=\"2365\" data-end=\"2404\"\u003eCommercial Power Distribution Systems\u003c\/li\u003e\n\u003cli data-section-id=\"xl1m6\" data-start=\"2405\" data-end=\"2442\"\u003eIndustrial Electrical Installations\u003c\/li\u003e\n\u003cli data-section-id=\"1qj280n\" data-start=\"2443\" data-end=\"2474\"\u003eSiemens P2 and P3 Panelboards\u003c\/li\u003e\n\u003cli data-section-id=\"z5dh6n\" data-start=\"2475\" data-end=\"2515\"\u003eSwitchboards and Electrical Enclosures\u003c\/li\u003e\n\u003cli data-section-id=\"1lrsr2q\" data-start=\"2516\" data-end=\"2554\"\u003eFeeder and Branch Circuit Protection\u003c\/li\u003e\n\u003cli data-section-id=\"s1rvbh\" data-start=\"2555\" data-end=\"2602\"\u003eHVAC Equipment Protection (HACR Applications)\u003c\/li\u003e\n\u003cli data-section-id=\"pubehx\" data-start=\"2603\" data-end=\"2625\"\u003eHID Lighting Systems\u003c\/li\u003e\n\u003cli data-section-id=\"16epuab\" data-start=\"2626\" data-end=\"2668\"\u003eCurrent-Limiting Protection Applications\u003c\/li\u003e\n\u003cli data-section-id=\"yucevh\" data-start=\"2669\" data-end=\"2719\" data-is-last-node=\"\"\u003eReplacement of Siemens ED43B015 Circuit Breakers\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens \/ ITE","offers":[{"title":"NEW","offer_id":48490722787577,"sku":"3VA5195-4ED31-0AA0","price":404.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/3VA5195-6ED31-0AA0-3-Pole-Circuit-Breaker_Siemens_1_fcc93a3c-6ff1-4ef6-8e5a-1ea3c8af7295.webp?v=1780739446","url":"https:\/\/mycircuitbreakers.com\/products\/siemens-3va5195-4ed31-0aa0-15-amp-3-pole-molded-case-circuit-breaker-panel-mount-240-480-600y-347vac-500vdc","provider":"My Circuit Breakers","version":"1.0","type":"link"}