{"product_id":"siemens-3va5210-5ec61-0aa0-100-amp-2-pole-molded-case-circuit-breaker-panel-mount-600v-ac","title":"Siemens 3VA5210-5EC61-0AA0 100 Amp 2-Pole Molded Case Circuit Breaker – Panel Mount – 600V AC","description":"\u003cp data-start=\"119\" data-end=\"939\"\u003eThe Siemens 3VA5210-5EC61-0AA0 is a heavy-duty molded case circuit breaker (MCCB) from the SENTRON 3VA series, engineered for commercial and industrial power distribution applications. Built on the larger 3VA52 frame, this 100A, 2-pole breaker features a TM230 thermal-magnetic trip unit that provides dependable long-time and instantaneous (LI) protection. The breaker incorporates fixed overload protection (Ir) and adjustable instantaneous magnetic protection (Ii), allowing improved coordination with downstream devices. Designed with Medium (Class M) breaking capacity, it delivers reliable fault interruption up to 35kA at 480VAC and 18kA at 600VAC. Supplied without lugs, this breaker is ideal for panelboard, switchboard, and feeder protection applications requiring robust circuit protection.\u003c\/p\u003e\n\u003ch3 data-section-id=\"yc43s8\" data-start=\"941\" data-end=\"963\"\u003eVoltage and Rating\u003c\/h3\u003e\n\u003cul data-start=\"964\" data-end=\"1159\"\u003e\n\u003cli data-section-id=\"3fnw8y\" data-start=\"964\" data-end=\"994\"\u003e\n\u003cstrong data-start=\"966\" data-end=\"985\"\u003eCurrent Rating:\u003c\/strong\u003e 100 Amps\u003c\/li\u003e\n\u003cli data-section-id=\"199e4lt\" data-start=\"995\" data-end=\"1029\"\u003e\n\u003cstrong data-start=\"997\" data-end=\"1016\"\u003eVoltage Rating:\u003c\/strong\u003e 600 Volts AC\u003c\/li\u003e\n\u003cli data-section-id=\"1murovg\" data-start=\"1030\" data-end=\"1050\"\u003e\n\u003cstrong data-start=\"1032\" data-end=\"1042\"\u003ePhase:\u003c\/strong\u003e 3-Phase\u003c\/li\u003e\n\u003cli data-section-id=\"1k2j0h4\" data-start=\"1051\" data-end=\"1076\"\u003e\n\u003cstrong data-start=\"1053\" data-end=\"1067\"\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\u003cli data-section-id=\"4v2pjh\" data-start=\"1077\" data-end=\"1159\"\u003e\n\u003cstrong data-start=\"1079\" data-end=\"1094\"\u003eAIC Rating:\u003c\/strong\u003e\n\u003cul data-start=\"1097\" data-end=\"1159\"\u003e\n\u003cli data-section-id=\"16lwh6j\" data-start=\"1097\" data-end=\"1113\"\u003e100kA @ 480VAC\u003c\/li\u003e\n\u003cli data-section-id=\"4lqgni\" data-start=\"1116\" data-end=\"1141\"\u003e35kA @ 480VAC (Class M)\u003c\/li\u003e\n\u003cli data-section-id=\"1yghoyx\" data-start=\"1144\" data-end=\"1159\"\u003e18kA @ 600VAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"uvdx3z\" data-start=\"1161\" data-end=\"1183\"\u003eKey Specifications\u003c\/h3\u003e\n\u003cul data-start=\"1184\" data-end=\"1679\"\u003e\n\u003cli data-section-id=\"13z4f0o\" data-start=\"1184\" data-end=\"1238\"\u003e\n\u003cstrong data-start=\"1186\" data-end=\"1203\"\u003eBreaker Type:\u003c\/strong\u003e Molded Case Circuit Breaker (MCCB)\u003c\/li\u003e\n\u003cli data-section-id=\"8u97ot\" data-start=\"1239\" data-end=\"1267\"\u003e\n\u003cstrong data-start=\"1241\" data-end=\"1252\"\u003eSeries:\u003c\/strong\u003e SENTRON Series\u003c\/li\u003e\n\u003cli data-section-id=\"19n3f00\" data-start=\"1268\" data-end=\"1305\"\u003e\n\u003cstrong data-start=\"1270\" data-end=\"1286\"\u003ePart Number:\u003c\/strong\u003e 3VA5210-5EC61-0AA0\u003c\/li\u003e\n\u003cli data-section-id=\"420wr8\" data-start=\"1306\" data-end=\"1335\"\u003e\n\u003cstrong data-start=\"1308\" data-end=\"1323\"\u003eFrame Size:\u003c\/strong\u003e 3VA52 Frame\u003c\/li\u003e\n\u003cli data-section-id=\"1ancmt0\" data-start=\"1336\" data-end=\"1365\"\u003e\n\u003cstrong data-start=\"1338\" data-end=\"1358\"\u003eNumber of Poles:\u003c\/strong\u003e 2-Pole\u003c\/li\u003e\n\u003cli data-section-id=\"16mor7d\" data-start=\"1366\" data-end=\"1396\"\u003e\n\u003cstrong data-start=\"1368\" data-end=\"1386\"\u003eConfiguration:\u003c\/strong\u003e 2(3)-Pole\u003c\/li\u003e\n\u003cli data-section-id=\"1l1n3xv\" data-start=\"1397\" data-end=\"1430\"\u003e\n\u003cstrong data-start=\"1399\" data-end=\"1418\"\u003eMounting Style:\u003c\/strong\u003e Panel Mount\u003c\/li\u003e\n\u003cli data-section-id=\"9uld3y\" data-start=\"1431\" data-end=\"1470\"\u003e\n\u003cstrong data-start=\"1433\" data-end=\"1453\"\u003eTrip Technology:\u003c\/strong\u003e Thermal Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"1veldkz\" data-start=\"1471\" data-end=\"1493\"\u003e\n\u003cstrong data-start=\"1473\" data-end=\"1487\"\u003eTrip Unit:\u003c\/strong\u003e TM230\u003c\/li\u003e\n\u003cli data-section-id=\"11tkps9\" data-start=\"1494\" data-end=\"1558\"\u003e\n\u003cstrong data-start=\"1496\" data-end=\"1514\"\u003eTrip Function:\u003c\/strong\u003e Long-Time and Instantaneous Protection (LI)\u003c\/li\u003e\n\u003cli data-section-id=\"1tu5les\" data-start=\"1559\" data-end=\"1608\"\u003e\n\u003cstrong data-start=\"1561\" data-end=\"1584\"\u003eTrip Adjustability:\u003c\/strong\u003e Fixed Ir, Adjustable Ii\u003c\/li\u003e\n\u003cli data-section-id=\"11os7b7\" data-start=\"1609\" data-end=\"1643\"\u003e\n\u003cstrong data-start=\"1611\" data-end=\"1631\"\u003eProtection Type:\u003c\/strong\u003e Solid State\u003c\/li\u003e\n\u003cli data-section-id=\"g4x7rx\" data-start=\"1644\" data-end=\"1679\"\u003e\n\u003cstrong data-start=\"1646\" data-end=\"1666\"\u003eConnection Type:\u003c\/strong\u003e Without Lugs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"nucr17\" data-start=\"1681\" data-end=\"1709\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul data-start=\"1710\" data-end=\"1973\"\u003e\n\u003cli data-section-id=\"y6gklk\" data-start=\"1710\" data-end=\"1757\"\u003e\n\u003cstrong data-start=\"1712\" data-end=\"1740\"\u003eBreaking Capacity Class:\u003c\/strong\u003e Medium (Class M)\u003c\/li\u003e\n\u003cli data-section-id=\"1c10ev9\" data-start=\"1758\" data-end=\"1800\"\u003e\n\u003cstrong data-start=\"1760\" data-end=\"1784\"\u003eOverload Protection:\u003c\/strong\u003e 100A Fixed (Ir)\u003c\/li\u003e\n\u003cli data-section-id=\"1mqi5ni\" data-start=\"1801\" data-end=\"1862\"\u003e\n\u003cstrong data-start=\"1803\" data-end=\"1832\"\u003eInstantaneous Protection:\u003c\/strong\u003e Adjustable Magnetic Trip (Ii)\u003c\/li\u003e\n\u003cli data-section-id=\"yf2079\" data-start=\"1863\" data-end=\"1909\"\u003e\n\u003cstrong data-start=\"1865\" data-end=\"1882\"\u003eConstruction:\u003c\/strong\u003e Compact Molded Case Design\u003c\/li\u003e\n\u003cli data-section-id=\"1k7miyl\" data-start=\"1910\" data-end=\"1973\"\u003e\n\u003cstrong data-start=\"1912\" data-end=\"1928\"\u003eApplication:\u003c\/strong\u003e Commercial and Industrial Power Distribution\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"nr5bwx\" data-start=\"1975\" data-end=\"2002\"\u003eStandards and Approvals\u003c\/h3\u003e\n\u003cul data-start=\"2003\" data-end=\"2036\"\u003e\n\u003cli data-section-id=\"19vv1m8\" data-start=\"2003\" data-end=\"2036\"\u003e\n\u003cstrong data-start=\"2005\" data-end=\"2023\"\u003eCertification:\u003c\/strong\u003e CSA Approved\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1aljov1\" data-start=\"2038\" data-end=\"2054\"\u003eProduct Data\u003c\/h3\u003e\n\u003cul data-start=\"2055\" data-end=\"2160\"\u003e\n\u003cli data-section-id=\"7xjvzj\" data-start=\"2055\" data-end=\"2082\"\u003e\n\u003cstrong data-start=\"2057\" data-end=\"2074\"\u003eManufacturer:\u003c\/strong\u003e Siemens\u003c\/li\u003e\n\u003cli data-section-id=\"rrg5iu\" data-start=\"2083\" data-end=\"2104\"\u003e\n\u003cstrong data-start=\"2085\" data-end=\"2096\"\u003eSeries:\u003c\/strong\u003e SENTRON\u003c\/li\u003e\n\u003cli data-section-id=\"19n3f00\" data-start=\"2105\" data-end=\"2142\"\u003e\n\u003cstrong data-start=\"2107\" data-end=\"2123\"\u003ePart Number:\u003c\/strong\u003e 3VA5210-5EC61-0AA0\u003c\/li\u003e\n\u003cli data-section-id=\"7o3gqo\" data-start=\"2143\" data-end=\"2160\"\u003e\n\u003cstrong data-start=\"2145\" data-end=\"2156\"\u003eFamily:\u003c\/strong\u003e 3VA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"ddop7y\" data-start=\"2162\" data-end=\"2187\"\u003eDimensions and Weight\u003c\/h3\u003e\n\u003cul data-start=\"2188\" data-end=\"2272\"\u003e\n\u003cli data-section-id=\"1qsvjo8\" data-start=\"2188\" data-end=\"2207\"\u003e\n\u003cstrong data-start=\"2190\" data-end=\"2200\"\u003eWidth:\u003c\/strong\u003e 4.1 in\u003c\/li\u003e\n\u003cli data-section-id=\"b2z4e8\" data-start=\"2208\" data-end=\"2228\"\u003e\n\u003cstrong data-start=\"2210\" data-end=\"2221\"\u003eHeight:\u003c\/strong\u003e 7.3 in\u003c\/li\u003e\n\u003cli data-section-id=\"17hclm8\" data-start=\"2229\" data-end=\"2248\"\u003e\n\u003cstrong data-start=\"2231\" data-end=\"2241\"\u003eDepth:\u003c\/strong\u003e 4.2 in\u003c\/li\u003e\n\u003cli data-section-id=\"9t33ad\" data-start=\"2249\" data-end=\"2272\"\u003e\n\u003cstrong data-start=\"2251\" data-end=\"2262\"\u003eWeight:\u003c\/strong\u003e 4.189 lbs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"wggvqn\" data-start=\"2274\" data-end=\"2290\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"2291\" data-end=\"2629\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\n\u003cli data-section-id=\"1e8jn5z\" data-start=\"2291\" data-end=\"2330\"\u003eCommercial Power Distribution Systems\u003c\/li\u003e\n\u003cli data-section-id=\"xl1m6\" data-start=\"2331\" data-end=\"2368\"\u003eIndustrial Electrical Installations\u003c\/li\u003e\n\u003cli data-section-id=\"mioo3r\" data-start=\"2369\" data-end=\"2399\"\u003ePanelboards and Switchboards\u003c\/li\u003e\n\u003cli data-section-id=\"ahqzl9\" data-start=\"2400\" data-end=\"2427\"\u003eFeeder Circuit Protection\u003c\/li\u003e\n\u003cli data-section-id=\"zwhbd8\" data-start=\"2428\" data-end=\"2455\"\u003eBranch Circuit Protection\u003c\/li\u003e\n\u003cli data-section-id=\"1pcj2h0\" data-start=\"2456\" data-end=\"2492\"\u003eEquipment and Machinery Protection\u003c\/li\u003e\n\u003cli data-section-id=\"43q6rx\" data-start=\"2493\" data-end=\"2521\"\u003eMotor Control Applications\u003c\/li\u003e\n\u003cli data-section-id=\"uk75xg\" data-start=\"2522\" data-end=\"2557\"\u003eLow-Voltage Distribution Networks\u003c\/li\u003e\n\u003cli data-section-id=\"1alk6tf\" data-start=\"2558\" data-end=\"2591\"\u003eHigh Fault Current Environments\u003c\/li\u003e\n\u003cli data-section-id=\"1dklbos\" data-start=\"2592\" data-end=\"2629\" data-is-last-node=\"\"\u003eCurrent-Limiting Protection Systems\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens \/ ITE","offers":[{"title":"NEW","offer_id":48490724032761,"sku":"3VA5210-5EC61-0AA0","price":957.16,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/3VA5210-5EC61-0AA0-All-New-1_8d185bfe-9b58-4433-98f5-e85dd2727b72.webp?v=1780739962","url":"https:\/\/mycircuitbreakers.com\/products\/siemens-3va5210-5ec61-0aa0-100-amp-2-pole-molded-case-circuit-breaker-panel-mount-600v-ac","provider":"My Circuit Breakers","version":"1.0","type":"link"}