{"product_id":"siemens-3va5217-6ec31-0aa0-175-amp-3-pole-molded-case-circuit-breaker-panel-mount-240-480-600vac-750vdc","title":"Siemens 3VA5217-6EC31-0AA0 175 Amp 3-Pole Molded Case Circuit Breaker – Panel Mount – 240\/480\/600VAC \u0026 750VDC","description":"\u003cdiv class=\"qMYqUG_convSearchResultHighlightRoot\"\u003e\n\u003cdiv class=\"\" data-turn-id-container=\"request-6a21ac48-87a0-83ec-890f-5a08b3a83112-16\" data-is-intersecting=\"true\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none has-data-writing-block:pointer-events-none [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-6a21ac48-87a0-83ec-890f-5a08b3a83112-16\" data-turn-id-container=\"request-6a21ac48-87a0-83ec-890f-5a08b3a83112-16\" data-testid=\"conversation-turn-86\" data-scroll-anchor=\"false\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv data-conversation-screenshot-content=\"\" class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"47998cf3-5ce7-41f8-98fa-dfb833ef3e1d\" dir=\"auto\" data-message-model-slug=\"gpt-5-3-mini\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" data-turn-start-message=\"true\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert wrap-break-word w-full dark markdown-new-styling\"\u003e\n\u003cp data-start=\"135\" data-end=\"870\"\u003eThe Siemens 3VA5217-6EC31-0AA0 is a high-performance molded case circuit breaker (MCCB) from the SENTRON 3VA5 series, designed for high-fault commercial and industrial power distribution systems. Built on the robust 3VA52 frame, this 175A, 3-pole breaker delivers dependable long-time and instantaneous (LI) protection using a fixed thermal and adjustable magnetic trip unit. With High (Class H) breaking capacity, it provides strong fault interruption performance rated up to 65kA at 480VAC and extended protection across AC and DC systems up to 750VDC. The breaker is designed for Siemens 3VA panelboards, switchboards, and P2 panelboards (with mounting kit), and includes a nut keeper kit for secure installation.\u003c\/p\u003e\n\u003ch3 data-section-id=\"yc43s8\" data-start=\"872\" data-end=\"894\"\u003eVoltage and Rating\u003c\/h3\u003e\n\u003cul data-start=\"895\" data-end=\"1210\"\u003e\n\u003cli data-section-id=\"5azvds\" data-start=\"895\" data-end=\"927\"\u003e\n\u003cstrong data-start=\"897\" data-end=\"916\"\u003eCurrent Rating:\u003c\/strong\u003e 175 Amps\u003c\/li\u003e\n\u003cli data-section-id=\"smjmhk\" data-start=\"928\" data-end=\"1008\"\u003e\n\u003cstrong data-start=\"930\" data-end=\"949\"\u003eVoltage Rating:\u003c\/strong\u003e 240VAC, 480Y\/277VAC, 480VAC, 600Y\/347VAC, 600VAC, 750VDC\u003c\/li\u003e\n\u003cli data-section-id=\"mw1woc\" data-start=\"1009\" data-end=\"1031\"\u003e\n\u003cstrong data-start=\"1011\" data-end=\"1021\"\u003ePhase:\u003c\/strong\u003e 3-Phase\u003c\/li\u003e\n\u003cli data-section-id=\"18xe814\" data-start=\"1032\" data-end=\"1059\"\u003e\n\u003cstrong data-start=\"1034\" data-end=\"1048\"\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\u003cli data-section-id=\"ccjlcx\" data-start=\"1060\" data-end=\"1210\"\u003e\n\u003cstrong data-start=\"1062\" data-end=\"1077\"\u003eAIC Rating:\u003c\/strong\u003e\n\u003cul data-start=\"1082\" data-end=\"1210\"\u003e\n\u003cli data-section-id=\"xdywmp\" data-start=\"1082\" data-end=\"1100\"\u003e100kA @ 240VAC\u003c\/li\u003e\n\u003cli data-section-id=\"w5hfn1\" data-start=\"1103\" data-end=\"1125\"\u003e65kA @ 480Y\/277VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1va4555\" data-start=\"1128\" data-end=\"1145\"\u003e65kA @ 480VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1u29d1d\" data-start=\"1148\" data-end=\"1170\"\u003e25kA @ 600Y\/347VAC\u003c\/li\u003e\n\u003cli data-section-id=\"j7s8uf\" data-start=\"1173\" data-end=\"1190\"\u003e25kA @ 600VAC\u003c\/li\u003e\n\u003cli data-section-id=\"p5olvw\" data-start=\"1193\" data-end=\"1210\"\u003e85kA @ 750VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"uvdx3z\" data-start=\"1212\" data-end=\"1234\"\u003eKey Specifications\u003c\/h3\u003e\n\u003cul data-start=\"1235\" data-end=\"1876\"\u003e\n\u003cli data-section-id=\"1qjor2g\" data-start=\"1235\" data-end=\"1291\"\u003e\n\u003cstrong data-start=\"1237\" data-end=\"1254\"\u003eBreaker Type:\u003c\/strong\u003e Molded Case Circuit Breaker (MCCB)\u003c\/li\u003e\n\u003cli data-section-id=\"zndl3\" data-start=\"1292\" data-end=\"1320\"\u003e\n\u003cstrong data-start=\"1294\" data-end=\"1305\"\u003eSeries:\u003c\/strong\u003e SENTRON 3VA5\u003c\/li\u003e\n\u003cli data-section-id=\"15an0cg\" data-start=\"1321\" data-end=\"1340\"\u003e\n\u003cstrong data-start=\"1323\" data-end=\"1334\"\u003eFamily:\u003c\/strong\u003e 3VA\u003c\/li\u003e\n\u003cli data-section-id=\"13a0o8h\" data-start=\"1341\" data-end=\"1380\"\u003e\n\u003cstrong data-start=\"1343\" data-end=\"1359\"\u003ePart Number:\u003c\/strong\u003e 3VA5217-6EC31-0AA0\u003c\/li\u003e\n\u003cli data-section-id=\"dcjhsk\" data-start=\"1381\" data-end=\"1412\"\u003e\n\u003cstrong data-start=\"1383\" data-end=\"1398\"\u003eFrame Size:\u003c\/strong\u003e 3VA52 Frame\u003c\/li\u003e\n\u003cli data-section-id=\"1r74djp\" data-start=\"1413\" data-end=\"1444\"\u003e\n\u003cstrong data-start=\"1415\" data-end=\"1435\"\u003eNumber of Poles:\u003c\/strong\u003e 3-Pole\u003c\/li\u003e\n\u003cli data-section-id=\"15nm9pv\" data-start=\"1445\" data-end=\"1480\"\u003e\n\u003cstrong data-start=\"1447\" data-end=\"1466\"\u003eMounting Style:\u003c\/strong\u003e Panel Mount\u003c\/li\u003e\n\u003cli data-section-id=\"1ogd7r7\" data-start=\"1481\" data-end=\"1508\"\u003e\n\u003cstrong data-start=\"1483\" data-end=\"1501\"\u003eTerminal Type:\u003c\/strong\u003e Lugs\u003c\/li\u003e\n\u003cli data-section-id=\"s9au6\" data-start=\"1509\" data-end=\"1550\"\u003e\n\u003cstrong data-start=\"1511\" data-end=\"1531\"\u003eTrip Technology:\u003c\/strong\u003e Thermal Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"18kzdbb\" data-start=\"1551\" data-end=\"1581\"\u003e\n\u003cstrong data-start=\"1553\" data-end=\"1576\"\u003eTrip Function Code:\u003c\/strong\u003e LI\u003c\/li\u003e\n\u003cli data-section-id=\"1dxx71p\" data-start=\"1582\" data-end=\"1643\"\u003e\n\u003cstrong data-start=\"1584\" data-end=\"1602\"\u003eTrip Function:\u003c\/strong\u003e Long-Time and Instantaneous Protection\u003c\/li\u003e\n\u003cli data-section-id=\"hlv56\" data-start=\"1644\" data-end=\"1706\"\u003e\n\u003cstrong data-start=\"1646\" data-end=\"1669\"\u003eTrip Adjustability:\u003c\/strong\u003e Fixed Thermal, Adjustable Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"12rvexo\" data-start=\"1707\" data-end=\"1748\"\u003e\n\u003cstrong data-start=\"1709\" data-end=\"1729\"\u003eProtection Type:\u003c\/strong\u003e Thermal Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"13nq1gd\" data-start=\"1749\" data-end=\"1876\"\u003e\n\u003cstrong data-start=\"1751\" data-end=\"1780\"\u003eConnection Configuration:\u003c\/strong\u003e Without Lugs (factory-supplied configuration noted as included accessories per specification)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"nucr17\" data-start=\"1878\" data-end=\"1906\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul data-start=\"1907\" data-end=\"2230\"\u003e\n\u003cli data-section-id=\"1tt942m\" data-start=\"1907\" data-end=\"1954\"\u003e\n\u003cstrong data-start=\"1909\" data-end=\"1937\"\u003eBreaking Capacity Class:\u003c\/strong\u003e High (Class H)\u003c\/li\u003e\n\u003cli data-section-id=\"198kwv1\" data-start=\"1955\" data-end=\"2020\"\u003e\n\u003cstrong data-start=\"1957\" data-end=\"1973\"\u003eApplication:\u003c\/strong\u003e Industrial and Commercial Power Distribution\u003c\/li\u003e\n\u003cli data-section-id=\"18n1p8l\" data-start=\"2021\" data-end=\"2129\"\u003e\n\u003cstrong data-start=\"2023\" data-end=\"2041\"\u003eCompatibility:\u003c\/strong\u003e Siemens 3VA Panelboards, Siemens P2 Panelboards (requires mounting kit), Switchboards\u003c\/li\u003e\n\u003cli data-section-id=\"1dwdgrd\" data-start=\"2130\" data-end=\"2174\"\u003e\n\u003cstrong data-start=\"2132\" data-end=\"2157\"\u003eAccessories Included:\u003c\/strong\u003e Nut Keeper Kit\u003c\/li\u003e\n\u003cli data-section-id=\"nd8nlk\" data-start=\"2175\" data-end=\"2230\"\u003e\n\u003cstrong data-start=\"2177\" data-end=\"2203\"\u003eConstruction Features:\u003c\/strong\u003e HACR Rated, Reverse Feed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"nr5bwx\" data-start=\"2232\" data-end=\"2259\"\u003eStandards and Approvals\u003c\/h3\u003e\n\u003cul data-start=\"2260\" data-end=\"2345\"\u003e\n\u003cli data-section-id=\"k59kzm\" data-start=\"2260\" data-end=\"2304\"\u003e\n\u003cstrong data-start=\"2262\" data-end=\"2276\"\u003eStandards:\u003c\/strong\u003e IEC 60947-2, UL 489, HACR\u003c\/li\u003e\n\u003cli data-section-id=\"fit4qg\" data-start=\"2305\" data-end=\"2345\"\u003e\n\u003cstrong data-start=\"2307\" data-end=\"2321\"\u003eApprovals:\u003c\/strong\u003e CE, CSA, EAC, UL, VDE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1aljov1\" data-start=\"2347\" data-end=\"2363\"\u003eProduct Data\u003c\/h3\u003e\n\u003cul data-start=\"2364\" data-end=\"2462\"\u003e\n\u003cli data-section-id=\"177zzjj\" data-start=\"2364\" data-end=\"2393\"\u003e\n\u003cstrong data-start=\"2366\" data-end=\"2383\"\u003eManufacturer:\u003c\/strong\u003e Siemens\u003c\/li\u003e\n\u003cli data-section-id=\"zndl3\" data-start=\"2394\" data-end=\"2422\"\u003e\n\u003cstrong data-start=\"2396\" data-end=\"2407\"\u003eSeries:\u003c\/strong\u003e SENTRON 3VA5\u003c\/li\u003e\n\u003cli data-section-id=\"13a0o8h\" data-start=\"2423\" data-end=\"2462\"\u003e\n\u003cstrong data-start=\"2425\" data-end=\"2441\"\u003ePart Number:\u003c\/strong\u003e 3VA5217-6EC31-0AA0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"wggvqn\" data-start=\"2464\" data-end=\"2480\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"2481\" data-end=\"2860\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\n\u003cli data-section-id=\"e0rm6s\" data-start=\"2481\" data-end=\"2522\"\u003eHigh Fault Current Industrial Systems\u003c\/li\u003e\n\u003cli data-section-id=\"ia8n1c\" data-start=\"2523\" data-end=\"2561\"\u003eCommercial Electrical Distribution\u003c\/li\u003e\n\u003cli data-section-id=\"hke747\" data-start=\"2562\" data-end=\"2594\"\u003ePanelboards and Switchboards\u003c\/li\u003e\n\u003cli data-section-id=\"1thb30\" data-start=\"2595\" data-end=\"2620\"\u003eMotor Control Centers\u003c\/li\u003e\n\u003cli data-section-id=\"1fk2hzm\" data-start=\"2621\" data-end=\"2661\"\u003eFeeder and Branch Circuit Protection\u003c\/li\u003e\n\u003cli data-section-id=\"p97r7x\" data-start=\"2662\" data-end=\"2703\"\u003eCritical Infrastructure Power Systems\u003c\/li\u003e\n\u003cli data-section-id=\"1v8wvkn\" data-start=\"2704\" data-end=\"2748\"\u003eHigh-Interrupting Capacity Installations\u003c\/li\u003e\n\u003cli data-section-id=\"ip4pqp\" data-start=\"2749\" data-end=\"2784\"\u003eAC and DC Distribution Networks\u003c\/li\u003e\n\u003cli data-section-id=\"1v1mmfr\" data-start=\"2785\" data-end=\"2817\"\u003eEquipment Protection Systems\u003c\/li\u003e\n\u003cli data-section-id=\"16epuab\" data-start=\"2818\" data-end=\"2860\" data-is-last-node=\"\"\u003eCurrent-Limiting Protection Applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"z-0 flex min-h-[46px] justify-start\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"mt-3 w-full empty:hidden\"\u003e\n\u003cdiv class=\"text-center\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Siemens \/ ITE","offers":[{"title":"NEW","offer_id":48490881745145,"sku":"3VA5217-6EC31-0AA0","price":1611.63,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/3VA5195-6ED31-0AA0-3-Pole-Circuit-Breaker_Siemens_1_a628ee05-c518-4ac4-bdc1-fede6a723bee.webp?v=1780746154","url":"https:\/\/mycircuitbreakers.com\/products\/siemens-3va5217-6ec31-0aa0-175-amp-3-pole-molded-case-circuit-breaker-panel-mount-240-480-600vac-750vdc","provider":"My Circuit Breakers","version":"1.0","type":"link"}