{"product_id":"siemens-3va5225-5ed31-0aa0-250-amp-3-pole-molded-case-circuit-breaker-panel-mount-240-480-600vac-750vdc-rated","title":"Siemens 3VA5225-5ED31-0AA0 250 Amp 3-Pole Molded Case Circuit Breaker – Panel Mount – 240\/480\/600VAC \u0026 750VDC Rated","description":"\u003cp data-start=\"144\" data-end=\"914\"\u003eThe \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eSiemens\u003c\/span\u003e\u003c\/span\u003e 3VA5225-5ED31-0AA0 is a heavy-duty molded case circuit breaker (MCCB) from the SENTRON 3VA5 series, designed for reliable protection in commercial, industrial, and marine power distribution systems. Built on a robust 3VA52 frame, this 250A, 3-pole breaker is equipped with a TM210 thermal-magnetic trip unit featuring fixed thermal and magnetic protection for dependable fault interruption. With a Class M breaking capacity and strong short-circuit performance, it ensures safe operation in high-energy electrical environments. The breaker is compatible with Siemens P1, P2, and P3 panelboards, switchboards, and motor control centers, and serves as a cross-reference replacement for legacy FXD63B250 units.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1yl5694\" data-start=\"921\" data-end=\"939\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-start=\"941\" data-end=\"1266\"\u003e\n\u003cli data-section-id=\"ssgl78\" data-start=\"941\" data-end=\"993\"\u003e\n\u003cstrong data-start=\"943\" data-end=\"953\"\u003eBrand:\u003c\/strong\u003e \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eSiemens\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"23l9ug\" data-start=\"994\" data-end=\"1014\"\u003e\n\u003cstrong data-start=\"996\" data-end=\"1007\"\u003eSeries:\u003c\/strong\u003e 3VA5\u003c\/li\u003e\n\u003cli data-section-id=\"vbk2r8\" data-start=\"1015\" data-end=\"1054\"\u003e\n\u003cstrong data-start=\"1017\" data-end=\"1033\"\u003ePart Number:\u003c\/strong\u003e 3VA5225-5ED31-0AA0\u003c\/li\u003e\n\u003cli data-section-id=\"zfwgx8\" data-start=\"1055\" data-end=\"1077\"\u003e\n\u003cstrong data-start=\"1057\" data-end=\"1070\"\u003eAmperage:\u003c\/strong\u003e 250A\u003c\/li\u003e\n\u003cli data-section-id=\"ocwfzk\" data-start=\"1078\" data-end=\"1132\"\u003e\n\u003cstrong data-start=\"1080\" data-end=\"1099\"\u003eVoltage Rating:\u003c\/strong\u003e 240VAC, 480VAC, 600VAC, 750VDC\u003c\/li\u003e\n\u003cli data-section-id=\"7ukl44\" data-start=\"1133\" data-end=\"1149\"\u003e\n\u003cstrong data-start=\"1135\" data-end=\"1145\"\u003ePoles:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003cli data-section-id=\"1p6cxzi\" data-start=\"1150\" data-end=\"1166\"\u003e\n\u003cstrong data-start=\"1152\" data-end=\"1162\"\u003ePhase:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003cli data-section-id=\"2xa8sy\" data-start=\"1167\" data-end=\"1266\"\u003e\n\u003cstrong data-start=\"1169\" data-end=\"1184\"\u003eAIC Rating:\u003c\/strong\u003e\n\u003cul data-start=\"1189\" data-end=\"1266\"\u003e\n\u003cli data-section-id=\"v44hjh\" data-start=\"1189\" data-end=\"1206\"\u003e85kA @ 240VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1kvlimk\" data-start=\"1209\" data-end=\"1226\"\u003e35kA @ 480VAC\u003c\/li\u003e\n\u003cli data-section-id=\"fhl3qh\" data-start=\"1229\" data-end=\"1246\"\u003e18kA @ 600VAC\u003c\/li\u003e\n\u003cli data-section-id=\"4nol5w\" data-start=\"1249\" data-end=\"1266\"\u003e50kA @ 750VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"8z0n\" data-start=\"1273\" data-end=\"1308\"\u003eMechanical \u0026amp; Electrical Details\u003c\/h3\u003e\n\u003cul data-start=\"1310\" data-end=\"1859\"\u003e\n\u003cli data-section-id=\"15nm9pv\" data-start=\"1310\" data-end=\"1345\"\u003e\n\u003cstrong data-start=\"1312\" data-end=\"1331\"\u003eMounting Style:\u003c\/strong\u003e Panel Mount\u003c\/li\u003e\n\u003cli data-section-id=\"1ogd7r7\" data-start=\"1346\" data-end=\"1373\"\u003e\n\u003cstrong data-start=\"1348\" data-end=\"1366\"\u003eTerminal Type:\u003c\/strong\u003e Lugs\u003c\/li\u003e\n\u003cli data-section-id=\"a1g1z7\" data-start=\"1374\" data-end=\"1466\"\u003e\n\u003cstrong data-start=\"1376\" data-end=\"1393\"\u003eFor Use With:\u003c\/strong\u003e Siemens P1, P2, P3 Panelboards, SB Switchboards, Motor Control Centers\u003c\/li\u003e\n\u003cli data-section-id=\"s9au6\" data-start=\"1467\" data-end=\"1508\"\u003e\n\u003cstrong data-start=\"1469\" data-end=\"1489\"\u003eTrip Technology:\u003c\/strong\u003e Thermal Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"18kzdbb\" data-start=\"1509\" data-end=\"1539\"\u003e\n\u003cstrong data-start=\"1511\" data-end=\"1534\"\u003eTrip Function Code:\u003c\/strong\u003e LI\u003c\/li\u003e\n\u003cli data-section-id=\"1dpsjd5\" data-start=\"1540\" data-end=\"1587\"\u003e\n\u003cstrong data-start=\"1542\" data-end=\"1560\"\u003eTrip Function:\u003c\/strong\u003e Long-Time, Instantaneous\u003c\/li\u003e\n\u003cli data-section-id=\"1knnh9n\" data-start=\"1588\" data-end=\"1645\"\u003e\n\u003cstrong data-start=\"1590\" data-end=\"1613\"\u003eTrip Adjustability:\u003c\/strong\u003e Fixed Thermal, Fixed Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"1bxgrec\" data-start=\"1646\" data-end=\"1805\"\u003e\n\u003cstrong data-start=\"1648\" data-end=\"1674\"\u003eAccessories Available:\u003c\/strong\u003e Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Motor Operator, Rotary Handle, Padlock Attachment, Handle Lock\u003c\/li\u003e\n\u003cli data-section-id=\"1h15p77\" data-start=\"1806\" data-end=\"1859\"\u003e\n\u003cstrong data-start=\"1808\" data-end=\"1833\"\u003eAccessories Included:\u003c\/strong\u003e None (No Lugs Included)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"131luvw\" data-start=\"1866\" data-end=\"1891\"\u003eStandards \u0026amp; Approvals\u003c\/h3\u003e\n\u003cul data-start=\"1893\" data-end=\"1965\"\u003e\n\u003cli data-section-id=\"1pw3smc\" data-start=\"1893\" data-end=\"1908\"\u003eIEC 60947-2\u003c\/li\u003e\n\u003cli data-section-id=\"6d8czo\" data-start=\"1909\" data-end=\"1919\"\u003eUL 489\u003c\/li\u003e\n\u003cli data-section-id=\"12xbscc\" data-start=\"1920\" data-end=\"1939\"\u003eCSA C22.2 No. 5\u003c\/li\u003e\n\u003cli data-section-id=\"1iaapva\" data-start=\"1940\" data-end=\"1965\"\u003eCE, CSA, EAC, UL, VDE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"lg37j6\" data-start=\"1972\" data-end=\"2013\"\u003eEnvironmental \u0026amp; Construction Features\u003c\/h3\u003e\n\u003cul data-start=\"2015\" data-end=\"2158\"\u003e\n\u003cli data-section-id=\"1at0y7p\" data-start=\"2015\" data-end=\"2055\"\u003eOperating Temperature: -25°C to 70°C\u003c\/li\u003e\n\u003cli data-section-id=\"k2kph2\" data-start=\"2056\" data-end=\"2070\"\u003eHACR Rated\u003c\/li\u003e\n\u003cli data-section-id=\"laxi8k\" data-start=\"2071\" data-end=\"2091\"\u003eCurrent Limiting\u003c\/li\u003e\n\u003cli data-section-id=\"vtv0re\" data-start=\"2092\" data-end=\"2119\"\u003eReverse Feed Capability\u003c\/li\u003e\n\u003cli data-section-id=\"1uddj8m\" data-start=\"2120\" data-end=\"2158\"\u003eNon-Interchangeable Trip Mechanism\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"wggvqn\" data-start=\"2165\" data-end=\"2181\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"2183\" data-end=\"2524\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\n\u003cli data-section-id=\"yajdh8\" data-start=\"2183\" data-end=\"2224\"\u003eIndustrial Power Distribution Systems\u003c\/li\u003e\n\u003cli data-section-id=\"t48jth\" data-start=\"2225\" data-end=\"2264\"\u003eCommercial Electrical Installations\u003c\/li\u003e\n\u003cli data-section-id=\"1ixr3gs\" data-start=\"2265\" data-end=\"2294\"\u003eMarine Electrical Systems\u003c\/li\u003e\n\u003cli data-section-id=\"hke747\" data-start=\"2295\" data-end=\"2327\"\u003ePanelboards and Switchboards\u003c\/li\u003e\n\u003cli data-section-id=\"1p5etfn\" data-start=\"2328\" data-end=\"2360\"\u003eMotor Control Centers (MCCs)\u003c\/li\u003e\n\u003cli data-section-id=\"1fk2hzm\" data-start=\"2361\" data-end=\"2401\"\u003eFeeder and Branch Circuit Protection\u003c\/li\u003e\n\u003cli data-section-id=\"u5b0n7\" data-start=\"2402\" data-end=\"2437\"\u003eHigh Fault Current Environments\u003c\/li\u003e\n\u003cli data-section-id=\"1piqdzb\" data-start=\"2438\" data-end=\"2485\"\u003eCritical Infrastructure Electrical Networks\u003c\/li\u003e\n\u003cli data-section-id=\"kckn3k\" data-start=\"2486\" data-end=\"2524\" data-is-last-node=\"\"\u003eHeavy-Duty Load Distribution Systems\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens \/ ITE","offers":[{"title":"NEW","offer_id":48490944299257,"sku":"3VA5225-5ED31-0AA0","price":1541.78,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/3VA5210-5EC61-0AA0-All-New-1_66d2063f-1251-4953-9f75-09ac879760fe.webp?v=1780748730","url":"https:\/\/mycircuitbreakers.com\/products\/siemens-3va5225-5ed31-0aa0-250-amp-3-pole-molded-case-circuit-breaker-panel-mount-240-480-600vac-750vdc-rated","provider":"My Circuit Breakers","version":"1.0","type":"link"}