{"product_id":"siemens-3va6225-8hn31-0aa0-250-amp-3-pole-molded-case-circuit-breaker-panel-mount-high-interrupting-capacity-150ka-480vac","title":"Siemens 3VA6225-8HN31-0AA0 250 Amp 3-Pole Molded Case Circuit Breaker – Panel Mount – High Interrupting Capacity (150kA @ 480VAC)","description":"\u003cp data-start=\"153\" data-end=\"793\"\u003eThe Siemens 3VA6225-8HN31-0AA0 is a high-performance molded case circuit breaker (MCCB) from the SENTRON 3VA6 series, engineered for industrial and commercial power distribution systems requiring very high fault current protection. Built on the 3VA62 frame, this 250A, 3-pole breaker delivers reliable long-time and instantaneous (LI) protection using a fixed thermal and fixed magnetic trip configuration. It is designed for integration into Siemens 3VA panelboards, switchboards, and motor control centers, providing a modern solution for high-energy electrical systems where maximum short-circuit protection is critical.\u003c\/p\u003e\n\u003ch3 data-section-id=\"yc43s8\" data-start=\"795\" data-end=\"817\"\u003eVoltage and Rating\u003c\/h3\u003e\n\u003cul data-start=\"819\" data-end=\"1087\"\u003e\n\u003cli data-section-id=\"dn5rib\" data-start=\"819\" data-end=\"845\"\u003eCurrent Rating: 250 Amps\u003c\/li\u003e\n\u003cli data-section-id=\"1yidgwo\" data-start=\"846\" data-end=\"886\"\u003eVoltage Rating: 240VAC, 480VAC, 600VAC\u003c\/li\u003e\n\u003cli data-section-id=\"ratnkb\" data-start=\"887\" data-end=\"903\"\u003ePhase: 3-Phase\u003c\/li\u003e\n\u003cli data-section-id=\"jjdfan\" data-start=\"904\" data-end=\"925\"\u003eFrequency: 50\/60 Hz\u003c\/li\u003e\n\u003cli data-section-id=\"iyh55v\" data-start=\"926\" data-end=\"1087\"\u003eAIC Rating:\n\u003cul data-start=\"942\" data-end=\"1087\"\u003e\n\u003cli data-section-id=\"wtmqtj\" data-start=\"942\" data-end=\"1000\"\u003e150kA @ 480VAC (very high interrupting capacity version)\u003c\/li\u003e\n\u003cli data-section-id=\"hzaf0d\" data-start=\"1003\" data-end=\"1087\"\u003e250A frame class protection for industrial fault levels (varies by system voltage)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"uvdx3z\" data-start=\"1089\" data-end=\"1111\"\u003eKey Specifications\u003c\/h3\u003e\n\u003cul data-start=\"1113\" data-end=\"1591\"\u003e\n\u003cli data-section-id=\"1rb54mn\" data-start=\"1113\" data-end=\"1163\"\u003eBreaker Type: Molded Case Circuit Breaker (MCCB)\u003c\/li\u003e\n\u003cli data-section-id=\"1h32kbn\" data-start=\"1164\" data-end=\"1186\"\u003eSeries: SENTRON 3VA6\u003c\/li\u003e\n\u003cli data-section-id=\"trojgn\" data-start=\"1187\" data-end=\"1200\"\u003eFamily: 3VA\u003c\/li\u003e\n\u003cli data-section-id=\"rij2e2\" data-start=\"1201\" data-end=\"1234\"\u003ePart Number: 3VA6225-8HN31-0AA0\u003c\/li\u003e\n\u003cli data-section-id=\"1upmcmo\" data-start=\"1235\" data-end=\"1260\"\u003eFrame Size: 3VA62 Frame\u003c\/li\u003e\n\u003cli data-section-id=\"1rq4rrm\" data-start=\"1261\" data-end=\"1286\"\u003eNumber of Poles: 3-Pole\u003c\/li\u003e\n\u003cli data-section-id=\"huvk1g\" data-start=\"1287\" data-end=\"1316\"\u003eMounting Style: Panel Mount\u003c\/li\u003e\n\u003cli data-section-id=\"yu9gvb\" data-start=\"1317\" data-end=\"1369\"\u003eTerminal Type: Lugs (not included where specified)\u003c\/li\u003e\n\u003cli data-section-id=\"1iwaxe3\" data-start=\"1370\" data-end=\"1422\"\u003eTrip Technology: Thermal Magnetic (fixed settings)\u003c\/li\u003e\n\u003cli data-section-id=\"hmzzb4\" data-start=\"1423\" data-end=\"1447\"\u003eTrip Function Code: LI\u003c\/li\u003e\n\u003cli data-section-id=\"zfxwru\" data-start=\"1448\" data-end=\"1503\"\u003eTrip Function: Long-Time and Instantaneous Protection\u003c\/li\u003e\n\u003cli data-section-id=\"i7wwfg\" data-start=\"1504\" data-end=\"1555\"\u003eTrip Adjustability: Fixed Thermal, Fixed Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"14p4nbv\" data-start=\"1556\" data-end=\"1591\"\u003eProtection Type: Thermal Magnetic\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"nucr17\" data-start=\"1593\" data-end=\"1621\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul data-start=\"1623\" data-end=\"1916\"\u003e\n\u003cli data-section-id=\"1vsgwjh\" data-start=\"1623\" data-end=\"1717\"\u003eBreaking Capacity Class: High interrupting capacity (Class H \/ very high fault level design)\u003c\/li\u003e\n\u003cli data-section-id=\"118h32z\" data-start=\"1718\" data-end=\"1770\"\u003eApplication: Industrial Power Distribution Systems\u003c\/li\u003e\n\u003cli data-section-id=\"zh6gxx\" data-start=\"1771\" data-end=\"1848\"\u003eCompatibility: Siemens 3VA Panelboards, Switchboards, Motor Control Centers\u003c\/li\u003e\n\u003cli data-section-id=\"ck9pzj\" data-start=\"1849\" data-end=\"1916\"\u003eConstruction Features: HACR Rated, Current Limiting, Reverse Feed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"nr5bwx\" data-start=\"1918\" data-end=\"1945\"\u003eStandards and Approvals\u003c\/h3\u003e\n\u003cul data-start=\"1947\" data-end=\"2034\"\u003e\n\u003cli data-section-id=\"b184r5\" data-start=\"1947\" data-end=\"1979\"\u003eStandards: IEC 60947-2, UL 489\u003c\/li\u003e\n\u003cli data-section-id=\"1riw5n8\" data-start=\"1980\" data-end=\"2034\"\u003eApprovals: CE, UL (region dependent), IEC compliance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1aljov1\" data-start=\"2036\" data-end=\"2052\"\u003eProduct Data\u003c\/h3\u003e\n\u003cul data-start=\"2054\" data-end=\"2134\"\u003e\n\u003cli data-section-id=\"1hicb8o\" data-start=\"2054\" data-end=\"2077\"\u003eManufacturer: Siemens\u003c\/li\u003e\n\u003cli data-section-id=\"1h32kbn\" data-start=\"2078\" data-end=\"2100\"\u003eSeries: SENTRON 3VA6\u003c\/li\u003e\n\u003cli data-section-id=\"rij2e2\" data-start=\"2101\" data-end=\"2134\"\u003ePart Number: 3VA6225-8HN31-0AA0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"wggvqn\" data-start=\"2136\" data-end=\"2152\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"2154\" data-end=\"2503\"\u003e\n\u003cli data-section-id=\"1oyak3f\" data-start=\"2154\" data-end=\"2193\"\u003eIndustrial Power Distribution Systems\u003c\/li\u003e\n\u003cli data-section-id=\"l0jetd\" data-start=\"2194\" data-end=\"2234\"\u003eHigh Fault Current Electrical Networks\u003c\/li\u003e\n\u003cli data-section-id=\"jcnaky\" data-start=\"2235\" data-end=\"2272\"\u003eCommercial Electrical Installations\u003c\/li\u003e\n\u003cli data-section-id=\"1kjdcw\" data-start=\"2273\" data-end=\"2303\"\u003ePanelboards and Switchboards\u003c\/li\u003e\n\u003cli data-section-id=\"8cw9ej\" data-start=\"2304\" data-end=\"2327\"\u003eMotor Control Centers\u003c\/li\u003e\n\u003cli data-section-id=\"eu036y\" data-start=\"2328\" data-end=\"2355\"\u003eFeeder Circuit Protection\u003c\/li\u003e\n\u003cli data-section-id=\"i24m9h\" data-start=\"2356\" data-end=\"2389\"\u003eCritical Infrastructure Systems\u003c\/li\u003e\n\u003cli data-section-id=\"1ae9zfb\" data-start=\"2390\" data-end=\"2426\"\u003eHeavy Industrial Load Distribution\u003c\/li\u003e\n\u003cli data-section-id=\"1mi8zrf\" data-start=\"2427\" data-end=\"2465\"\u003eHigh Short-Circuit Protection Panels\u003c\/li\u003e\n\u003cli data-section-id=\"12v7aaz\" data-start=\"2466\" data-end=\"2503\"\u003eCurrent-Limiting Protection Systems\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens \/ ITE","offers":[{"title":"NEW","offer_id":48491188551929,"sku":"3VA6225-8HN31-0AA0","price":2726.69,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/3VA5195-6ED31-0AA0-3-Pole-Circuit-Breaker_Siemens_1_cc0832b4-679f-4747-96e0-03916c75c93e.webp?v=1780752795","url":"https:\/\/mycircuitbreakers.com\/products\/siemens-3va6225-8hn31-0aa0-250-amp-3-pole-molded-case-circuit-breaker-panel-mount-high-interrupting-capacity-150ka-480vac","provider":"My Circuit Breakers","version":"1.0","type":"link"}