{"product_id":"siemens-3vae6001s-circuit-breaker-enclosure-400-600a-nema-1-surface-mount-for-3va5-3va6-frames-without-neutral","title":"Siemens 3VAE6001S Circuit Breaker Enclosure – 400–600A – NEMA 1 Surface Mount – For 3VA5 \/ 3VA6 Frames (Without Neutral)","description":"\u003cp data-start=\"146\" data-end=\"601\"\u003eThe Siemens 3VAE6001S is a low-voltage circuit breaker enclosure designed for Siemens 3VA molded case circuit breakers. It is intended for use with 400–600A 3VA5 and 3VA6 frame UL circuit breakers, providing a secure and standardized housing solution for electrical distribution equipment. This enclosure is configured without a neutral and is suitable for indoor applications requiring reliable mounting and protection of MCCB devices.\u003c\/p\u003e\n\u003ch3 data-section-id=\"yc43s8\" data-start=\"603\" data-end=\"625\"\u003eVoltage and Rating\u003c\/h3\u003e\n\u003cul data-start=\"627\" data-end=\"802\"\u003e\n\u003cli data-section-id=\"vo96xx\" data-start=\"627\" data-end=\"659\"\u003eCurrent Rating: 400–600 Amps\u003c\/li\u003e\n\u003cli data-section-id=\"s6nlmu\" data-start=\"660\" data-end=\"747\"\u003eVoltage Rating: Compatible with Siemens 3VA5 and 3VA6 frame circuit breaker systems\u003c\/li\u003e\n\u003cli data-section-id=\"1bqix5l\" data-start=\"748\" data-end=\"802\"\u003eEnclosure Rating: NEMA 1 (surface mount, indoor use)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"uvdx3z\" data-start=\"804\" data-end=\"826\"\u003eKey Specifications\u003c\/h3\u003e\n\u003cul data-start=\"828\" data-end=\"1100\"\u003e\n\u003cli data-section-id=\"13m1hqf\" data-start=\"828\" data-end=\"871\"\u003eProduct Type: Circuit Breaker Enclosure\u003c\/li\u003e\n\u003cli data-section-id=\"90uhhm\" data-start=\"872\" data-end=\"887\"\u003eSeries: 3VA\u003c\/li\u003e\n\u003cli data-section-id=\"qi30mg\" data-start=\"888\" data-end=\"913\"\u003eManufacturer: Siemens\u003c\/li\u003e\n\u003cli data-section-id=\"12pfnsk\" data-start=\"914\" data-end=\"940\"\u003ePart Number: 3VAE6001S\u003c\/li\u003e\n\u003cli data-section-id=\"10k21t5\" data-start=\"941\" data-end=\"998\"\u003eFrame Compatibility: 3VA5 (400–600A), 3VA6 (400–600A)\u003c\/li\u003e\n\u003cli data-section-id=\"1ey65sn\" data-start=\"999\" data-end=\"1032\"\u003eMounting Style: Surface mount\u003c\/li\u003e\n\u003cli data-section-id=\"10iw2ux\" data-start=\"1033\" data-end=\"1061\"\u003eNeutral: Without neutral\u003c\/li\u003e\n\u003cli data-section-id=\"hm14f3\" data-start=\"1062\" data-end=\"1100\"\u003eApplication: MCCB enclosure system\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"nucr17\" data-start=\"1102\" data-end=\"1130\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul data-start=\"1132\" data-end=\"1458\"\u003e\n\u003cli data-section-id=\"16yidgk\" data-start=\"1132\" data-end=\"1190\"\u003eDesigned For: Siemens 3VA molded case circuit breakers\u003c\/li\u003e\n\u003cli data-section-id=\"g1ifqm\" data-start=\"1191\" data-end=\"1246\"\u003eInstallation Type: Indoor surface-mounted enclosure\u003c\/li\u003e\n\u003cli data-section-id=\"1xc9n5\" data-start=\"1247\" data-end=\"1305\"\u003eApplication Use: Electrical power distribution systems\u003c\/li\u003e\n\u003cli data-section-id=\"11l6q0v\" data-start=\"1306\" data-end=\"1386\"\u003eEnvironmental Protection: Basic indoor protection against accidental contact\u003c\/li\u003e\n\u003cli data-section-id=\"tw3tyw\" data-start=\"1387\" data-end=\"1458\"\u003eConstruction Purpose: Secure housing for circuit breaker assemblies\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"nr5bwx\" data-start=\"1460\" data-end=\"1487\"\u003eStandards and Approvals\u003c\/h3\u003e\n\u003cul data-start=\"1489\" data-end=\"1596\"\u003e\n\u003cli data-section-id=\"xk878o\" data-start=\"1489\" data-end=\"1515\"\u003eApproval: CSA Approved\u003c\/li\u003e\n\u003cli data-section-id=\"1fgemo1\" data-start=\"1516\" data-end=\"1542\"\u003eEnclosure Type: NEMA 1\u003c\/li\u003e\n\u003cli data-section-id=\"lp2u78\" data-start=\"1543\" data-end=\"1596\"\u003eProduct Category: 3VA UL breaker enclosure system\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1aljov1\" data-start=\"1598\" data-end=\"1614\"\u003eProduct Data\u003c\/h3\u003e\n\u003cul data-start=\"1616\" data-end=\"1702\"\u003e\n\u003cli data-section-id=\"qi30mg\" data-start=\"1616\" data-end=\"1641\"\u003eManufacturer: Siemens\u003c\/li\u003e\n\u003cli data-section-id=\"90uhhm\" data-start=\"1642\" data-end=\"1657\"\u003eSeries: 3VA\u003c\/li\u003e\n\u003cli data-section-id=\"12pfnsk\" data-start=\"1658\" data-end=\"1684\"\u003ePart Number: 3VAE6001S\u003c\/li\u003e\n\u003cli data-section-id=\"1c3k2wq\" data-start=\"1685\" data-end=\"1702\"\u003eWeight: 2 lbs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"wggvqn\" data-start=\"1704\" data-end=\"1720\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"1722\" data-end=\"2087\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\n\u003cli data-section-id=\"yi6n97\" data-start=\"1722\" data-end=\"1763\"\u003eIndustrial Power Distribution Systems\u003c\/li\u003e\n\u003cli data-section-id=\"1cfavo2\" data-start=\"1764\" data-end=\"1803\"\u003eCommercial Electrical Installations\u003c\/li\u003e\n\u003cli data-section-id=\"1p2acdc\" data-start=\"1804\" data-end=\"1836\"\u003eSwitchboards and Panelboards\u003c\/li\u003e\n\u003cli data-section-id=\"a5hesb\" data-start=\"1837\" data-end=\"1862\"\u003eMotor Control Centers\u003c\/li\u003e\n\u003cli data-section-id=\"245dtf\" data-start=\"1863\" data-end=\"1901\"\u003eCircuit Breaker Mounting Solutions\u003c\/li\u003e\n\u003cli data-section-id=\"10x4tzr\" data-start=\"1902\" data-end=\"1938\"\u003eIndoor Electrical Infrastructure\u003c\/li\u003e\n\u003cli data-section-id=\"cjkkzu\" data-start=\"1939\" data-end=\"1971\"\u003eElectrical Equipment Housing\u003c\/li\u003e\n\u003cli data-section-id=\"14xe83w\" data-start=\"1972\" data-end=\"2006\"\u003eLow Voltage Protection Systems\u003c\/li\u003e\n\u003cli data-section-id=\"vctq4w\" data-start=\"2007\" data-end=\"2044\"\u003eFacility Power Management Systems\u003c\/li\u003e\n\u003cli data-section-id=\"1wcj789\" data-start=\"2045\" data-end=\"2087\" data-is-last-node=\"\"\u003eElectrical Retrofit and Upgrade Projects\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens \/ ITE","offers":[{"title":"NEW","offer_id":48491717165305,"sku":"3VAE6001S","price":912.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/3VAE125N1F-Enclosure_Siemens_1_a618ea00-d674-4386-ad25-2c841deb457f.webp?v=1780767629","url":"https:\/\/mycircuitbreakers.com\/products\/siemens-3vae6001s-circuit-breaker-enclosure-400-600a-nema-1-surface-mount-for-3va5-3va6-frames-without-neutral","provider":"My Circuit Breakers","version":"1.0","type":"link"}