{"product_id":"siemens-b2100h00s01-molded-case-circuit-breaker-100a-2-pole-120-240v-22kaic-factory-installed-120v-shunt-trip","title":"Siemens B2100H00S01 Molded Case Circuit Breaker – 100A – 2 Pole – 120\/240V – 22kAIC – Factory-Installed 120V Shunt Trip","description":"\u003cp data-start=\"141\" data-end=\"555\"\u003eThe Siemens B2100H00S01 is a BLH Series molded case circuit breaker designed to provide dependable overload and short-circuit protection in commercial and industrial electrical distribution systems. This 100A, two-pole breaker features a thermal magnetic trip mechanism with Long-Time and Instantaneous (LI) protection functions, ensuring reliable circuit protection and fast fault interruption.\u003c\/p\u003e\n\u003cp data-start=\"557\" data-end=\"853\"\u003eEquipped with a factory-installed 120V shunt trip, the breaker allows remote tripping capability for emergency shutdown, safety interlocking, and automated control applications. Its bolt-on mounting design provides secure installation in compatible Siemens panelboards and distribution equipment.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1yl5694\" data-start=\"855\" data-end=\"873\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-start=\"875\" data-end=\"1045\"\u003e\n\u003cli data-section-id=\"abfwkk\" data-start=\"875\" data-end=\"893\"\u003eBrand: Siemens\u003c\/li\u003e\n\u003cli data-section-id=\"a64g6r\" data-start=\"894\" data-end=\"928\"\u003eManufacturer: Siemens Breakers\u003c\/li\u003e\n\u003cli data-section-id=\"1u4wlcq\" data-start=\"929\" data-end=\"957\"\u003ePart Number: B2100H00S01\u003c\/li\u003e\n\u003cli data-section-id=\"wcmmie\" data-start=\"958\" data-end=\"979\"\u003eFamily: BL Series\u003c\/li\u003e\n\u003cli data-section-id=\"1joafpn\" data-start=\"980\" data-end=\"993\"\u003eType: BLH\u003c\/li\u003e\n\u003cli data-section-id=\"v89adw\" data-start=\"994\" data-end=\"1045\"\u003eCategory: Molded Case Circuit Breakers \/ 2-Pole\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1v2p98c\" data-start=\"1047\" data-end=\"1069\"\u003eElectrical Ratings\u003c\/h3\u003e\n\u003cul data-start=\"1071\" data-end=\"1341\"\u003e\n\u003cli data-section-id=\"19gbtl7\" data-start=\"1071\" data-end=\"1095\"\u003eCurrent Rating: 100A\u003c\/li\u003e\n\u003cli data-section-id=\"g1ar5q\" data-start=\"1096\" data-end=\"1123\"\u003eNumber of Poles: 2 Pole\u003c\/li\u003e\n\u003cli data-section-id=\"1hm5lfy\" data-start=\"1124\" data-end=\"1155\"\u003eVoltage Rating: 120\/240V AC\u003c\/li\u003e\n\u003cli data-section-id=\"vdhrok\" data-start=\"1156\" data-end=\"1174\"\u003ePhase: 1 Phase\u003c\/li\u003e\n\u003cli data-section-id=\"zmddk6\" data-start=\"1175\" data-end=\"1215\"\u003eInterrupting Capacity: 22kAIC @ 240V\u003c\/li\u003e\n\u003cli data-section-id=\"1vwficb\" data-start=\"1216\" data-end=\"1253\"\u003eProtection Type: Thermal Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"v7p51s\" data-start=\"1254\" data-end=\"1312\"\u003eFunctions: LI – Long-Time and Instantaneous Protection\u003c\/li\u003e\n\u003cli data-section-id=\"jbs3kp\" data-start=\"1313\" data-end=\"1341\"\u003eShunt Trip Voltage: 120V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1gqh9r7\" data-start=\"1343\" data-end=\"1372\"\u003eMechanical Specifications\u003c\/h3\u003e\n\u003cul data-start=\"1374\" data-end=\"1441\"\u003e\n\u003cli data-section-id=\"1ibps6a\" data-start=\"1374\" data-end=\"1402\"\u003eConnection Type: Bolt-On\u003c\/li\u003e\n\u003cli data-section-id=\"zxl4ip\" data-start=\"1403\" data-end=\"1441\"\u003eMounting Type: Panelboard Mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1dac35e\" data-start=\"1443\" data-end=\"1465\"\u003eTechnical Features\u003c\/h3\u003e\n\u003cul data-start=\"1467\" data-end=\"1817\"\u003e\n\u003cli data-section-id=\"1xj0njs\" data-start=\"1467\" data-end=\"1514\"\u003eFactory-installed 120V shunt trip accessory\u003c\/li\u003e\n\u003cli data-section-id=\"8y1z8j\" data-start=\"1515\" data-end=\"1565\"\u003eProvides overload and short-circuit protection\u003c\/li\u003e\n\u003cli data-section-id=\"1izdfj9\" data-start=\"1566\" data-end=\"1626\"\u003eThermal magnetic trip unit for dependable fault response\u003c\/li\u003e\n\u003cli data-section-id=\"amn819\" data-start=\"1627\" data-end=\"1689\"\u003eHigh 22kA interrupting capacity for demanding applications\u003c\/li\u003e\n\u003cli data-section-id=\"1hyne4f\" data-start=\"1690\" data-end=\"1758\"\u003eRemote trip capability for safety and emergency shutdown systems\u003c\/li\u003e\n\u003cli data-section-id=\"ugix7y\" data-start=\"1759\" data-end=\"1817\"\u003eDurable molded case construction for long service life\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"nr5bwx\" data-start=\"1819\" data-end=\"1846\"\u003eStandards and Approvals\u003c\/h3\u003e\n\u003cul data-start=\"1848\" data-end=\"1882\"\u003e\n\u003cli data-section-id=\"fjdscg\" data-start=\"1848\" data-end=\"1865\"\u003eUL 489 Listed\u003c\/li\u003e\n\u003cli data-section-id=\"3h4a0l\" data-start=\"1866\" data-end=\"1882\"\u003eCSA Approved\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"wggvqn\" data-start=\"1884\" data-end=\"1900\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"1902\" data-end=\"2167\"\u003e\n\u003cli data-section-id=\"ov2tsh\" data-start=\"1902\" data-end=\"1948\"\u003eCommercial electrical distribution systems\u003c\/li\u003e\n\u003cli data-section-id=\"1c8wqh4\" data-start=\"1949\" data-end=\"1989\"\u003eIndustrial power distribution panels\u003c\/li\u003e\n\u003cli data-section-id=\"k2nyb9\" data-start=\"1990\" data-end=\"2030\"\u003eBranch and feeder circuit protection\u003c\/li\u003e\n\u003cli data-section-id=\"1msvq3z\" data-start=\"2031\" data-end=\"2069\"\u003eEmergency power disconnect systems\u003c\/li\u003e\n\u003cli data-section-id=\"17iojjw\" data-start=\"2070\" data-end=\"2113\"\u003eBuilding automation and control systems\u003c\/li\u003e\n\u003cli data-section-id=\"13m4olu\" data-start=\"2114\" data-end=\"2167\"\u003eSafety interlock and remote shutdown applications\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens \/ ITE","offers":[{"title":"NEW","offer_id":48498453643513,"sku":"B2100H00S01","price":261.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/B2100H00S01-new-1_1e398aff-da41-4831-a42c-e9605f4ca025.jpg?v=1780925287","url":"https:\/\/mycircuitbreakers.com\/products\/siemens-b2100h00s01-molded-case-circuit-breaker-100a-2-pole-120-240v-22kaic-factory-installed-120v-shunt-trip","provider":"My Circuit Breakers","version":"1.0","type":"link"}