{"product_id":"siemens-b215gf-ground-fault-circuit-interrupter-gfci-circuit-breaker-15a-2-pole-240v-5ma-10kaic","title":"Siemens B215GF Ground Fault Circuit Interrupter (GFCI) Circuit Breaker – 15A – 2 Pole – 240V – 5mA – 10kAIC","description":"\u003cp data-start=\"129\" data-end=\"564\"\u003eThe Siemens B215GF is a bolt-on Ground Fault Circuit Interrupter (GFCI) circuit breaker designed to provide both overcurrent protection and personnel ground fault protection in commercial, residential, and light industrial electrical systems. This 15A, two-pole breaker combines thermal magnetic circuit protection with highly sensitive 5mA ground fault detection to help protect users from electrical shock hazards.\u003c\/p\u003e\n\u003cp data-start=\"566\" data-end=\"767\"\u003eFeaturing Long-Time and Instantaneous trip functions and a 10kA interrupting capacity, the B215GF delivers reliable circuit protection while meeting applications that require enhanced personnel safety.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1yl5694\" data-start=\"769\" data-end=\"787\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-start=\"789\" data-end=\"926\"\u003e\n\u003cli data-section-id=\"abfwkk\" data-start=\"789\" data-end=\"807\"\u003eBrand: Siemens\u003c\/li\u003e\n\u003cli data-section-id=\"a64g6r\" data-start=\"808\" data-end=\"842\"\u003eManufacturer: Siemens Breakers\u003c\/li\u003e\n\u003cli data-section-id=\"8novbo\" data-start=\"843\" data-end=\"866\"\u003ePart Number: B215GF\u003c\/li\u003e\n\u003cli data-section-id=\"zr7u7h\" data-start=\"867\" data-end=\"897\"\u003eCategory: Circuit Breakers\u003c\/li\u003e\n\u003cli data-section-id=\"1ibps6a\" data-start=\"898\" data-end=\"926\"\u003eConnection Type: Bolt-On\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1v2p98c\" data-start=\"928\" data-end=\"950\"\u003eElectrical Ratings\u003c\/h3\u003e\n\u003cul data-start=\"952\" data-end=\"1118\"\u003e\n\u003cli data-section-id=\"7u5c7y\" data-start=\"952\" data-end=\"975\"\u003eCurrent Rating: 15A\u003c\/li\u003e\n\u003cli data-section-id=\"g1ar5q\" data-start=\"976\" data-end=\"1003\"\u003eNumber of Poles: 2 Pole\u003c\/li\u003e\n\u003cli data-section-id=\"1f7fnci\" data-start=\"1004\" data-end=\"1031\"\u003eVoltage Rating: 240V AC\u003c\/li\u003e\n\u003cli data-section-id=\"vdhrok\" data-start=\"1032\" data-end=\"1050\"\u003ePhase: 1 Phase\u003c\/li\u003e\n\u003cli data-section-id=\"9fhvpq\" data-start=\"1051\" data-end=\"1084\"\u003eGround Fault Sensitivity: 5mA\u003c\/li\u003e\n\u003cli data-section-id=\"a87b6v\" data-start=\"1085\" data-end=\"1118\"\u003eInterrupting Capacity: 10kAIC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1dbai82\" data-start=\"1120\" data-end=\"1143\"\u003eProtection Features\u003c\/h3\u003e\n\u003cul data-start=\"1145\" data-end=\"1433\"\u003e\n\u003cli data-section-id=\"5m5j6y\" data-start=\"1145\" data-end=\"1199\"\u003eGround Fault Circuit Interrupter (GFCI) Protection\u003c\/li\u003e\n\u003cli data-section-id=\"opk28u\" data-start=\"1200\" data-end=\"1235\"\u003eThermal Magnetic Trip Mechanism\u003c\/li\u003e\n\u003cli data-section-id=\"1rf5hh2\" data-start=\"1236\" data-end=\"1269\"\u003eLong-Time Overload Protection\u003c\/li\u003e\n\u003cli data-section-id=\"ec01p4\" data-start=\"1270\" data-end=\"1312\"\u003eInstantaneous Short-Circuit Protection\u003c\/li\u003e\n\u003cli data-section-id=\"4xv118\" data-start=\"1313\" data-end=\"1370\"\u003ePersonnel protection against electrical shock hazards\u003c\/li\u003e\n\u003cli data-section-id=\"110dp6y\" data-start=\"1371\" data-end=\"1433\"\u003eGround fault detection and interruption at 5mA sensitivity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1dac35e\" data-start=\"1435\" data-end=\"1457\"\u003eTechnical Features\u003c\/h3\u003e\n\u003cul data-start=\"1459\" data-end=\"1718\"\u003e\n\u003cli data-section-id=\"58mg9l\" data-start=\"1459\" data-end=\"1510\"\u003eBolt-on mounting design for secure installation\u003c\/li\u003e\n\u003cli data-section-id=\"8aobiw\" data-start=\"1511\" data-end=\"1563\"\u003eIntegrated ground fault sensing and interruption\u003c\/li\u003e\n\u003cli data-section-id=\"123c2wo\" data-start=\"1564\" data-end=\"1608\"\u003eFast response to ground fault conditions\u003c\/li\u003e\n\u003cli data-section-id=\"1ypha2j\" data-start=\"1609\" data-end=\"1659\"\u003eReliable overload and short-circuit protection\u003c\/li\u003e\n\u003cli data-section-id=\"ugix7y\" data-start=\"1660\" data-end=\"1718\"\u003eDurable molded case construction for long service life\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"nr5bwx\" data-start=\"1720\" data-end=\"1747\"\u003eStandards and Approvals\u003c\/h3\u003e\n\u003cul data-start=\"1749\" data-end=\"1765\"\u003e\n\u003cli data-section-id=\"3h4a0l\" data-start=\"1749\" data-end=\"1765\"\u003eCSA Approved\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"wggvqn\" data-start=\"1767\" data-end=\"1783\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"1785\" data-end=\"2095\"\u003e\n\u003cli data-section-id=\"4u5rby\" data-start=\"1785\" data-end=\"1818\"\u003ePersonnel protection circuits\u003c\/li\u003e\n\u003cli data-section-id=\"ov2tsh\" data-start=\"1819\" data-end=\"1865\"\u003eCommercial electrical distribution systems\u003c\/li\u003e\n\u003cli data-section-id=\"10zuz28\" data-start=\"1866\" data-end=\"1916\"\u003eResidential and light industrial installations\u003c\/li\u003e\n\u003cli data-section-id=\"1c3aqxq\" data-start=\"1917\" data-end=\"1961\"\u003eReceptacle and branch circuit protection\u003c\/li\u003e\n\u003cli data-section-id=\"yo86gq\" data-start=\"1962\" data-end=\"1991\"\u003eHVAC equipment protection\u003c\/li\u003e\n\u003cli data-section-id=\"o7qv6x\" data-start=\"1992\" data-end=\"2037\"\u003eElectrical safety compliance applications\u003c\/li\u003e\n\u003cli data-section-id=\"2mat5o\" data-start=\"2038\" data-end=\"2095\"\u003eGround fault protection in wet or hazardous locations\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens \/ ITE","offers":[{"title":"NEW","offer_id":48498506268921,"sku":"B215GF","price":273.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/CB-BF215-1_96484e81-1fdc-4143-96b9-4f0ffe8821a9.webp?v=1780925828","url":"https:\/\/mycircuitbreakers.com\/products\/siemens-b215gf-ground-fault-circuit-interrupter-gfci-circuit-breaker-15a-2-pole-240v-5ma-10kaic","provider":"My Circuit Breakers","version":"1.0","type":"link"}