{"product_id":"siemens-b220gfh-molded-case-circuit-breaker-blh-series-20a-2-pole-120-240v-5ma-class-a-gfci-22kaic-bolt-on","title":"Siemens B220GFH Molded Case Circuit Breaker – BLH Series – 20A – 2 Pole – 120\/240V – 5mA Class A GFCI – 22kAIC – Bolt-On","description":"\u003cp data-start=\"142\" data-end=\"514\"\u003eThe Siemens B220GFH is a BLH Series molded case circuit breaker designed for reliable overcurrent protection and high-sensitivity ground fault protection in commercial and industrial electrical systems. This 20A, two-pole breaker provides Class A 5mA personnel protection, making it suitable for applications where enhanced shock protection is required.\u003c\/p\u003e\n\u003cp data-start=\"516\" data-end=\"834\"\u003eEngineered for Siemens P1 through P5 panelboards, the B220GFH features a bolt-on mounting design and a pigtail neutral connection for secure and efficient installation. It incorporates thermal magnetic trip technology along with ground fault protection and a self-test function to ensure continuous operational safety.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1yl5694\" data-start=\"836\" data-end=\"854\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-start=\"856\" data-end=\"1000\"\u003e\n\u003cli data-section-id=\"abfwkk\" data-start=\"856\" data-end=\"874\"\u003eBrand: Siemens\u003c\/li\u003e\n\u003cli data-section-id=\"ai3q08\" data-start=\"875\" data-end=\"890\"\u003eSeries: BLH\u003c\/li\u003e\n\u003cli data-section-id=\"nlet2y\" data-start=\"891\" data-end=\"915\"\u003ePart Number: B220GFH\u003c\/li\u003e\n\u003cli data-section-id=\"gmiah5\" data-start=\"916\" data-end=\"948\"\u003eSpecial Classification: GFCI\u003c\/li\u003e\n\u003cli data-section-id=\"sybr12\" data-start=\"949\" data-end=\"976\"\u003eMounting Style: Bolt-On\u003c\/li\u003e\n\u003cli data-section-id=\"1nbdjus\" data-start=\"977\" data-end=\"1000\"\u003eTerminal Type: Lugs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1v2p98c\" data-start=\"1002\" data-end=\"1024\"\u003eElectrical Ratings\u003c\/h3\u003e\n\u003cul data-start=\"1026\" data-end=\"1209\"\u003e\n\u003cli data-section-id=\"ty4ke\" data-start=\"1026\" data-end=\"1043\"\u003eAmperage: 20A\u003c\/li\u003e\n\u003cli data-section-id=\"g1ar5q\" data-start=\"1044\" data-end=\"1071\"\u003eNumber of Poles: 2 Pole\u003c\/li\u003e\n\u003cli data-section-id=\"vdhrok\" data-start=\"1072\" data-end=\"1090\"\u003ePhase: 1 Phase\u003c\/li\u003e\n\u003cli data-section-id=\"1aud41a\" data-start=\"1091\" data-end=\"1121\"\u003eVoltage Rating: 120\/240VAC\u003c\/li\u003e\n\u003cli data-section-id=\"epx9xu\" data-start=\"1122\" data-end=\"1166\"\u003eInterrupting Capacity: 22kA @ 120\/240VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1f3lhq\" data-start=\"1167\" data-end=\"1209\"\u003eGround Fault Protection: 5mA (Class A)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"r3gfhz\" data-start=\"1211\" data-end=\"1235\"\u003eTrip Characteristics\u003c\/h3\u003e\n\u003cul data-start=\"1237\" data-end=\"1448\"\u003e\n\u003cli data-section-id=\"1b3baop\" data-start=\"1237\" data-end=\"1274\"\u003eTrip Technology: Thermal Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"123qyap\" data-start=\"1275\" data-end=\"1390\"\u003eTrip Function Code: LIG\n\u003cul data-start=\"1305\" data-end=\"1390\"\u003e\n\u003cli data-section-id=\"1w0lewu\" data-start=\"1305\" data-end=\"1329\"\u003eLong-Time Protection\u003c\/li\u003e\n\u003cli data-section-id=\"3rigus\" data-start=\"1332\" data-end=\"1360\"\u003eInstantaneous Protection\u003c\/li\u003e\n\u003cli data-section-id=\"uqme6b\" data-start=\"1363\" data-end=\"1390\"\u003eGround Fault Protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"rn4aoz\" data-start=\"1391\" data-end=\"1420\"\u003eTrip Adjustability: Fixed\u003c\/li\u003e\n\u003cli data-section-id=\"2nmzmn\" data-start=\"1421\" data-end=\"1448\"\u003eSelf-Test Function: Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"lsvziw\" data-start=\"1450\" data-end=\"1474\"\u003eWiring \u0026amp; Termination\u003c\/h3\u003e\n\u003cul data-start=\"1476\" data-end=\"1645\"\u003e\n\u003cli data-section-id=\"2bdok4\" data-start=\"1476\" data-end=\"1543\"\u003eWire Range:\n\u003cul data-start=\"1494\" data-end=\"1543\"\u003e\n\u003cli data-section-id=\"1a200j\" data-start=\"1494\" data-end=\"1516\"\u003e14–10 AWG (Copper)\u003c\/li\u003e\n\u003cli data-section-id=\"1gc8m3o\" data-start=\"1519\" data-end=\"1543\"\u003e12–10 AWG (Aluminum)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1xl7tnh\" data-start=\"1544\" data-end=\"1569\"\u003eMax Wire Size: 10 AWG\u003c\/li\u003e\n\u003cli data-section-id=\"f6n5sy\" data-start=\"1570\" data-end=\"1613\"\u003eMin Wire Size: 14 AWG (Cu), 12 AWG (Al)\u003c\/li\u003e\n\u003cli data-section-id=\"1lou7lk\" data-start=\"1614\" data-end=\"1645\"\u003eNeutral: Pigtail connection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"purqi0\" data-start=\"1647\" data-end=\"1664\"\u003eCompatibility\u003c\/h3\u003e\n\u003cul data-start=\"1666\" data-end=\"1751\"\u003e\n\u003cli data-section-id=\"11wjj97\" data-start=\"1666\" data-end=\"1722\"\u003eFor Use With: Siemens P1, P2, P3, P4, P5 panelboards\u003c\/li\u003e\n\u003cli data-section-id=\"14asp83\" data-start=\"1723\" data-end=\"1751\"\u003eMounting: Bolt-on design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"nr5bwx\" data-start=\"1753\" data-end=\"1780\"\u003eStandards and Approvals\u003c\/h3\u003e\n\u003cul data-start=\"1782\" data-end=\"1855\"\u003e\n\u003cli data-section-id=\"j8lt5v\" data-start=\"1782\" data-end=\"1792\"\u003eUL 489\u003c\/li\u003e\n\u003cli data-section-id=\"jiwcmg\" data-start=\"1793\" data-end=\"1803\"\u003eUL 943\u003c\/li\u003e\n\u003cli data-section-id=\"1kuinwb\" data-start=\"1804\" data-end=\"1823\"\u003eCSA C22.2 No. 5\u003c\/li\u003e\n\u003cli data-section-id=\"3h4a0l\" data-start=\"1824\" data-end=\"1840\"\u003eCSA Approved\u003c\/li\u003e\n\u003cli data-section-id=\"mq9pch\" data-start=\"1841\" data-end=\"1855\"\u003eHACR Rated\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1dac35e\" data-start=\"1857\" data-end=\"1879\"\u003eTechnical Features\u003c\/h3\u003e\n\u003cul data-start=\"1881\" data-end=\"2181\"\u003e\n\u003cli data-section-id=\"1ro12tf\" data-start=\"1881\" data-end=\"1922\"\u003eClass A 5mA personnel GFCI protection\u003c\/li\u003e\n\u003cli data-section-id=\"1248oou\" data-start=\"1923\" data-end=\"1966\"\u003eThermal magnetic overcurrent protection\u003c\/li\u003e\n\u003cli data-section-id=\"8zgc8j\" data-start=\"1967\" data-end=\"2006\"\u003eHigh interrupting capacity (22kAIC)\u003c\/li\u003e\n\u003cli data-section-id=\"1qm77a7\" data-start=\"2007\" data-end=\"2041\"\u003eSelf-test safety functionality\u003c\/li\u003e\n\u003cli data-section-id=\"132joeg\" data-start=\"2042\" data-end=\"2092\"\u003eHACR-rated construction for HVAC compatibility\u003c\/li\u003e\n\u003cli data-section-id=\"11keel0\" data-start=\"2093\" data-end=\"2142\"\u003eDurable molded case design for industrial use\u003c\/li\u003e\n\u003cli data-section-id=\"1p61tp4\" data-start=\"2143\" data-end=\"2181\"\u003eSecure bolt-on installation system\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"wggvqn\" data-start=\"2183\" data-end=\"2199\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"2201\" data-end=\"2504\"\u003e\n\u003cli data-section-id=\"ov2tsh\" data-start=\"2201\" data-end=\"2247\"\u003eCommercial electrical distribution systems\u003c\/li\u003e\n\u003cli data-section-id=\"159guef\" data-start=\"2248\" data-end=\"2284\"\u003eIndustrial power panels and MCCs\u003c\/li\u003e\n\u003cli data-section-id=\"zb41h7\" data-start=\"2285\" data-end=\"2333\"\u003ePersonnel protection circuits (Class A GFCI)\u003c\/li\u003e\n\u003cli data-section-id=\"1blfms6\" data-start=\"2334\" data-end=\"2369\"\u003eHVAC and motor-driven equipment\u003c\/li\u003e\n\u003cli data-section-id=\"86gwsc\" data-start=\"2370\" data-end=\"2414\"\u003eWet or high-risk electrical environments\u003c\/li\u003e\n\u003cli data-section-id=\"2mppzn\" data-start=\"2415\" data-end=\"2459\"\u003eBranch circuit protection in panelboards\u003c\/li\u003e\n\u003cli data-section-id=\"tgg0wk\" data-start=\"2460\" data-end=\"2504\"\u003eSafety-critical electrical installations\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens \/ ITE","offers":[{"title":"NEW","offer_id":48499762069753,"sku":"B220GFH","price":399.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/B220GFH2PoleGroundFaultCircuitBreaker_Siemens-01.webp?v=1780930925","url":"https:\/\/mycircuitbreakers.com\/products\/siemens-b220gfh-molded-case-circuit-breaker-blh-series-20a-2-pole-120-240v-5ma-class-a-gfci-22kaic-bolt-on","provider":"My Circuit Breakers","version":"1.0","type":"link"}