{"product_id":"siemens-bf115ah-molded-case-circuit-breaker-bl-series-15a-1-pole-120v-gfci-22kaic-bolt-on","title":"Siemens BF115AH Molded Case Circuit Breaker – BL Series – 15A – 1 Pole – 120V – GFCI – 22kAIC – Bolt-On","description":"\u003cp data-start=\"125\" data-end=\"558\"\u003eThe Siemens BF115AH is a BL Series molded case circuit breaker featuring integrated Ground Fault Circuit Interrupter (GFCI) protection for personnel safety and reliable overcurrent protection. This 15A, single-pole breaker utilizes thermal magnetic trip technology with Long-Time and Instantaneous (LI) trip functions to provide dependable protection against overloads, short circuits, and ground fault conditions.\u003c\/p\u003e\n\u003cp data-start=\"560\" data-end=\"821\"\u003eDesigned for bolt-on installation in Siemens panelboards, the BF115AH offers a high interrupting capacity of 22kA at 120V, making it suitable for commercial and industrial electrical distribution systems requiring enhanced fault protection and personnel safety.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1yl5694\" data-start=\"823\" data-end=\"841\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-start=\"843\" data-end=\"1057\"\u003e\n\u003cli data-section-id=\"abfwkk\" data-start=\"843\" data-end=\"861\"\u003eBrand: Siemens\u003c\/li\u003e\n\u003cli data-section-id=\"qi30mg\" data-start=\"862\" data-end=\"887\"\u003eManufacturer: Siemens\u003c\/li\u003e\n\u003cli data-section-id=\"10guw8p\" data-start=\"888\" data-end=\"912\"\u003ePart Number: BF115AH\u003c\/li\u003e\n\u003cli data-section-id=\"9vkwqj\" data-start=\"913\" data-end=\"934\"\u003eSeries: BL Series\u003c\/li\u003e\n\u003cli data-section-id=\"14e1bi7\" data-start=\"935\" data-end=\"950\"\u003eType: BLHF2\u003c\/li\u003e\n\u003cli data-section-id=\"1av37yh\" data-start=\"951\" data-end=\"1001\"\u003eProduct Type: GFCI Molded Case Circuit Breaker\u003c\/li\u003e\n\u003cli data-section-id=\"sybr12\" data-start=\"1002\" data-end=\"1029\"\u003eMounting Style: Bolt-On\u003c\/li\u003e\n\u003cli data-section-id=\"14t2wmy\" data-start=\"1030\" data-end=\"1057\"\u003ePanelboard Mounted: Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1v2p98c\" data-start=\"1059\" data-end=\"1081\"\u003eElectrical Ratings\u003c\/h3\u003e\n\u003cul data-start=\"1083\" data-end=\"1313\"\u003e\n\u003cli data-section-id=\"7u5c7y\" data-start=\"1083\" data-end=\"1106\"\u003eCurrent Rating: 15A\u003c\/li\u003e\n\u003cli data-section-id=\"d5dst9\" data-start=\"1107\" data-end=\"1134\"\u003eNumber of Poles: 1 Pole\u003c\/li\u003e\n\u003cli data-section-id=\"13l1xmf\" data-start=\"1135\" data-end=\"1162\"\u003eVoltage Rating: 120V AC\u003c\/li\u003e\n\u003cli data-section-id=\"vdhrok\" data-start=\"1163\" data-end=\"1181\"\u003ePhase: 1 Phase\u003c\/li\u003e\n\u003cli data-section-id=\"12uv83n\" data-start=\"1182\" data-end=\"1222\"\u003eInterrupting Capacity: 22kAIC @ 120V\u003c\/li\u003e\n\u003cli data-section-id=\"1vwficb\" data-start=\"1223\" data-end=\"1260\"\u003eProtection Type: Thermal Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"12stum6\" data-start=\"1261\" data-end=\"1313\"\u003eTrip Functions: Long-Time and Instantaneous (LI)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1dbai82\" data-start=\"1315\" data-end=\"1338\"\u003eProtection Features\u003c\/h3\u003e\n\u003cul data-start=\"1340\" data-end=\"1537\"\u003e\n\u003cli data-section-id=\"5m5j6y\" data-start=\"1340\" data-end=\"1394\"\u003eGround Fault Circuit Interrupter (GFCI) Protection\u003c\/li\u003e\n\u003cli data-section-id=\"9tm15t\" data-start=\"1395\" data-end=\"1448\"\u003ePersonnel protection against ground fault hazards\u003c\/li\u003e\n\u003cli data-section-id=\"1hecu90\" data-start=\"1449\" data-end=\"1472\"\u003eOverload protection\u003c\/li\u003e\n\u003cli data-section-id=\"1ga7cu8\" data-start=\"1473\" data-end=\"1501\"\u003eShort-circuit protection\u003c\/li\u003e\n\u003cli data-section-id=\"1hyndz2\" data-start=\"1502\" data-end=\"1537\"\u003eThermal magnetic trip mechanism\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1dac35e\" data-start=\"1539\" data-end=\"1561\"\u003eTechnical Features\u003c\/h3\u003e\n\u003cul data-start=\"1563\" data-end=\"1847\"\u003e\n\u003cli data-section-id=\"14qa6jr\" data-start=\"1563\" data-end=\"1620\"\u003eHigh interrupting capacity for demanding applications\u003c\/li\u003e\n\u003cli data-section-id=\"xhpcjv\" data-start=\"1621\" data-end=\"1665\"\u003eBolt-on mounting for secure installation\u003c\/li\u003e\n\u003cli data-section-id=\"d44t0g\" data-start=\"1666\" data-end=\"1704\"\u003eLoad-side lug terminal connections\u003c\/li\u003e\n\u003cli data-section-id=\"10wcoia\" data-start=\"1705\" data-end=\"1741\"\u003ePanelboard-mounted configuration\u003c\/li\u003e\n\u003cli data-section-id=\"3fp7te\" data-start=\"1742\" data-end=\"1785\"\u003eReliable fault sensing and interruption\u003c\/li\u003e\n\u003cli data-section-id=\"1a12iz3\" data-start=\"1786\" data-end=\"1847\"\u003eDesigned for commercial and industrial electrical systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"t1jf4\" data-start=\"1849\" data-end=\"1881\"\u003eEnvironmental Specifications\u003c\/h3\u003e\n\u003cul data-start=\"1883\" data-end=\"1919\"\u003e\n\u003cli data-section-id=\"1lgaldd\" data-start=\"1883\" data-end=\"1919\"\u003eAmbient Temperature Rating: 40°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"nr5bwx\" data-start=\"1921\" data-end=\"1948\"\u003eStandards and Approvals\u003c\/h3\u003e\n\u003cul data-start=\"1950\" data-end=\"1963\"\u003e\n\u003cli data-section-id=\"11a7gqd\" data-start=\"1950\" data-end=\"1963\"\u003eUL Listed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"wggvqn\" data-start=\"1965\" data-end=\"1981\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"1983\" data-end=\"2238\"\u003e\n\u003cli data-section-id=\"ov2tsh\" data-start=\"1983\" data-end=\"2029\"\u003eCommercial electrical distribution systems\u003c\/li\u003e\n\u003cli data-section-id=\"ah30i2\" data-start=\"2030\" data-end=\"2059\"\u003eIndustrial control panels\u003c\/li\u003e\n\u003cli data-section-id=\"1jabemj\" data-start=\"2060\" data-end=\"2089\"\u003eBranch circuit protection\u003c\/li\u003e\n\u003cli data-section-id=\"fdqrfs\" data-start=\"2090\" data-end=\"2123\"\u003ePersonnel safety applications\u003c\/li\u003e\n\u003cli data-section-id=\"1wj1upc\" data-start=\"2124\" data-end=\"2161\"\u003eReceptacle and equipment circuits\u003c\/li\u003e\n\u003cli data-section-id=\"c2cubp\" data-start=\"2162\" data-end=\"2202\"\u003eGround fault protected installations\u003c\/li\u003e\n\u003cli data-section-id=\"11vtzrj\" data-start=\"2203\" data-end=\"2238\"\u003ePanelboard distribution systems\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens \/ ITE","offers":[{"title":"NEW","offer_id":48504469422329,"sku":"BF115AH","price":243.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/5555_8d65425f-bdb2-4615-9984-3124350723a3.webp?v=1781008412","url":"https:\/\/mycircuitbreakers.com\/products\/siemens-bf115ah-molded-case-circuit-breaker-bl-series-15a-1-pole-120v-gfci-22kaic-bolt-on","provider":"My Circuit Breakers","version":"1.0","type":"link"}