{"product_id":"siemens-bg330-molded-case-circuit-breaker-bg-series-30a-3-pole-240v-switching-neutral-10kaic-bolt-on","title":"Siemens BG330 Molded Case Circuit Breaker – BG Series – 30A – 3 Pole – 240V – Switching Neutral – 10kAIC – Bolt-On","description":"\u003cp data-start=\"136\" data-end=\"513\"\u003eThe Siemens BG330 is a BG Series molded case circuit breaker designed for specialized electrical distribution applications requiring switching neutral functionality. This 30A, three-pole breaker provides reliable circuit protection with thermal magnetic trip technology, delivering Long-Time and Instantaneous protection against overloads and short circuits.\u003c\/p\u003e\n\u003cp data-start=\"515\" data-end=\"784\"\u003eEngineered for panelboard mounting, the BG330 ensures safe and efficient operation in commercial and industrial environments. Its switching neutral feature allows simultaneous disconnection of neutral and phase conductors, improving circuit isolation and system safety.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1yl5694\" data-start=\"786\" data-end=\"804\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-start=\"806\" data-end=\"967\"\u003e\n\u003cli data-section-id=\"abfwkk\" data-start=\"806\" data-end=\"824\"\u003eBrand: Siemens\u003c\/li\u003e\n\u003cli data-section-id=\"a64g6r\" data-start=\"825\" data-end=\"859\"\u003eManufacturer: Siemens Breakers\u003c\/li\u003e\n\u003cli data-section-id=\"1xp1qgk\" data-start=\"860\" data-end=\"882\"\u003ePart Number: BG330\u003c\/li\u003e\n\u003cli data-section-id=\"6rxfsb\" data-start=\"883\" data-end=\"897\"\u003eSeries: BG\u003c\/li\u003e\n\u003cli data-section-id=\"1ssq2xt\" data-start=\"898\" data-end=\"939\"\u003eCategory: Molded Case Circuit Breaker\u003c\/li\u003e\n\u003cli data-section-id=\"sybr12\" data-start=\"940\" data-end=\"967\"\u003eMounting Style: Bolt-On\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1v2p98c\" data-start=\"969\" data-end=\"991\"\u003eElectrical Ratings\u003c\/h3\u003e\n\u003cul data-start=\"993\" data-end=\"1261\"\u003e\n\u003cli data-section-id=\"7spoqh\" data-start=\"993\" data-end=\"1016\"\u003eCurrent Rating: 30A\u003c\/li\u003e\n\u003cli data-section-id=\"qp2tzz\" data-start=\"1017\" data-end=\"1044\"\u003eNumber of Poles: 3 Pole\u003c\/li\u003e\n\u003cli data-section-id=\"1hm5lfy\" data-start=\"1045\" data-end=\"1076\"\u003eVoltage Rating: 120\/240V AC\u003c\/li\u003e\n\u003cli data-section-id=\"pvjmxy\" data-start=\"1077\" data-end=\"1095\"\u003ePhase: 3 Phase\u003c\/li\u003e\n\u003cli data-section-id=\"1bddc9n\" data-start=\"1096\" data-end=\"1140\"\u003eInterrupting Capacity: 10kAIC @ 120\/240V\u003c\/li\u003e\n\u003cli data-section-id=\"1vwficb\" data-start=\"1141\" data-end=\"1178\"\u003eProtection Type: Thermal Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"12stum6\" data-start=\"1179\" data-end=\"1231\"\u003eTrip Functions: Long-Time and Instantaneous (LI)\u003c\/li\u003e\n\u003cli data-section-id=\"rn4aoz\" data-start=\"1232\" data-end=\"1261\"\u003eTrip Adjustability: Fixed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1dac35e\" data-start=\"1263\" data-end=\"1285\"\u003eTechnical Features\u003c\/h3\u003e\n\u003cul data-start=\"1287\" data-end=\"1584\"\u003e\n\u003cli data-section-id=\"1h2nfw1\" data-start=\"1287\" data-end=\"1353\"\u003eSwitching neutral functionality for improved circuit isolation\u003c\/li\u003e\n\u003cli data-section-id=\"tzhnnd\" data-start=\"1354\" data-end=\"1393\"\u003eCommon trip mechanism for all poles\u003c\/li\u003e\n\u003cli data-section-id=\"1kou47w\" data-start=\"1394\" data-end=\"1432\"\u003eThermal magnetic protection system\u003c\/li\u003e\n\u003cli data-section-id=\"12xv7cs\" data-start=\"1433\" data-end=\"1463\"\u003ePanelboard mounting design\u003c\/li\u003e\n\u003cli data-section-id=\"1pnmgw3\" data-start=\"1464\" data-end=\"1523\"\u003eReliable operation in commercial and industrial systems\u003c\/li\u003e\n\u003cli data-section-id=\"2i1up4\" data-start=\"1524\" data-end=\"1584\"\u003eDesigned for special application electrical distribution\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"135kd38\" data-start=\"1586\" data-end=\"1611\"\u003eWiring Specifications\u003c\/h3\u003e\n\u003cul data-start=\"1613\" data-end=\"1675\"\u003e\n\u003cli data-section-id=\"1jup81i\" data-start=\"1613\" data-end=\"1675\"\u003eDesigned for copper\/aluminum conductors (system dependent)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"purqi0\" data-start=\"1677\" data-end=\"1694\"\u003eCompatibility\u003c\/h3\u003e\n\u003cul data-start=\"1696\" data-end=\"1740\"\u003e\n\u003cli data-section-id=\"8bq6hr\" data-start=\"1696\" data-end=\"1740\"\u003eFor Use With: Siemens panelboard systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"nr5bwx\" data-start=\"1742\" data-end=\"1769\"\u003eStandards and Approvals\u003c\/h3\u003e\n\u003cul data-start=\"1771\" data-end=\"1798\"\u003e\n\u003cli data-section-id=\"j8lt5v\" data-start=\"1771\" data-end=\"1781\"\u003eUL 489\u003c\/li\u003e\n\u003cli data-section-id=\"3h4a0l\" data-start=\"1782\" data-end=\"1798\"\u003eCSA Approved\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"wggvqn\" data-start=\"1800\" data-end=\"1816\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"1818\" data-end=\"2113\"\u003e\n\u003cli data-section-id=\"ov2tsh\" data-start=\"1818\" data-end=\"1864\"\u003eCommercial electrical distribution systems\u003c\/li\u003e\n\u003cli data-section-id=\"1w6ailz\" data-start=\"1865\" data-end=\"1891\"\u003eIndustrial panelboards\u003c\/li\u003e\n\u003cli data-section-id=\"d5tgoj\" data-start=\"1892\" data-end=\"1926\"\u003eThree-phase circuit protection\u003c\/li\u003e\n\u003cli data-section-id=\"fx61pf\" data-start=\"1927\" data-end=\"1976\"\u003eSystems requiring switching neutral operation\u003c\/li\u003e\n\u003cli data-section-id=\"1md9u55\" data-start=\"1977\" data-end=\"2019\"\u003eHVAC and mechanical equipment circuits\u003c\/li\u003e\n\u003cli data-section-id=\"k2nyb9\" data-start=\"2020\" data-end=\"2060\"\u003eBranch and feeder circuit protection\u003c\/li\u003e\n\u003cli data-section-id=\"1h562wx\" data-start=\"2061\" data-end=\"2113\"\u003eSpecialized electrical distribution applications\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens \/ ITE","offers":[{"title":"NEW","offer_id":48504566776057,"sku":"BG330","price":98.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/B215H00S01-new-1_7d9f325c-fb50-4a73-be6e-1b6b6372594f.jpg?v=1781011385","url":"https:\/\/mycircuitbreakers.com\/products\/siemens-bg330-molded-case-circuit-breaker-bg-series-30a-3-pole-240v-switching-neutral-10kaic-bolt-on","provider":"My Circuit Breakers","version":"1.0","type":"link"}