{"product_id":"siemens-gf325na-safety-switch-vbii-series-400a-3-pole-240vac-fused-general-duty-disconnect-nema-1-indoor-enclosure","title":"Siemens GF325NA Safety Switch – VBII Series – 400A – 3 Pole – 240VAC – Fused General Duty Disconnect – NEMA 1 Indoor Enclosure","description":"\u003cp data-start=\"148\" data-end=\"559\"\u003eThe Siemens GF325NA is a VBII Series general-duty fusible safety switch engineered for high-capacity power distribution, service entrance, and equipment isolation applications. Rated at 400A and 240VAC, this 3-pole switch features a 3-fuse configuration with a solid neutral, providing reliable circuit protection and disconnect functionality for commercial and industrial electrical systems.\u003c\/p\u003e\n\u003cp data-start=\"561\" data-end=\"899\"\u003eDesigned for indoor installations, the GF325NA is housed in a NEMA Type 1 enclosure and is service entrance labeled for added installation flexibility. With a short-circuit withstand rating of 100kA at 240V when used with properly rated fuses, this switch delivers dependable performance in demanding electrical distribution environments.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1yl5694\" data-start=\"901\" data-end=\"919\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-start=\"921\" data-end=\"1170\"\u003e\n\u003cli data-section-id=\"4aesb7\" data-start=\"921\" data-end=\"945\"\u003eBrand: Siemens \/ ITE\u003c\/li\u003e\n\u003cli data-section-id=\"jgnn5n\" data-start=\"946\" data-end=\"970\"\u003ePart Number: GF325NA\u003c\/li\u003e\n\u003cli data-section-id=\"1rq4mwx\" data-start=\"971\" data-end=\"994\"\u003eSeries: VBII Series\u003c\/li\u003e\n\u003cli data-section-id=\"1yk9ih8\" data-start=\"995\" data-end=\"1007\"\u003eType: GF\u003c\/li\u003e\n\u003cli data-section-id=\"ly2fqu\" data-start=\"1008\" data-end=\"1055\"\u003eCategory: Safety Switch \/ Disconnect Switch\u003c\/li\u003e\n\u003cli data-section-id=\"safov8\" data-start=\"1056\" data-end=\"1085\"\u003eDuty Rating: General Duty\u003c\/li\u003e\n\u003cli data-section-id=\"1qr232p\" data-start=\"1086\" data-end=\"1121\"\u003eEnclosure Type: NEMA 1 (Indoor)\u003c\/li\u003e\n\u003cli data-section-id=\"nxoewu\" data-start=\"1122\" data-end=\"1143\"\u003eFusibility: Fused\u003c\/li\u003e\n\u003cli data-section-id=\"1grtuiw\" data-start=\"1144\" data-end=\"1170\"\u003eNeutral: Solid Neutral\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1v2p98c\" data-start=\"1172\" data-end=\"1194\"\u003eElectrical Ratings\u003c\/h3\u003e\n\u003cul data-start=\"1196\" data-end=\"1362\"\u003e\n\u003cli data-section-id=\"1bfn19q\" data-start=\"1196\" data-end=\"1220\"\u003eCurrent Rating: 400A\u003c\/li\u003e\n\u003cli data-section-id=\"124hxn6\" data-start=\"1221\" data-end=\"1247\"\u003eVoltage Rating: 240VAC\u003c\/li\u003e\n\u003cli data-section-id=\"qp2tzz\" data-start=\"1248\" data-end=\"1275\"\u003eNumber of Poles: 3 Pole\u003c\/li\u003e\n\u003cli data-section-id=\"pvjmxy\" data-start=\"1276\" data-end=\"1294\"\u003ePhase: 3 Phase\u003c\/li\u003e\n\u003cli data-section-id=\"bz6gcx\" data-start=\"1295\" data-end=\"1362\"\u003eInterrupting Capacity: 100kA @ 240V (with properly rated fuses)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"19zqy0x\" data-start=\"1364\" data-end=\"1376\"\u003eFeatures\u003c\/h3\u003e\n\u003cul data-start=\"1378\" data-end=\"1704\"\u003e\n\u003cli data-section-id=\"1m67kqv\" data-start=\"1378\" data-end=\"1414\"\u003eGeneral-duty fused safety switch\u003c\/li\u003e\n\u003cli data-section-id=\"1pkfg8y\" data-start=\"1415\" data-end=\"1440\"\u003e3-pole, 3-fuse design\u003c\/li\u003e\n\u003cli data-section-id=\"1gw5qzb\" data-start=\"1441\" data-end=\"1472\"\u003eSolid neutral configuration\u003c\/li\u003e\n\u003cli data-section-id=\"dbtd\" data-start=\"1473\" data-end=\"1501\"\u003eService entrance labeled\u003c\/li\u003e\n\u003cli data-section-id=\"1gpwoh2\" data-start=\"1502\" data-end=\"1571\"\u003eSuitable for commercial and industrial power distribution systems\u003c\/li\u003e\n\u003cli data-section-id=\"vcd8wl\" data-start=\"1572\" data-end=\"1640\"\u003eProvides safe equipment isolation and manual disconnecting means\u003c\/li\u003e\n\u003cli data-section-id=\"1103tl\" data-start=\"1641\" data-end=\"1704\"\u003eHigh short-circuit withstand capability when properly fused\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"wm1u32\" data-start=\"1706\" data-end=\"1728\"\u003eHorsepower Ratings\u003c\/h3\u003e\n\u003cul data-start=\"1730\" data-end=\"1879\"\u003e\n\u003cli data-section-id=\"1nv3xb3\" data-start=\"1730\" data-end=\"1772\"\u003e1-Phase, 2-Wire (Standard Fuse): 15 HP\u003c\/li\u003e\n\u003cli data-section-id=\"dbm7st\" data-start=\"1773\" data-end=\"1815\"\u003e3-Phase, 3-Wire (Standard Fuse): 50 HP\u003c\/li\u003e\n\u003cli data-section-id=\"bi3w8\" data-start=\"1816\" data-end=\"1861\"\u003e3-Phase, 3-Wire (Time-Delay Fuse): 125 HP\u003c\/li\u003e\n\u003cli data-section-id=\"hrvlwu\" data-start=\"1862\" data-end=\"1879\"\u003e250VDC: 50 HP\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1uohfrv\" data-start=\"1881\" data-end=\"1897\"\u003eConstruction\u003c\/h3\u003e\n\u003cul data-start=\"1899\" data-end=\"2040\"\u003e\n\u003cli data-section-id=\"piqnyi\" data-start=\"1899\" data-end=\"1931\"\u003eNEMA Type 1 indoor enclosure\u003c\/li\u003e\n\u003cli data-section-id=\"1lwzbzf\" data-start=\"1932\" data-end=\"1975\"\u003eHeavy-duty enclosed switch construction\u003c\/li\u003e\n\u003cli data-section-id=\"1l1w7dj\" data-start=\"1976\" data-end=\"2040\"\u003eDesigned for long-term reliability in demanding applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"nr5bwx\" data-start=\"2042\" data-end=\"2069\"\u003eStandards and Approvals\u003c\/h3\u003e\n\u003cul data-start=\"2071\" data-end=\"2144\"\u003e\n\u003cli data-section-id=\"3h4a0l\" data-start=\"2071\" data-end=\"2087\"\u003eCSA Approved\u003c\/li\u003e\n\u003cli data-section-id=\"dxw6eo\" data-start=\"2088\" data-end=\"2114\"\u003eService Entrance Rated\u003c\/li\u003e\n\u003cli data-section-id=\"26q4wj\" data-start=\"2115\" data-end=\"2144\"\u003eSiemens Authentic Product\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"wggvqn\" data-start=\"2146\" data-end=\"2162\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"2164\" data-end=\"2472\"\u003e\n\u003cli data-section-id=\"1sbqzz4\" data-start=\"2164\" data-end=\"2205\"\u003eCommercial power distribution systems\u003c\/li\u003e\n\u003cli data-section-id=\"1kfy1m1\" data-start=\"2206\" data-end=\"2245\"\u003eIndustrial electrical installations\u003c\/li\u003e\n\u003cli data-section-id=\"1nf16e4\" data-start=\"2246\" data-end=\"2276\"\u003eService entrance equipment\u003c\/li\u003e\n\u003cli data-section-id=\"6ia6oy\" data-start=\"2277\" data-end=\"2324\"\u003eMotor disconnect and isolation applications\u003c\/li\u003e\n\u003cli data-section-id=\"euly96\" data-start=\"2325\" data-end=\"2355\"\u003eHVAC equipment disconnects\u003c\/li\u003e\n\u003cli data-section-id=\"hxl3vf\" data-start=\"2356\" data-end=\"2411\"\u003eEquipment maintenance and lockout\/tagout procedures\u003c\/li\u003e\n\u003cli data-section-id=\"154up8s\" data-start=\"2412\" data-end=\"2472\"\u003eElectrical feeder and branch circuit disconnecting means\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2474\" data-end=\"2723\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e \u003c\/p\u003e","brand":"Siemens \/ ITE","offers":[{"title":"NEW","offer_id":48508821012729,"sku":"GF325NA","price":1949.45,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/GF225NA-All-New-1_107d5b1b-ce7e-4ed1-9ba1-e32c43848952.avif?v=1781097120","url":"https:\/\/mycircuitbreakers.com\/products\/siemens-gf325na-safety-switch-vbii-series-400a-3-pole-240vac-fused-general-duty-disconnect-nema-1-indoor-enclosure","provider":"My Circuit Breakers","version":"1.0","type":"link"}