{"product_id":"siemens-hf361n-safety-switch-vbii-series-30a-3-pole-600vac-heavy-duty-fusible-disconnect-with-solid-neutral-nema-1-indoor-enclosure","title":"Siemens HF361N Safety Switch – VBII Series – 30A – 3 Pole – 600VAC – Heavy Duty Fusible Disconnect with Solid Neutral – NEMA 1 Indoor Enclosure","description":"\u003cp data-start=\"167\" data-end=\"555\"\u003eThe Siemens HF361N is a VBII Series heavy-duty fusible safety switch designed for reliable circuit isolation and overcurrent protection in industrial and commercial electrical systems. Rated at 30A and 600VAC, this 3-pole switch features a 3-fuse configuration with a solid neutral, ensuring safe and controlled disconnect operation for power distribution applications.\u003c\/p\u003e\n\u003cp data-start=\"557\" data-end=\"837\"\u003eHoused in a NEMA Type 1 indoor enclosure, the HF361N is intended for controlled environments where durable electrical isolation and equipment protection are required. Its heavy-duty construction provides dependable performance in service entrance and general distribution systems.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1yl5694\" data-start=\"839\" data-end=\"857\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-start=\"859\" data-end=\"1105\"\u003e\n\u003cli data-section-id=\"4aesb7\" data-start=\"859\" data-end=\"883\"\u003eBrand: Siemens \/ ITE\u003c\/li\u003e\n\u003cli data-section-id=\"wpid1x\" data-start=\"884\" data-end=\"907\"\u003ePart Number: HF361N\u003c\/li\u003e\n\u003cli data-section-id=\"1rq4mwx\" data-start=\"908\" data-end=\"931\"\u003eSeries: VBII Series\u003c\/li\u003e\n\u003cli data-section-id=\"1yk2kyr\" data-start=\"932\" data-end=\"944\"\u003eType: HF\u003c\/li\u003e\n\u003cli data-section-id=\"ly2fqu\" data-start=\"945\" data-end=\"992\"\u003eCategory: Safety Switch \/ Disconnect Switch\u003c\/li\u003e\n\u003cli data-section-id=\"1wptmdt\" data-start=\"993\" data-end=\"1020\"\u003eDuty Rating: Heavy Duty\u003c\/li\u003e\n\u003cli data-section-id=\"nxoewu\" data-start=\"1021\" data-end=\"1042\"\u003eFusibility: Fused\u003c\/li\u003e\n\u003cli data-section-id=\"1grtuiw\" data-start=\"1043\" data-end=\"1069\"\u003eNeutral: Solid Neutral\u003c\/li\u003e\n\u003cli data-section-id=\"1qr232p\" data-start=\"1070\" data-end=\"1105\"\u003eEnclosure Type: NEMA 1 (Indoor)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1v2p98c\" data-start=\"1107\" data-end=\"1129\"\u003eElectrical Ratings\u003c\/h3\u003e\n\u003cul data-start=\"1131\" data-end=\"1299\"\u003e\n\u003cli data-section-id=\"7spoqh\" data-start=\"1131\" data-end=\"1154\"\u003eCurrent Rating: 30A\u003c\/li\u003e\n\u003cli data-section-id=\"1t5slu\" data-start=\"1155\" data-end=\"1181\"\u003eVoltage Rating: 600VAC\u003c\/li\u003e\n\u003cli data-section-id=\"qp2tzz\" data-start=\"1182\" data-end=\"1209\"\u003eNumber of Poles: 3 Pole\u003c\/li\u003e\n\u003cli data-section-id=\"pvjmxy\" data-start=\"1210\" data-end=\"1228\"\u003ePhase: 3 Phase\u003c\/li\u003e\n\u003cli data-section-id=\"1yr4n7f\" data-start=\"1229\" data-end=\"1259\"\u003eFuse Configuration: 3-Fuse\u003c\/li\u003e\n\u003cli data-section-id=\"1jtuf0e\" data-start=\"1260\" data-end=\"1299\"\u003eInterrupting Capacity: 200kA @ 600V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"19zqy0x\" data-start=\"1301\" data-end=\"1313\"\u003eFeatures\u003c\/h3\u003e\n\u003cul data-start=\"1315\" data-end=\"1628\"\u003e\n\u003cli data-section-id=\"1tefo1d\" data-start=\"1315\" data-end=\"1351\"\u003eHeavy-duty fusible safety switch\u003c\/li\u003e\n\u003cli data-section-id=\"1ilv2x4\" data-start=\"1352\" data-end=\"1396\"\u003e3-pole, 3-fuse design with solid neutral\u003c\/li\u003e\n\u003cli data-section-id=\"gwz3y8\" data-start=\"1397\" data-end=\"1448\"\u003eHigh interrupting capacity for fault protection\u003c\/li\u003e\n\u003cli data-section-id=\"cftrhl\" data-start=\"1449\" data-end=\"1496\"\u003eSuitable for 600VAC industrial applications\u003c\/li\u003e\n\u003cli data-section-id=\"1341uu1\" data-start=\"1497\" data-end=\"1536\"\u003eReliable manual disconnecting means\u003c\/li\u003e\n\u003cli data-section-id=\"hmcbte\" data-start=\"1537\" data-end=\"1564\"\u003eIndoor NEMA 1 enclosure\u003c\/li\u003e\n\u003cli data-section-id=\"1szewjf\" data-start=\"1565\" data-end=\"1628\"\u003eDesigned for industrial and commercial distribution systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1uohfrv\" data-start=\"1630\" data-end=\"1646\"\u003eConstruction\u003c\/h3\u003e\n\u003cul data-start=\"1648\" data-end=\"1786\"\u003e\n\u003cli data-section-id=\"jeigbz\" data-start=\"1648\" data-end=\"1682\"\u003eSteel enclosure (NEMA 1 rated)\u003c\/li\u003e\n\u003cli data-section-id=\"mfebdg\" data-start=\"1683\" data-end=\"1717\"\u003eHeavy-duty switching mechanism\u003c\/li\u003e\n\u003cli data-section-id=\"1hbwl0w\" data-start=\"1718\" data-end=\"1748\"\u003eIndoor installation design\u003c\/li\u003e\n\u003cli data-section-id=\"tvb7vs\" data-start=\"1749\" data-end=\"1786\"\u003eIndustrial-grade electrical build\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"nr5bwx\" data-start=\"1788\" data-end=\"1815\"\u003eStandards and Approvals\u003c\/h3\u003e\n\u003cul data-start=\"1817\" data-end=\"1869\"\u003e\n\u003cli data-section-id=\"3h4a0l\" data-start=\"1817\" data-end=\"1833\"\u003eCSA Approved\u003c\/li\u003e\n\u003cli data-section-id=\"a0kzxg\" data-start=\"1834\" data-end=\"1869\"\u003eSiemens \/ ITE Authentic Product\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"wggvqn\" data-start=\"1871\" data-end=\"1887\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"1889\" data-end=\"2175\"\u003e\n\u003cli data-section-id=\"1g63lej\" data-start=\"1889\" data-end=\"1930\"\u003eIndustrial power distribution systems\u003c\/li\u003e\n\u003cli data-section-id=\"1nf16e4\" data-start=\"1931\" data-end=\"1961\"\u003eService entrance equipment\u003c\/li\u003e\n\u003cli data-section-id=\"12b8sj0\" data-start=\"1962\" data-end=\"2009\"\u003eMotor and equipment disconnect applications\u003c\/li\u003e\n\u003cli data-section-id=\"sk3mdu\" data-start=\"2010\" data-end=\"2049\"\u003eCommercial electrical installations\u003c\/li\u003e\n\u003cli data-section-id=\"ra7dqn\" data-start=\"2050\" data-end=\"2091\"\u003eHVAC systems and mechanical equipment\u003c\/li\u003e\n\u003cli data-section-id=\"1jm4qup\" data-start=\"2092\" data-end=\"2137\"\u003eMaintenance and lockout\/tagout procedures\u003c\/li\u003e\n\u003cli data-section-id=\"16a1wch\" data-start=\"2138\" data-end=\"2175\"\u003eIndoor electrical control systems\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens \/ ITE","offers":[{"title":"NEW","offer_id":48510286037241,"sku":"HF361N","price":324.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/HF361N-New-1_ef895811-3449-46fc-b870-a260293ac0c3.webp?v=1781110895","url":"https:\/\/mycircuitbreakers.com\/products\/siemens-hf361n-safety-switch-vbii-series-30a-3-pole-600vac-heavy-duty-fusible-disconnect-with-solid-neutral-nema-1-indoor-enclosure","provider":"My Circuit Breakers","version":"1.0","type":"link"}