{"product_id":"siemens-hf363n-safety-switch-hf-series-100a-3-pole-600vac-heavy-duty-fusible-disconnect-with-solid-neutral-nema-1-indoor-enclosure","title":"Siemens HF363N Safety Switch – HF Series – 100A – 3 Pole – 600VAC – Heavy Duty Fusible Disconnect with Solid Neutral – NEMA 1 Indoor Enclosure","description":"\u003cp data-start=\"166\" data-end=\"609\"\u003eThe Siemens HF363N is a heavy-duty fusible safety switch designed for reliable power isolation, equipment protection, and service disconnect applications in commercial, institutional, and industrial facilities. Rated at 100A and 600VAC, this 3-pole switch features a 4-wire configuration with a solid neutral, providing dependable switching performance and overcurrent protection when used with Class H, J, K, R, or T fuses.\u003c\/p\u003e\n\u003cp data-start=\"611\" data-end=\"930\"\u003eWith a high interrupting rating of 200kAIC at 600V, the HF363N delivers exceptional fault-current protection for demanding electrical distribution systems. Its NEMA Type 1 enclosure is intended for indoor installations, while the heavy-duty single-throw mechanism ensures long-term reliability in critical applications.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1yl5694\" data-start=\"932\" data-end=\"950\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-start=\"952\" data-end=\"1235\"\u003e\n\u003cli data-section-id=\"abfwkk\" data-start=\"952\" data-end=\"970\"\u003eBrand: Siemens\u003c\/li\u003e\n\u003cli data-section-id=\"wpjwif\" data-start=\"971\" data-end=\"994\"\u003ePart Number: HF363N\u003c\/li\u003e\n\u003cli data-section-id=\"qy5gfv\" data-start=\"995\" data-end=\"1016\"\u003eSeries: HF Series\u003c\/li\u003e\n\u003cli data-section-id=\"2fvjfi\" data-start=\"1017\" data-end=\"1035\"\u003eFrame Type: HF\u003c\/li\u003e\n\u003cli data-section-id=\"ly2fqu\" data-start=\"1036\" data-end=\"1083\"\u003eCategory: Safety Switch \/ Disconnect Switch\u003c\/li\u003e\n\u003cli data-section-id=\"1wptmdt\" data-start=\"1084\" data-end=\"1111\"\u003eDuty Rating: Heavy Duty\u003c\/li\u003e\n\u003cli data-section-id=\"1tpmoot\" data-start=\"1112\" data-end=\"1135\"\u003eFusibility: Fusible\u003c\/li\u003e\n\u003cli data-section-id=\"soz32i\" data-start=\"1136\" data-end=\"1167\"\u003eActuator Type: Single Throw\u003c\/li\u003e\n\u003cli data-section-id=\"8n1vgh\" data-start=\"1168\" data-end=\"1199\"\u003eContact Configuration: 3PST\u003c\/li\u003e\n\u003cli data-section-id=\"1qr232p\" data-start=\"1200\" data-end=\"1235\"\u003eEnclosure Type: NEMA 1 (Indoor)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1v2p98c\" data-start=\"1237\" data-end=\"1259\"\u003eElectrical Ratings\u003c\/h3\u003e\n\u003cul data-start=\"1261\" data-end=\"1424\"\u003e\n\u003cli data-section-id=\"19gbtl7\" data-start=\"1261\" data-end=\"1285\"\u003eCurrent Rating: 100A\u003c\/li\u003e\n\u003cli data-section-id=\"1t5slu\" data-start=\"1286\" data-end=\"1312\"\u003eVoltage Rating: 600VAC\u003c\/li\u003e\n\u003cli data-section-id=\"qp2tzz\" data-start=\"1313\" data-end=\"1340\"\u003eNumber of Poles: 3 Pole\u003c\/li\u003e\n\u003cli data-section-id=\"pvjmxy\" data-start=\"1341\" data-end=\"1359\"\u003ePhase: 3 Phase\u003c\/li\u003e\n\u003cli data-section-id=\"1y4szwx\" data-start=\"1360\" data-end=\"1382\"\u003eNumber of Wires: 4\u003c\/li\u003e\n\u003cli data-section-id=\"wnerdg\" data-start=\"1383\" data-end=\"1424\"\u003eInterrupting Capacity: 200kAIC @ 600V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1enw571\" data-start=\"1426\" data-end=\"1448\"\u003eFuse Compatibility\u003c\/h3\u003e\n\u003cul data-start=\"1450\" data-end=\"1539\"\u003e\n\u003cli data-section-id=\"1g4hfdr\" data-start=\"1450\" data-end=\"1467\"\u003eClass H Fuses\u003c\/li\u003e\n\u003cli data-section-id=\"jipyxp\" data-start=\"1468\" data-end=\"1485\"\u003eClass J Fuses\u003c\/li\u003e\n\u003cli data-section-id=\"mrh8v0\" data-start=\"1486\" data-end=\"1503\"\u003eClass K Fuses\u003c\/li\u003e\n\u003cli data-section-id=\"18wq77p\" data-start=\"1504\" data-end=\"1521\"\u003eClass R Fuses\u003c\/li\u003e\n\u003cli data-section-id=\"153nmdf\" data-start=\"1522\" data-end=\"1539\"\u003eClass T Fuses\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"19zqy0x\" data-start=\"1541\" data-end=\"1553\"\u003eFeatures\u003c\/h3\u003e\n\u003cul data-start=\"1555\" data-end=\"1858\"\u003e\n\u003cli data-section-id=\"1tefo1d\" data-start=\"1555\" data-end=\"1591\"\u003eHeavy-duty fusible safety switch\u003c\/li\u003e\n\u003cli data-section-id=\"12n1kox\" data-start=\"1592\" data-end=\"1643\"\u003e3-pole, 4-wire configuration with solid neutral\u003c\/li\u003e\n\u003cli data-section-id=\"wp03wg\" data-start=\"1644\" data-end=\"1682\"\u003eHigh 200kAIC interrupting capacity\u003c\/li\u003e\n\u003cli data-section-id=\"aa18n\" data-start=\"1683\" data-end=\"1715\"\u003eSurface-mounted installation\u003c\/li\u003e\n\u003cli data-section-id=\"3tg37f\" data-start=\"1716\" data-end=\"1755\"\u003eMechanical lug terminal connections\u003c\/li\u003e\n\u003cli data-section-id=\"165cv8w\" data-start=\"1756\" data-end=\"1801\"\u003eReliable single-throw operating mechanism\u003c\/li\u003e\n\u003cli data-section-id=\"12a9f4u\" data-start=\"1802\" data-end=\"1858\"\u003eDesigned for commercial and industrial power systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1uohfrv\" data-start=\"1860\" data-end=\"1876\"\u003eConstruction\u003c\/h3\u003e\n\u003cul data-start=\"1878\" data-end=\"2044\"\u003e\n\u003cli data-section-id=\"1vcvc1l\" data-start=\"1878\" data-end=\"1911\"\u003eNEMA 1 indoor steel enclosure\u003c\/li\u003e\n\u003cli data-section-id=\"1lb2bjn\" data-start=\"1912\" data-end=\"1957\"\u003eHeavy-duty industrial switching mechanism\u003c\/li\u003e\n\u003cli data-section-id=\"1avk4nc\" data-start=\"1958\" data-end=\"1982\"\u003eSurface-mount design\u003c\/li\u003e\n\u003cli data-section-id=\"ikzxzr\" data-start=\"1983\" data-end=\"2044\"\u003eEngineered for long service life and dependable operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"nr5bwx\" data-start=\"2046\" data-end=\"2073\"\u003eStandards and Approvals\u003c\/h3\u003e\n\u003cul data-start=\"2075\" data-end=\"2118\"\u003e\n\u003cli data-section-id=\"11a7gqd\" data-start=\"2075\" data-end=\"2088\"\u003eUL Listed\u003c\/li\u003e\n\u003cli data-section-id=\"26q4wj\" data-start=\"2089\" data-end=\"2118\"\u003eSiemens Authentic Product\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"rwm0ne\" data-start=\"2120\" data-end=\"2145\"\u003eEnvironmental Ratings\u003c\/h3\u003e\n\u003cul data-start=\"2147\" data-end=\"2187\"\u003e\n\u003cli data-section-id=\"oqset0\" data-start=\"2147\" data-end=\"2187\"\u003eOperating Temperature: -29°C to 85°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"wggvqn\" data-start=\"2189\" data-end=\"2205\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"2207\" data-end=\"2526\"\u003e\n\u003cli data-section-id=\"1sbqzz4\" data-start=\"2207\" data-end=\"2248\"\u003eCommercial power distribution systems\u003c\/li\u003e\n\u003cli data-section-id=\"1kfy1m1\" data-start=\"2249\" data-end=\"2288\"\u003eIndustrial electrical installations\u003c\/li\u003e\n\u003cli data-section-id=\"rpp9at\" data-start=\"2289\" data-end=\"2317\"\u003eInstitutional facilities\u003c\/li\u003e\n\u003cli data-section-id=\"12b8sj0\" data-start=\"2318\" data-end=\"2365\"\u003eMotor and equipment disconnect applications\u003c\/li\u003e\n\u003cli data-section-id=\"1nf16e4\" data-start=\"2366\" data-end=\"2396\"\u003eService entrance equipment\u003c\/li\u003e\n\u003cli data-section-id=\"a15grp\" data-start=\"2397\" data-end=\"2428\"\u003eHVAC and mechanical systems\u003c\/li\u003e\n\u003cli data-section-id=\"1b7ncf6\" data-start=\"2429\" data-end=\"2472\"\u003eLockout\/Tagout (LOTO) safety procedures\u003c\/li\u003e\n\u003cli data-section-id=\"1eoqlyy\" data-start=\"2473\" data-end=\"2526\"\u003eElectrical maintenance and isolation applications\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens \/ ITE","offers":[{"title":"NEW","offer_id":48510305403129,"sku":"HF363N","price":706.05,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/HF261-New-1_a288ead6-d3b3-4f55-a60d-c6b5d12e2e62.webp?v=1781112699","url":"https:\/\/mycircuitbreakers.com\/products\/siemens-hf363n-safety-switch-hf-series-100a-3-pole-600vac-heavy-duty-fusible-disconnect-with-solid-neutral-nema-1-indoor-enclosure","provider":"My Circuit Breakers","version":"1.0","type":"link"}