{"product_id":"siemens-hf364-safety-switch-hf-series-200a-3-pole-600vac-600vdc-heavy-duty-fusible-disconnect-nema-1-indoor-enclosure","title":"Siemens HF364 Safety Switch – HF Series – 200A – 3 Pole – 600VAC\/600VDC – Heavy Duty Fusible Disconnect – NEMA 1 Indoor Enclosure","description":"\u003cp data-start=\"153\" data-end=\"562\"\u003eThe Siemens HF364 is a heavy-duty fusible safety switch designed for reliable power isolation, overcurrent protection, and equipment disconnect applications in commercial and industrial electrical systems. Rated at 200A, this 3-pole, 3-wire switch supports up to 600VAC and 600VDC operation, providing dependable performance for demanding power distribution and motor control installations.\u003c\/p\u003e\n\u003cp data-start=\"564\" data-end=\"906\"\u003eThe HF364 utilizes Class H, J, K, R, and T fuses and features a rugged heavy-duty switching mechanism for superior durability and fault protection. Housed in a NEMA Type 1 indoor enclosure, this switch is ideal for indoor electrical rooms, manufacturing facilities, and industrial environments requiring safe and reliable disconnecting means.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1yl5694\" data-start=\"908\" data-end=\"926\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-start=\"928\" data-end=\"1236\"\u003e\n\u003cli data-section-id=\"4aesb7\" data-start=\"928\" data-end=\"952\"\u003eBrand: Siemens \/ ITE\u003c\/li\u003e\n\u003cli data-section-id=\"1ccfcvy\" data-start=\"953\" data-end=\"975\"\u003ePart Number: HF364\u003c\/li\u003e\n\u003cli data-section-id=\"qy5gfv\" data-start=\"976\" data-end=\"997\"\u003eSeries: HF Series\u003c\/li\u003e\n\u003cli data-section-id=\"1yk2kyr\" data-start=\"998\" data-end=\"1010\"\u003eType: HF\u003c\/li\u003e\n\u003cli data-section-id=\"ly2fqu\" data-start=\"1011\" data-end=\"1058\"\u003eCategory: Safety Switch \/ Disconnect Switch\u003c\/li\u003e\n\u003cli data-section-id=\"1wptmdt\" data-start=\"1059\" data-end=\"1086\"\u003eDuty Rating: Heavy Duty\u003c\/li\u003e\n\u003cli data-section-id=\"1tpmoot\" data-start=\"1087\" data-end=\"1110\"\u003eFusibility: Fusible\u003c\/li\u003e\n\u003cli data-section-id=\"uz3x5m\" data-start=\"1111\" data-end=\"1144\"\u003eFuse Class: H, J, K, R, and T\u003c\/li\u003e\n\u003cli data-section-id=\"1qr232p\" data-start=\"1145\" data-end=\"1180\"\u003eEnclosure Type: NEMA 1 (Indoor)\u003c\/li\u003e\n\u003cli data-section-id=\"12p6cw9\" data-start=\"1181\" data-end=\"1212\"\u003eConfiguration: Single Throw\u003c\/li\u003e\n\u003cli data-section-id=\"1mvp48k\" data-start=\"1213\" data-end=\"1236\"\u003eNeutral: No Neutral\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1v2p98c\" data-start=\"1238\" data-end=\"1260\"\u003eElectrical Ratings\u003c\/h3\u003e\n\u003cul data-start=\"1262\" data-end=\"1426\"\u003e\n\u003cli data-section-id=\"17jx6g8\" data-start=\"1262\" data-end=\"1286\"\u003eCurrent Rating: 200A\u003c\/li\u003e\n\u003cli data-section-id=\"1dki1hd\" data-start=\"1287\" data-end=\"1317\"\u003eVoltage Rating: 480\/600VAC\u003c\/li\u003e\n\u003cli data-section-id=\"101ruh4\" data-start=\"1318\" data-end=\"1351\"\u003eDC Voltage Rating: 250\/600VDC\u003c\/li\u003e\n\u003cli data-section-id=\"qp2tzz\" data-start=\"1352\" data-end=\"1379\"\u003eNumber of Poles: 3 Pole\u003c\/li\u003e\n\u003cli data-section-id=\"pvjmxy\" data-start=\"1380\" data-end=\"1398\"\u003ePhase: 3 Phase\u003c\/li\u003e\n\u003cli data-section-id=\"1pf0fsv\" data-start=\"1399\" data-end=\"1426\"\u003eNumber of Wires: 3 Wire\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"wm1u32\" data-start=\"1428\" data-end=\"1450\"\u003eHorsepower Ratings\u003c\/h3\u003e\n\u003cp data-start=\"1452\" data-end=\"1470\"\u003e\u003cstrong data-start=\"1452\" data-end=\"1470\"\u003eStandard Fuses\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1472\" data-end=\"1583\"\u003e\n\u003cli data-section-id=\"1x5wolm\" data-start=\"1472\" data-end=\"1499\"\u003e25 HP @ 480VAC, 1 Phase\u003c\/li\u003e\n\u003cli data-section-id=\"k0m6ui\" data-start=\"1500\" data-end=\"1527\"\u003e50 HP @ 480VAC, 3 Phase\u003c\/li\u003e\n\u003cli data-section-id=\"1hnusdg\" data-start=\"1528\" data-end=\"1555\"\u003e30 HP @ 600VAC, 1 Phase\u003c\/li\u003e\n\u003cli data-section-id=\"1b65aw3\" data-start=\"1556\" data-end=\"1583\"\u003e60 HP @ 600VAC, 3 Phase\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1585\" data-end=\"1613\"\u003e\u003cstrong data-start=\"1585\" data-end=\"1613\"\u003eMaximum Time-Delay Fuses\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1615\" data-end=\"1728\"\u003e\n\u003cli data-section-id=\"1qgkvc\" data-start=\"1615\" data-end=\"1642\"\u003e50 HP @ 480VAC, 1 Phase\u003c\/li\u003e\n\u003cli data-section-id=\"19zbd15\" data-start=\"1643\" data-end=\"1671\"\u003e125 HP @ 480VAC, 3 Phase\u003c\/li\u003e\n\u003cli data-section-id=\"1pbgd9e\" data-start=\"1672\" data-end=\"1699\"\u003e50 HP @ 600VAC, 1 Phase\u003c\/li\u003e\n\u003cli data-section-id=\"ydu8ep\" data-start=\"1700\" data-end=\"1728\"\u003e150 HP @ 600VAC, 3 Phase\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1730\" data-end=\"1744\"\u003e\u003cstrong data-start=\"1730\" data-end=\"1744\"\u003eDC Ratings\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1746\" data-end=\"1783\"\u003e\n\u003cli data-section-id=\"grecd1\" data-start=\"1746\" data-end=\"1764\"\u003e40 HP @ 250VDC\u003c\/li\u003e\n\u003cli data-section-id=\"1ryx2k5\" data-start=\"1765\" data-end=\"1783\"\u003e50 HP @ 600VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"19zqy0x\" data-start=\"1785\" data-end=\"1797\"\u003eFeatures\u003c\/h3\u003e\n\u003cul data-start=\"1799\" data-end=\"2109\"\u003e\n\u003cli data-section-id=\"1tefo1d\" data-start=\"1799\" data-end=\"1835\"\u003eHeavy-duty fusible safety switch\u003c\/li\u003e\n\u003cli data-section-id=\"o2vcwc\" data-start=\"1836\" data-end=\"1868\"\u003e3-pole, 3-wire configuration\u003c\/li\u003e\n\u003cli data-section-id=\"1d0hy4g\" data-start=\"1869\" data-end=\"1910\"\u003eAccepts Class H, J, K, R, and T fuses\u003c\/li\u003e\n\u003cli data-section-id=\"1by2dwk\" data-start=\"1911\" data-end=\"1932\"\u003eNo-neutral design\u003c\/li\u003e\n\u003cli data-section-id=\"165cv8w\" data-start=\"1933\" data-end=\"1978\"\u003eReliable single-throw operating mechanism\u003c\/li\u003e\n\u003cli data-section-id=\"1d1btta\" data-start=\"1979\" data-end=\"2039\"\u003eSuitable for high-capacity motor and feeder applications\u003c\/li\u003e\n\u003cli data-section-id=\"1kflesk\" data-start=\"2040\" data-end=\"2109\"\u003eDesigned for commercial and industrial power distribution systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1uohfrv\" data-start=\"2111\" data-end=\"2127\"\u003eConstruction\u003c\/h3\u003e\n\u003cul data-start=\"2129\" data-end=\"2295\"\u003e\n\u003cli data-section-id=\"1vcvc1l\" data-start=\"2129\" data-end=\"2162\"\u003eNEMA 1 indoor steel enclosure\u003c\/li\u003e\n\u003cli data-section-id=\"1lb2bjn\" data-start=\"2163\" data-end=\"2208\"\u003eHeavy-duty industrial switching mechanism\u003c\/li\u003e\n\u003cli data-section-id=\"9jaj0o\" data-start=\"2209\" data-end=\"2257\"\u003eRugged enclosed design for long service life\u003c\/li\u003e\n\u003cli data-section-id=\"1f0awaj\" data-start=\"2258\" data-end=\"2295\"\u003eSuitable for indoor installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"16isa0t\" data-start=\"2297\" data-end=\"2324\"\u003ePhysical Specifications\u003c\/h3\u003e\n\u003cul data-start=\"2326\" data-end=\"2378\"\u003e\n\u003cli data-section-id=\"1bsk59g\" data-start=\"2326\" data-end=\"2378\"\u003eDimensions: 31.07 in H × 16.98 in W × 12.33 in D\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"nr5bwx\" data-start=\"2380\" data-end=\"2407\"\u003eStandards and Approvals\u003c\/h3\u003e\n\u003cul data-start=\"2409\" data-end=\"2487\"\u003e\n\u003cli data-section-id=\"11a7gqd\" data-start=\"2409\" data-end=\"2422\"\u003eUL Listed\u003c\/li\u003e\n\u003cli data-section-id=\"a0kzxg\" data-start=\"2423\" data-end=\"2458\"\u003eSiemens \/ ITE Authentic Product\u003c\/li\u003e\n\u003cli data-section-id=\"c97iv1\" data-start=\"2459\" data-end=\"2487\"\u003eSpeedfax™ Listed Product\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"wggvqn\" data-start=\"2489\" data-end=\"2505\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"2507\" data-end=\"2817\"\u003e\n\u003cli data-section-id=\"1g63lej\" data-start=\"2507\" data-end=\"2548\"\u003eIndustrial power distribution systems\u003c\/li\u003e\n\u003cli data-section-id=\"sk3mdu\" data-start=\"2549\" data-end=\"2588\"\u003eCommercial electrical installations\u003c\/li\u003e\n\u003cli data-section-id=\"1uvwxtp\" data-start=\"2589\" data-end=\"2629\"\u003eMotor control and protection systems\u003c\/li\u003e\n\u003cli data-section-id=\"1nf16e4\" data-start=\"2630\" data-end=\"2660\"\u003eService entrance equipment\u003c\/li\u003e\n\u003cli data-section-id=\"oicrpo\" data-start=\"2661\" data-end=\"2689\"\u003eManufacturing facilities\u003c\/li\u003e\n\u003cli data-section-id=\"8lpg5f\" data-start=\"2690\" data-end=\"2741\"\u003eEquipment disconnect and isolation applications\u003c\/li\u003e\n\u003cli data-section-id=\"a15grp\" data-start=\"2742\" data-end=\"2773\"\u003eHVAC and mechanical systems\u003c\/li\u003e\n\u003cli data-section-id=\"1b7ncf6\" data-start=\"2774\" data-end=\"2817\"\u003eLockout\/Tagout (LOTO) safety procedures\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens \/ ITE","offers":[{"title":"NEW","offer_id":48510326341881,"sku":"HF364","price":768.15,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/HF263J-All-New-1_9838c58d-5f03-4662-b496-f8c852e094ae.webp?v=1781113462","url":"https:\/\/mycircuitbreakers.com\/products\/siemens-hf364-safety-switch-hf-series-200a-3-pole-600vac-600vdc-heavy-duty-fusible-disconnect-nema-1-indoor-enclosure","provider":"My Circuit Breakers","version":"1.0","type":"link"}