{"product_id":"siemens-hf364nr-safety-switch-vbii-series-200a-3-pole-600vac-heavy-duty-fusible-disconnect-with-solid-neutral-nema-3r-outdoor-enclosure","title":"Siemens HF364NR Safety Switch – VBII Series – 200A – 3 Pole – 600VAC – Heavy Duty Fusible Disconnect with Solid Neutral – NEMA 3R Outdoor Enclosure","description":"\u003cp data-start=\"171\" data-end=\"608\"\u003eThe Siemens HF364NR is a VBII Series heavy-duty fusible safety switch designed for reliable power isolation, equipment protection, and service disconnect applications in commercial and industrial electrical systems. Rated at 200A and 600VAC, this 3-pole switch features a 4-wire configuration with a solid neutral, providing dependable switching performance and enhanced protection when used with properly rated fuses.\u003c\/p\u003e\n\u003cp data-start=\"610\" data-end=\"986\"\u003eConstructed with a rugged NEMA Type 3R outdoor enclosure, the HF364NR is engineered to withstand outdoor environmental conditions while maintaining safe and reliable operation. Its high 200kA short-circuit current rating, heavy-duty single-throw mechanism, and durable steel construction make it an ideal choice for demanding power distribution and motor control applications.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1yl5694\" data-start=\"988\" data-end=\"1006\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-start=\"1008\" data-end=\"1408\"\u003e\n\u003cli data-section-id=\"abfwkk\" data-start=\"1008\" data-end=\"1026\"\u003eBrand: Siemens\u003c\/li\u003e\n\u003cli data-section-id=\"e1sr6q\" data-start=\"1027\" data-end=\"1051\"\u003ePart Number: HF364NR\u003c\/li\u003e\n\u003cli data-section-id=\"1rq4mwx\" data-start=\"1052\" data-end=\"1075\"\u003eSeries: VBII Series\u003c\/li\u003e\n\u003cli data-section-id=\"1qmz2dj\" data-start=\"1076\" data-end=\"1143\"\u003eType: VBII Enclosed Fusible Heavy Duty Low Voltage Single Throw\u003c\/li\u003e\n\u003cli data-section-id=\"ly2fqu\" data-start=\"1144\" data-end=\"1191\"\u003eCategory: Safety Switch \/ Disconnect Switch\u003c\/li\u003e\n\u003cli data-section-id=\"1wptmdt\" data-start=\"1192\" data-end=\"1219\"\u003eDuty Rating: Heavy Duty\u003c\/li\u003e\n\u003cli data-section-id=\"1tpmoot\" data-start=\"1220\" data-end=\"1243\"\u003eFusibility: Fusible\u003c\/li\u003e\n\u003cli data-section-id=\"tlbff1\" data-start=\"1244\" data-end=\"1282\"\u003eContact Configuration: 3PST \/ TPST\u003c\/li\u003e\n\u003cli data-section-id=\"lfb4xa\" data-start=\"1283\" data-end=\"1326\"\u003eEnclosure Type: NEMA 3R (Outdoor Rated)\u003c\/li\u003e\n\u003cli data-section-id=\"13tpxhx\" data-start=\"1327\" data-end=\"1346\"\u003eMaterial: Steel\u003c\/li\u003e\n\u003cli data-section-id=\"rpxom\" data-start=\"1347\" data-end=\"1381\"\u003eInsulation Type: Non-Insulated\u003c\/li\u003e\n\u003cli data-section-id=\"1kv9bqt\" data-start=\"1382\" data-end=\"1408\"\u003eMounting Type: Surface\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1v2p98c\" data-start=\"1410\" data-end=\"1432\"\u003eElectrical Ratings\u003c\/h3\u003e\n\u003cul data-start=\"1434\" data-end=\"1623\"\u003e\n\u003cli data-section-id=\"17jx6g8\" data-start=\"1434\" data-end=\"1458\"\u003eCurrent Rating: 200A\u003c\/li\u003e\n\u003cli data-section-id=\"1t5slu\" data-start=\"1459\" data-end=\"1485\"\u003eVoltage Rating: 600VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1arf84i\" data-start=\"1486\" data-end=\"1513\"\u003eFrequency Rating: 60 Hz\u003c\/li\u003e\n\u003cli data-section-id=\"qp2tzz\" data-start=\"1514\" data-end=\"1541\"\u003eNumber of Poles: 3 Pole\u003c\/li\u003e\n\u003cli data-section-id=\"pvjmxy\" data-start=\"1542\" data-end=\"1560\"\u003ePhase: 3 Phase\u003c\/li\u003e\n\u003cli data-section-id=\"1y4szwx\" data-start=\"1561\" data-end=\"1583\"\u003eNumber of Wires: 4\u003c\/li\u003e\n\u003cli data-section-id=\"1eodzaa\" data-start=\"1584\" data-end=\"1623\"\u003eShort Circuit Current Rating: 200kA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"6vyzn4\" data-start=\"1625\" data-end=\"1649\"\u003eMotor \/ Load Ratings\u003c\/h3\u003e\n\u003cul data-start=\"1651\" data-end=\"1670\"\u003e\n\u003cli data-section-id=\"fyzrbm\" data-start=\"1651\" data-end=\"1660\"\u003e50 HP\u003c\/li\u003e\n\u003cli data-section-id=\"oat1ht\" data-start=\"1661\" data-end=\"1670\"\u003e60 HP\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"19zqy0x\" data-start=\"1672\" data-end=\"1684\"\u003eFeatures\u003c\/h3\u003e\n\u003cul data-start=\"1686\" data-end=\"2130\"\u003e\n\u003cli data-section-id=\"1tefo1d\" data-start=\"1686\" data-end=\"1722\"\u003eHeavy-duty fusible safety switch\u003c\/li\u003e\n\u003cli data-section-id=\"12n1kox\" data-start=\"1723\" data-end=\"1774\"\u003e3-pole, 4-wire configuration with solid neutral\u003c\/li\u003e\n\u003cli data-section-id=\"1gba3\" data-start=\"1775\" data-end=\"1818\"\u003eHigh 200kA short-circuit current rating\u003c\/li\u003e\n\u003cli data-section-id=\"1x5vhcf\" data-start=\"1819\" data-end=\"1876\"\u003eNEMA 3R rainproof enclosure for outdoor installations\u003c\/li\u003e\n\u003cli data-section-id=\"165cv8w\" data-start=\"1877\" data-end=\"1922\"\u003eReliable single-throw operating mechanism\u003c\/li\u003e\n\u003cli data-section-id=\"3tg37f\" data-start=\"1923\" data-end=\"1962\"\u003eMechanical lug terminal connections\u003c\/li\u003e\n\u003cli data-section-id=\"8i4nm1\" data-start=\"1963\" data-end=\"1989\"\u003eSurface-mounted design\u003c\/li\u003e\n\u003cli data-section-id=\"1gpwoh2\" data-start=\"1990\" data-end=\"2059\"\u003eSuitable for commercial and industrial power distribution systems\u003c\/li\u003e\n\u003cli data-section-id=\"14hhdml\" data-start=\"2060\" data-end=\"2130\"\u003eDesigned for equipment isolation and maintenance safety procedures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1uohfrv\" data-start=\"2132\" data-end=\"2148\"\u003eConstruction\u003c\/h3\u003e\n\u003cul data-start=\"2150\" data-end=\"2354\"\u003e\n\u003cli data-section-id=\"81c2gc\" data-start=\"2150\" data-end=\"2180\"\u003eHeavy-duty steel enclosure\u003c\/li\u003e\n\u003cli data-section-id=\"179pwjj\" data-start=\"2181\" data-end=\"2217\"\u003eNEMA 3R weather-resistant design\u003c\/li\u003e\n\u003cli data-section-id=\"q8ni23\" data-start=\"2218\" data-end=\"2251\"\u003eSurface-mounted configuration\u003c\/li\u003e\n\u003cli data-section-id=\"5y40k9\" data-start=\"2252\" data-end=\"2292\"\u003eIndustrial-grade switching mechanism\u003c\/li\u003e\n\u003cli data-section-id=\"wvzfwd\" data-start=\"2293\" data-end=\"2354\"\u003eBuilt for long-term durability and dependable performance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"16isa0t\" data-start=\"2356\" data-end=\"2383\"\u003ePhysical Specifications\u003c\/h3\u003e\n\u003cul data-start=\"2385\" data-end=\"2477\"\u003e\n\u003cli data-section-id=\"17yaosc\" data-start=\"2385\" data-end=\"2436\"\u003eDimensions: 29.9 in H × 15.94 in W × 12.33 in D\u003c\/li\u003e\n\u003cli data-section-id=\"oqset0\" data-start=\"2437\" data-end=\"2477\"\u003eOperating Temperature: -29°C to 85°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"nr5bwx\" data-start=\"2479\" data-end=\"2506\"\u003eStandards and Approvals\u003c\/h3\u003e\n\u003cul data-start=\"2508\" data-end=\"2551\"\u003e\n\u003cli data-section-id=\"11a7gqd\" data-start=\"2508\" data-end=\"2521\"\u003eUL Listed\u003c\/li\u003e\n\u003cli data-section-id=\"26q4wj\" data-start=\"2522\" data-end=\"2551\"\u003eSiemens Authentic Product\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"wggvqn\" data-start=\"2553\" data-end=\"2569\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"2571\" data-end=\"2951\"\u003e\n\u003cli data-section-id=\"1wjripk\" data-start=\"2571\" data-end=\"2620\"\u003eOutdoor commercial power distribution systems\u003c\/li\u003e\n\u003cli data-section-id=\"1kfy1m1\" data-start=\"2621\" data-end=\"2660\"\u003eIndustrial electrical installations\u003c\/li\u003e\n\u003cli data-section-id=\"1nf16e4\" data-start=\"2661\" data-end=\"2691\"\u003eService entrance equipment\u003c\/li\u003e\n\u003cli data-section-id=\"6ia6oy\" data-start=\"2692\" data-end=\"2739\"\u003eMotor disconnect and isolation applications\u003c\/li\u003e\n\u003cli data-section-id=\"b8qjje\" data-start=\"2740\" data-end=\"2785\"\u003eHVAC and mechanical equipment disconnects\u003c\/li\u003e\n\u003cli data-section-id=\"tic0f4\" data-start=\"2786\" data-end=\"2827\"\u003eUtility and infrastructure facilities\u003c\/li\u003e\n\u003cli data-section-id=\"1i9389u\" data-start=\"2828\" data-end=\"2890\"\u003eEquipment maintenance and lockout\/tagout (LOTO) procedures\u003c\/li\u003e\n\u003cli data-section-id=\"154up8s\" data-start=\"2891\" data-end=\"2951\"\u003eElectrical feeder and branch circuit disconnecting means\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens \/ ITE","offers":[{"title":"NEW","offer_id":48510413996281,"sku":"HF364NR","price":1132.65,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/HF263J-All-New-1_c0d1c7d3-2218-4b04-a918-c5b746910e0e.webp?v=1781117238","url":"https:\/\/mycircuitbreakers.com\/products\/siemens-hf364nr-safety-switch-vbii-series-200a-3-pole-600vac-heavy-duty-fusible-disconnect-with-solid-neutral-nema-3r-outdoor-enclosure","provider":"My Circuit Breakers","version":"1.0","type":"link"}