{"product_id":"siemens-hnf261-disconnect-switch-vbii-series-30a-2-pole-600vac-non-fused-type-1-enclosure","title":"Siemens HNF261 Disconnect Switch – VBII Series – 30A – 2 Pole – 600VAC – Non-Fused – Type 1 Enclosure","description":"\u003cp data-start=\"125\" data-end=\"475\"\u003eThe Siemens HNF261 is a VBII Series heavy-duty safety disconnect switch designed for reliable isolation and circuit control in industrial and commercial electrical systems. Rated at 30A and 600VAC, this 2-pole non-fused switch provides safe and efficient disconnection of electrical loads without integrated overcurrent protection.\u003c\/p\u003e\n\u003cp data-start=\"477\" data-end=\"728\"\u003eBuilt for indoor applications, the HNF261 comes in a Type 1 enclosure and is engineered for durability, safety, and dependable performance. It is suitable for use in power distribution systems where a simple and robust disconnect solution is required.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1yl5694\" data-start=\"730\" data-end=\"748\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-start=\"750\" data-end=\"991\"\u003e\n\u003cli data-section-id=\"4aesb7\" data-start=\"750\" data-end=\"774\"\u003eBrand: Siemens \/ ITE\u003c\/li\u003e\n\u003cli data-section-id=\"cyt0gk\" data-start=\"775\" data-end=\"798\"\u003ePart Number: HNF261\u003c\/li\u003e\n\u003cli data-section-id=\"1rq4mwx\" data-start=\"799\" data-end=\"822\"\u003eSeries: VBII Series\u003c\/li\u003e\n\u003cli data-section-id=\"ihwqgw\" data-start=\"823\" data-end=\"865\"\u003eType: HNF Heavy Duty Disconnect Switch\u003c\/li\u003e\n\u003cli data-section-id=\"1t9gf6v\" data-start=\"866\" data-end=\"916\"\u003eCategory: Safety Disconnect Switch \/ Non-Fused\u003c\/li\u003e\n\u003cli data-section-id=\"ri6age\" data-start=\"917\" data-end=\"952\"\u003eEnclosure Type: Type 1 (Indoor)\u003c\/li\u003e\n\u003cli data-section-id=\"lvwbhl\" data-start=\"953\" data-end=\"991\"\u003eConnection Type: Disconnect Switch\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1v2p98c\" data-start=\"993\" data-end=\"1015\"\u003eElectrical Ratings\u003c\/h3\u003e\n\u003cul data-start=\"1017\" data-end=\"1114\"\u003e\n\u003cli data-section-id=\"7spoqh\" data-start=\"1017\" data-end=\"1040\"\u003eCurrent Rating: 30A\u003c\/li\u003e\n\u003cli data-section-id=\"1t5slu\" data-start=\"1041\" data-end=\"1067\"\u003eVoltage Rating: 600VAC\u003c\/li\u003e\n\u003cli data-section-id=\"g1ar5q\" data-start=\"1068\" data-end=\"1095\"\u003eNumber of Poles: 2 Pole\u003c\/li\u003e\n\u003cli data-section-id=\"pvjmxy\" data-start=\"1096\" data-end=\"1114\"\u003ePhase: 3 Phase\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"15pi3o5\" data-start=\"1116\" data-end=\"1141\"\u003eInterrupting Capacity\u003c\/h3\u003e\n\u003cul data-start=\"1143\" data-end=\"1159\"\u003e\n\u003cli data-section-id=\"1x7fc5a\" data-start=\"1143\" data-end=\"1159\"\u003e100kA @ 480V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1uohfrv\" data-start=\"1161\" data-end=\"1177\"\u003eConstruction\u003c\/h3\u003e\n\u003cul data-start=\"1179\" data-end=\"1335\"\u003e\n\u003cli data-section-id=\"x6fnko\" data-start=\"1179\" data-end=\"1220\"\u003eHeavy-duty industrial-grade enclosure\u003c\/li\u003e\n\u003cli data-section-id=\"gp9mf8\" data-start=\"1221\" data-end=\"1260\"\u003eVBII series robust switch mechanism\u003c\/li\u003e\n\u003cli data-section-id=\"42whh9\" data-start=\"1261\" data-end=\"1301\"\u003eDesigned for reliable load isolation\u003c\/li\u003e\n\u003cli data-section-id=\"1wqk3q\" data-start=\"1302\" data-end=\"1335\"\u003eIndoor-rated Type 1 enclosure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1bgavjr\" data-start=\"1337\" data-end=\"1350\"\u003eFunctions\u003c\/h3\u003e\n\u003cul data-start=\"1352\" data-end=\"1466\"\u003e\n\u003cli data-section-id=\"c0d7yx\" data-start=\"1352\" data-end=\"1386\"\u003eNon-fused disconnect operation\u003c\/li\u003e\n\u003cli data-section-id=\"32l81f\" data-start=\"1387\" data-end=\"1418\"\u003eHeavy-duty safety switching\u003c\/li\u003e\n\u003cli data-section-id=\"kysy6f\" data-start=\"1419\" data-end=\"1466\"\u003eMechanical isolation of electrical circuits\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"nr5bwx\" data-start=\"1468\" data-end=\"1495\"\u003eStandards and Approvals\u003c\/h3\u003e\n\u003cul data-start=\"1497\" data-end=\"1513\"\u003e\n\u003cli data-section-id=\"3h4a0l\" data-start=\"1497\" data-end=\"1513\"\u003eCSA Approved\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"wggvqn\" data-start=\"1515\" data-end=\"1531\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"1533\" data-end=\"1732\"\u003e\n\u003cli data-section-id=\"ah30i2\" data-start=\"1533\" data-end=\"1562\"\u003eIndustrial control panels\u003c\/li\u003e\n\u003cli data-section-id=\"ov2tsh\" data-start=\"1563\" data-end=\"1609\"\u003eCommercial electrical distribution systems\u003c\/li\u003e\n\u003cli data-section-id=\"e2n1t7\" data-start=\"1610\" data-end=\"1656\"\u003eEquipment isolation and maintenance safety\u003c\/li\u003e\n\u003cli data-section-id=\"2tjv1d\" data-start=\"1657\" data-end=\"1694\"\u003eMotor and machinery disconnecting\u003c\/li\u003e\n\u003cli data-section-id=\"gu0565\" data-start=\"1695\" data-end=\"1732\"\u003eIndoor power distribution systems\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens \/ ITE","offers":[{"title":"NEW","offer_id":48513704591609,"sku":"HNF261","price":151.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/HNF261-All-New-1_4d05fda0-5aac-40f4-914d-e41e76014f04.webp?v=1781179712","url":"https:\/\/mycircuitbreakers.com\/products\/siemens-hnf261-disconnect-switch-vbii-series-30a-2-pole-600vac-non-fused-type-1-enclosure","provider":"My Circuit Breakers","version":"1.0","type":"link"}