{"product_id":"siemens-ite-ld63b600-600a-3-pole-mccb-bolt-on-600v","title":"Siemens \/ ITE LD63B600 600A 3 Pole MCCB – Bolt On – 600V","description":"\u003cp data-start=\"76\" data-end=\"722\"\u003eThe Siemens \/ ITE LD63B600 is a high-capacity molded case circuit breaker engineered for reliable protection and efficient power distribution in demanding industrial and commercial applications. With a 600A thermal magnetic interchangeable trip unit, it delivers precise protection against overloads and short circuit conditions. Built on the durable LD frame platform, this breaker ensures long operational life and stable performance under heavy electrical loads. Its bolt-on mounting system provides secure installation, while its multi-voltage compatibility allows flexible integration into various electrical systems.\u003c\/p\u003e\n\u003cp data-start=\"724\" data-end=\"752\"\u003e\u003cstrong data-start=\"724\" data-end=\"750\"\u003eProduct Specification:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"753\" data-end=\"1063\"\u003e\n\u003cli data-section-id=\"1n22tg8\" data-start=\"753\" data-end=\"784\"\u003eManufacturer: Siemens \/ ITE\u003c\/li\u003e\n\u003cli data-section-id=\"vys8ck\" data-start=\"785\" data-end=\"804\"\u003eModel: LD63B600\u003c\/li\u003e\n\u003cli data-section-id=\"6f1giq\" data-start=\"805\" data-end=\"829\"\u003eFrame Type: LD Frame\u003c\/li\u003e\n\u003cli data-section-id=\"6rlgrk\" data-start=\"830\" data-end=\"874\"\u003eType: Molded Case Circuit Breaker (MCCB)\u003c\/li\u003e\n\u003cli data-section-id=\"193xwen\" data-start=\"875\" data-end=\"901\"\u003eAmperage: 600A at 40°C\u003c\/li\u003e\n\u003cli data-section-id=\"kdtmuq\" data-start=\"902\" data-end=\"919\"\u003ePoles: 3 Pole\u003c\/li\u003e\n\u003cli data-section-id=\"o0hedk\" data-start=\"920\" data-end=\"948\"\u003eConnection Type: Bolt On\u003c\/li\u003e\n\u003cli data-section-id=\"11iboly\" data-start=\"949\" data-end=\"996\"\u003eTrip Unit: Thermal Magnetic Interchangeable\u003c\/li\u003e\n\u003cli data-section-id=\"1e1s6v\" data-start=\"997\" data-end=\"1042\"\u003eStandard Lug Type: Line and Load Standard\u003c\/li\u003e\n\u003cli data-section-id=\"1pruqjc\" data-start=\"1043\" data-end=\"1063\"\u003eWarranty: 1 Year\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1065\" data-end=\"1095\"\u003e\u003cstrong data-start=\"1065\" data-end=\"1093\"\u003eTechnical Specification:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1096\" data-end=\"1416\"\u003e\n\u003cli data-section-id=\"1mcgs16\" data-start=\"1096\" data-end=\"1138\"\u003eInterrupting Capacity: 65 kA @ 240V AC\u003c\/li\u003e\n\u003cli data-section-id=\"ys2xwl\" data-start=\"1139\" data-end=\"1181\"\u003eInterrupting Capacity: 35 kA @ 480V AC\u003c\/li\u003e\n\u003cli data-section-id=\"xcxf1q\" data-start=\"1182\" data-end=\"1224\"\u003eInterrupting Capacity: 25 kA @ 600V AC\u003c\/li\u003e\n\u003cli data-section-id=\"1dgz7de\" data-start=\"1225\" data-end=\"1258\"\u003eTrip Setting Range: 3000–6000\u003c\/li\u003e\n\u003cli data-section-id=\"1gofju0\" data-start=\"1259\" data-end=\"1282\"\u003eFrequency: 50\/60 Hz\u003c\/li\u003e\n\u003cli data-section-id=\"1sqv6nk\" data-start=\"1283\" data-end=\"1302\"\u003eFrame Style: LD\u003c\/li\u003e\n\u003cli data-section-id=\"5zwx1a\" data-start=\"1303\" data-end=\"1369\"\u003eOperating Mechanism: Fixed MCCB with interchangeable trip unit\u003c\/li\u003e\n\u003cli data-section-id=\"e9qnat\" data-start=\"1370\" data-end=\"1416\"\u003eTerminal Type: Line and Load End Terminals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1418\" data-end=\"1444\"\u003e\u003cstrong data-start=\"1418\" data-end=\"1442\"\u003eVoltage and Ratings:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1445\" data-end=\"1618\"\u003e\n\u003cli data-section-id=\"vdiwce\" data-start=\"1445\" data-end=\"1491\"\u003eRated Voltage: 240V AC \/ 480V AC \/ 600V AC\u003c\/li\u003e\n\u003cli data-section-id=\"1byddcq\" data-start=\"1492\" data-end=\"1520\"\u003eMaximum Voltage: 600V AC\u003c\/li\u003e\n\u003cli data-section-id=\"1ylq5ai\" data-start=\"1521\" data-end=\"1544\"\u003eRated Current: 600A\u003c\/li\u003e\n\u003cli data-section-id=\"1iricjn\" data-start=\"1545\" data-end=\"1618\"\u003eInterrupting Ratings: 65kA \/ 35kA \/ 25kA (depending on voltage level)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1620\" data-end=\"1639\"\u003e\u003cstrong data-start=\"1620\" data-end=\"1637\"\u003eProduct Data:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1640\" data-end=\"2120\"\u003e\n\u003cli data-section-id=\"c7nu5h\" data-start=\"1640\" data-end=\"1685\"\u003eProduct Type: Molded Case Circuit Breaker\u003c\/li\u003e\n\u003cli data-section-id=\"11a8uck\" data-start=\"1686\" data-end=\"1745\"\u003eApplication: Industrial and Commercial Power Protection\u003c\/li\u003e\n\u003cli data-section-id=\"156788j\" data-start=\"1746\" data-end=\"1772\"\u003eMounting Type: Bolt On\u003c\/li\u003e\n\u003cli data-section-id=\"1r4l45e\" data-start=\"1773\" data-end=\"1805\"\u003eConfiguration: 3 Pole System\u003c\/li\u003e\n\u003cli data-section-id=\"v20so7\" data-start=\"1806\" data-end=\"1907\"\u003eAccessories: Compatible with customizable accessories (installation support available on request)\u003c\/li\u003e\n\u003cli data-section-id=\"96w0yw\" data-start=\"1908\" data-end=\"1969\"\u003eConstruction: Heavy-duty industrial grade LD frame design\u003c\/li\u003e\n\u003cli data-section-id=\"kzoxzf\" data-start=\"1970\" data-end=\"2023\"\u003eTerminal Design: Standard Line and Load Terminals\u003c\/li\u003e\n\u003cli data-section-id=\"1kdl8fp\" data-start=\"2024\" data-end=\"2120\"\u003eWarranty Support: 1-year in-house warranty for certified reconditioned and new surplus units\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2122\" data-end=\"2460\"\u003e\u003cstrong data-start=\"2122\" data-end=\"2141\"\u003eImportant Note:\u003c\/strong\u003e\u003cbr data-start=\"2141\" data-end=\"2144\"\u003eThis circuit breaker must be installed by a qualified electrician according to applicable electrical codes and load requirements. Incorrect installation or improper selection may lead to equipment damage or safety hazards. Always verify voltage, current rating, and interrupting capacity before installation and use.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"New  Surplus","offer_id":48360302903545,"sku":"LD63B600-NS","price":1699.0,"currency_code":"USD","in_stock":true},{"title":"Certified Reconditioned","offer_id":48360302936313,"sku":"LD63B600-CR","price":1299.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/LD63B600.webp?v=1778062692","url":"https:\/\/mycircuitbreakers.com\/products\/siemens-ite-ld63b600-600a-3-pole-mccb-bolt-on-600v","provider":"My Circuit Breakers","version":"1.0","type":"link"}