{"product_id":"siemens-jxd22b250-circuit-breaker-sentron-series-250a-2-pole-240vac-thermal-magnetic-bolt-on","title":"Siemens JXD22B250 Circuit Breaker – Sentron Series – 250A – 2 Pole – 240VAC – Thermal Magnetic – Bolt-On","description":"\u003cp data-start=\"126\" data-end=\"515\"\u003eThe Siemens JXD22B250 is a Sentron Series molded case circuit breaker designed to provide dependable overload and short-circuit protection for commercial, industrial, and power distribution applications. Rated at 250A and 240VAC, this 2-pole breaker is engineered for single-phase electrical systems requiring reliable protection and high-performance fault interruption.\u003c\/p\u003e\n\u003cp data-start=\"517\" data-end=\"882\"\u003eFeaturing a thermal-magnetic trip unit with Long-Time and Instantaneous (LI) protection functions, the JXD22B250 delivers effective protection against overload conditions and short-circuit faults. With a 65kA interrupting capacity at 240VAC, it is capable of safely clearing high fault currents, helping protect electrical equipment and maintain system reliability.\u003c\/p\u003e\n\u003cp data-start=\"884\" data-end=\"1226\"\u003eBuilt on the JD frame platform and rated for operation in 40°C ambient conditions, this breaker utilizes a secure bolt-on mounting design and comes complete with a factory-installed non-interchangeable trip unit. Lugs are not included, allowing flexibility in selecting appropriate terminal connections for specific installation requirements.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1yl5694\" data-start=\"1228\" data-end=\"1246\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-start=\"1248\" data-end=\"1572\"\u003e\n\u003cli data-section-id=\"5vo7tw\" data-start=\"1248\" data-end=\"1264\"\u003eBrand: Siemens\u003c\/li\u003e\n\u003cli data-section-id=\"ywa08y\" data-start=\"1265\" data-end=\"1289\"\u003ePart Number: JXD22B250\u003c\/li\u003e\n\u003cli data-section-id=\"70zy16\" data-start=\"1290\" data-end=\"1314\"\u003eSeries: Sentron Series\u003c\/li\u003e\n\u003cli data-section-id=\"16ur9jz\" data-start=\"1315\" data-end=\"1354\"\u003eType: JXD Molded Case Circuit Breaker\u003c\/li\u003e\n\u003cli data-section-id=\"nbr2tf\" data-start=\"1355\" data-end=\"1377\"\u003eFrame Type: JD Frame\u003c\/li\u003e\n\u003cli data-section-id=\"1d6a76p\" data-start=\"1378\" data-end=\"1417\"\u003eCategory: Molded Case Circuit Breaker\u003c\/li\u003e\n\u003cli data-section-id=\"116koex\" data-start=\"1418\" data-end=\"1442\"\u003eMounting Type: Bolt-On\u003c\/li\u003e\n\u003cli data-section-id=\"14p4nbv\" data-start=\"1443\" data-end=\"1478\"\u003eProtection Type: Thermal Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"1i97zt2\" data-start=\"1479\" data-end=\"1511\"\u003eTrip Unit: Non-Interchangeable\u003c\/li\u003e\n\u003cli data-section-id=\"12ndhj1\" data-start=\"1512\" data-end=\"1534\"\u003eAmbient Rating: 40°C\u003c\/li\u003e\n\u003cli data-section-id=\"j32l6b\" data-start=\"1535\" data-end=\"1572\"\u003eSpecial Features: Lugs Not Included\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1v2p98c\" data-start=\"1574\" data-end=\"1596\"\u003eElectrical Ratings\u003c\/h3\u003e\n\u003cul data-start=\"1598\" data-end=\"1778\"\u003e\n\u003cli data-section-id=\"wit7fx\" data-start=\"1598\" data-end=\"1620\"\u003eCurrent Rating: 250A\u003c\/li\u003e\n\u003cli data-section-id=\"so37de\" data-start=\"1621\" data-end=\"1645\"\u003eVoltage Rating: 240VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1puk1a6\" data-start=\"1646\" data-end=\"1671\"\u003eNumber of Poles: 2 Pole\u003c\/li\u003e\n\u003cli data-section-id=\"4q3otg\" data-start=\"1672\" data-end=\"1688\"\u003ePhase: 1 Phase\u003c\/li\u003e\n\u003cli data-section-id=\"oft5zh\" data-start=\"1689\" data-end=\"1727\"\u003eInterrupting Capacity: 65kA @ 240VAC\u003c\/li\u003e\n\u003cli data-section-id=\"402970\" data-start=\"1728\" data-end=\"1778\"\u003eTrip Functions: LI – Long-Time and Instantaneous\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1uohfrv\" data-start=\"1780\" data-end=\"1796\"\u003eConstruction\u003c\/h3\u003e\n\u003cul data-start=\"1798\" data-end=\"2042\"\u003e\n\u003cli data-section-id=\"mipyan\" data-start=\"1798\" data-end=\"1835\"\u003eHeavy-duty molded case construction\u003c\/li\u003e\n\u003cli data-section-id=\"unkp5a\" data-start=\"1836\" data-end=\"1853\"\u003eJD frame design\u003c\/li\u003e\n\u003cli data-section-id=\"k3599n\" data-start=\"1854\" data-end=\"1886\"\u003eBolt-on mounting configuration\u003c\/li\u003e\n\u003cli data-section-id=\"1t6zvgz\" data-start=\"1887\" data-end=\"1920\"\u003eThermal-magnetic trip mechanism\u003c\/li\u003e\n\u003cli data-section-id=\"jj6bvp\" data-start=\"1921\" data-end=\"1970\"\u003eFactory-installed non-interchangeable trip unit\u003c\/li\u003e\n\u003cli data-section-id=\"qzdgfg\" data-start=\"1971\" data-end=\"2007\"\u003eField-selectable lug configuration\u003c\/li\u003e\n\u003cli data-section-id=\"1bd8b2w\" data-start=\"2008\" data-end=\"2042\"\u003eDurable industrial-grade housing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1bgavjr\" data-start=\"2044\" data-end=\"2057\"\u003eFunctions\u003c\/h3\u003e\n\u003cul data-start=\"2059\" data-end=\"2203\"\u003e\n\u003cli data-section-id=\"1fg39yc\" data-start=\"2059\" data-end=\"2080\"\u003eOverload protection\u003c\/li\u003e\n\u003cli data-section-id=\"2iygn4\" data-start=\"2081\" data-end=\"2107\"\u003eShort-circuit protection\u003c\/li\u003e\n\u003cli data-section-id=\"tf4f4b\" data-start=\"2108\" data-end=\"2136\"\u003eLong-time delay protection\u003c\/li\u003e\n\u003cli data-section-id=\"1mi5c9q\" data-start=\"2137\" data-end=\"2169\"\u003eInstantaneous fault protection\u003c\/li\u003e\n\u003cli data-section-id=\"160n1y9\" data-start=\"2170\" data-end=\"2203\"\u003eCircuit switching and isolation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"bpec4l\" data-start=\"2205\" data-end=\"2219\"\u003eDimensions\u003c\/h3\u003e\n\u003cul data-start=\"2221\" data-end=\"2266\"\u003e\n\u003cli data-section-id=\"1qewq9k\" data-start=\"2221\" data-end=\"2236\"\u003eWidth: 7.5 in\u003c\/li\u003e\n\u003cli data-section-id=\"1cq2yb1\" data-start=\"2237\" data-end=\"2252\"\u003eHeight: 11 in\u003c\/li\u003e\n\u003cli data-section-id=\"7f6jaj\" data-start=\"2253\" data-end=\"2266\"\u003eDepth: 4 in\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"w00lwu\" data-start=\"2268\" data-end=\"2281\"\u003eStandards\u003c\/h3\u003e\n\u003cul data-start=\"2283\" data-end=\"2294\"\u003e\n\u003cli data-section-id=\"jgz3lh\" data-start=\"2283\" data-end=\"2294\"\u003eUL Listed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"wggvqn\" data-start=\"2296\" data-end=\"2312\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"2314\" data-end=\"2571\"\u003e\n\u003cli data-section-id=\"wmvwwh\" data-start=\"2314\" data-end=\"2358\"\u003eCommercial electrical distribution systems\u003c\/li\u003e\n\u003cli data-section-id=\"3osc2v\" data-start=\"2359\" data-end=\"2400\"\u003eIndustrial power distribution equipment\u003c\/li\u003e\n\u003cli data-section-id=\"16mjukg\" data-start=\"2401\" data-end=\"2431\"\u003ePanelboards and switchboards\u003c\/li\u003e\n\u003cli data-section-id=\"fbt903\" data-start=\"2432\" data-end=\"2461\"\u003eEquipment feeder protection\u003c\/li\u003e\n\u003cli data-section-id=\"sd623m\" data-start=\"2462\" data-end=\"2494\"\u003eMotor and machinery protection\u003c\/li\u003e\n\u003cli data-section-id=\"154xwtc\" data-start=\"2495\" data-end=\"2529\"\u003eHigh fault-current installations\u003c\/li\u003e\n\u003cli data-section-id=\"kscm04\" data-start=\"2530\" data-end=\"2571\"\u003eSingle-phase power distribution systems\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens \/ ITE","offers":[{"title":"NEW","offer_id":48519376011513,"sku":"JXD22B250","price":1478.28,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/JXD22_e8cc8346-b0d4-4188-ab61-7876ce7672f3.webp?v=1781250405","url":"https:\/\/mycircuitbreakers.com\/products\/siemens-jxd22b250-circuit-breaker-sentron-series-250a-2-pole-240vac-thermal-magnetic-bolt-on","provider":"My Circuit Breakers","version":"1.0","type":"link"}