{"product_id":"siemens-jxd62b200-circuit-breaker-sentron-series-200a-2-pole-600vac-thermal-magnetic-feed-thru","title":"Siemens JXD62B200 Circuit Breaker – Sentron Series – 200A – 2 Pole – 600VAC – Thermal Magnetic – Feed-Thru","description":"\u003cp data-start=\"128\" data-end=\"513\"\u003eThe Siemens JXD62B200 is a Sentron Series molded case circuit breaker designed to provide dependable overload and short-circuit protection for commercial, industrial, and power distribution applications. Rated at 200A and 600VAC, this 2-pole breaker is engineered for single-phase electrical systems requiring reliable protection across higher-voltage installations.\u003c\/p\u003e\n\u003cp data-start=\"515\" data-end=\"896\"\u003eFeaturing a thermal-magnetic trip unit with Long-Time and Instantaneous (LI) protection functions, the JXD62B200 offers effective protection against sustained overloads and short-circuit faults. The breaker provides multiple interrupting ratings, including 100kA at 240VAC, 35kA at 480VAC, and 25kA at 600VAC, making it suitable for a wide range of power distribution applications.\u003c\/p\u003e\n\u003cp data-start=\"898\" data-end=\"1196\"\u003eBuilt on the Siemens JXD frame platform and calibrated for operation in 40°C ambient environments, this breaker utilizes a feed-thru connection design and comes complete with a factory-installed non-interchangeable trip unit as well as line- and load-side lug terminals for convenient installation.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1yl5694\" data-start=\"1198\" data-end=\"1216\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-start=\"1218\" data-end=\"1560\"\u003e\n\u003cli data-section-id=\"1v716in\" data-start=\"1218\" data-end=\"1243\"\u003eBrand: Siemens Breakers\u003c\/li\u003e\n\u003cli data-section-id=\"wb2s6b\" data-start=\"1244\" data-end=\"1268\"\u003ePart Number: JXD62B200\u003c\/li\u003e\n\u003cli data-section-id=\"70zy16\" data-start=\"1269\" data-end=\"1293\"\u003eSeries: Sentron Series\u003c\/li\u003e\n\u003cli data-section-id=\"16ur9jz\" data-start=\"1294\" data-end=\"1333\"\u003eType: JXD Molded Case Circuit Breaker\u003c\/li\u003e\n\u003cli data-section-id=\"1d6a76p\" data-start=\"1334\" data-end=\"1373\"\u003eCategory: Molded Case Circuit Breaker\u003c\/li\u003e\n\u003cli data-section-id=\"p3pxsf\" data-start=\"1374\" data-end=\"1402\"\u003eConnection Type: Feed-Thru\u003c\/li\u003e\n\u003cli data-section-id=\"14p4nbv\" data-start=\"1403\" data-end=\"1438\"\u003eProtection Type: Thermal Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"1i97zt2\" data-start=\"1439\" data-end=\"1471\"\u003eTrip Unit: Non-Interchangeable\u003c\/li\u003e\n\u003cli data-section-id=\"12ndhj1\" data-start=\"1472\" data-end=\"1494\"\u003eAmbient Rating: 40°C\u003c\/li\u003e\n\u003cli data-section-id=\"u1u24l\" data-start=\"1495\" data-end=\"1560\"\u003eTerminal Configuration: Line \u0026amp; Load Side Lug Terminals Included\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1v2p98c\" data-start=\"1562\" data-end=\"1584\"\u003eElectrical Ratings\u003c\/h3\u003e\n\u003cul data-start=\"1586\" data-end=\"1845\"\u003e\n\u003cli data-section-id=\"wit3ag\" data-start=\"1586\" data-end=\"1608\"\u003eCurrent Rating: 200A\u003c\/li\u003e\n\u003cli data-section-id=\"v6grde\" data-start=\"1609\" data-end=\"1633\"\u003eVoltage Rating: 600VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1puk1a6\" data-start=\"1634\" data-end=\"1659\"\u003eNumber of Poles: 2 Pole\u003c\/li\u003e\n\u003cli data-section-id=\"4q3otg\" data-start=\"1660\" data-end=\"1676\"\u003ePhase: 1 Phase\u003c\/li\u003e\n\u003cli data-section-id=\"ei2tvj\" data-start=\"1677\" data-end=\"1716\"\u003eInterrupting Capacity: 100kA @ 240VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1ei0vya\" data-start=\"1717\" data-end=\"1755\"\u003eInterrupting Capacity: 35kA @ 480VAC\u003c\/li\u003e\n\u003cli data-section-id=\"6jgphl\" data-start=\"1756\" data-end=\"1794\"\u003eInterrupting Capacity: 25kA @ 600VAC\u003c\/li\u003e\n\u003cli data-section-id=\"402970\" data-start=\"1795\" data-end=\"1845\"\u003eTrip Functions: LI – Long-Time and Instantaneous\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1uohfrv\" data-start=\"1847\" data-end=\"1863\"\u003eConstruction\u003c\/h3\u003e\n\u003cul data-start=\"1865\" data-end=\"2156\"\u003e\n\u003cli data-section-id=\"mipyan\" data-start=\"1865\" data-end=\"1902\"\u003eHeavy-duty molded case construction\u003c\/li\u003e\n\u003cli data-section-id=\"1984259\" data-start=\"1903\" data-end=\"1939\"\u003eFeed-thru connection configuration\u003c\/li\u003e\n\u003cli data-section-id=\"1t6zvgz\" data-start=\"1940\" data-end=\"1973\"\u003eThermal-magnetic trip mechanism\u003c\/li\u003e\n\u003cli data-section-id=\"jj6bvp\" data-start=\"1974\" data-end=\"2023\"\u003eFactory-installed non-interchangeable trip unit\u003c\/li\u003e\n\u003cli data-section-id=\"eub0di\" data-start=\"2024\" data-end=\"2068\"\u003eLine- and load-side lug terminals included\u003c\/li\u003e\n\u003cli data-section-id=\"132nc1j\" data-start=\"2069\" data-end=\"2102\"\u003eRugged industrial-grade housing\u003c\/li\u003e\n\u003cli data-section-id=\"1t9inat\" data-start=\"2103\" data-end=\"2156\"\u003eDesigned for high-voltage distribution applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1bgavjr\" data-start=\"2158\" data-end=\"2171\"\u003eFunctions\u003c\/h3\u003e\n\u003cul data-start=\"2173\" data-end=\"2317\"\u003e\n\u003cli data-section-id=\"1fg39yc\" data-start=\"2173\" data-end=\"2194\"\u003eOverload protection\u003c\/li\u003e\n\u003cli data-section-id=\"2iygn4\" data-start=\"2195\" data-end=\"2221\"\u003eShort-circuit protection\u003c\/li\u003e\n\u003cli data-section-id=\"tf4f4b\" data-start=\"2222\" data-end=\"2250\"\u003eLong-time delay protection\u003c\/li\u003e\n\u003cli data-section-id=\"1mi5c9q\" data-start=\"2251\" data-end=\"2283\"\u003eInstantaneous fault protection\u003c\/li\u003e\n\u003cli data-section-id=\"160n1y9\" data-start=\"2284\" data-end=\"2317\"\u003eCircuit switching and isolation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"bpec4l\" data-start=\"2319\" data-end=\"2333\"\u003eDimensions\u003c\/h3\u003e\n\u003cul data-start=\"2335\" data-end=\"2395\"\u003e\n\u003cli data-section-id=\"3mp50a\" data-start=\"2335\" data-end=\"2349\"\u003eHeight: 7 in\u003c\/li\u003e\n\u003cli data-section-id=\"2epv9p\" data-start=\"2350\" data-end=\"2363\"\u003eWidth: 9 in\u003c\/li\u003e\n\u003cli data-section-id=\"vt9we5\" data-start=\"2364\" data-end=\"2378\"\u003eDepth: 13 in\u003c\/li\u003e\n\u003cli data-section-id=\"17p49vz\" data-start=\"2379\" data-end=\"2395\"\u003eWeight: 16 lbs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"w00lwu\" data-start=\"2397\" data-end=\"2410\"\u003eStandards\u003c\/h3\u003e\n\u003cul data-start=\"2412\" data-end=\"2426\"\u003e\n\u003cli data-section-id=\"16shjxx\" data-start=\"2412\" data-end=\"2426\"\u003eCSA Approved\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"wggvqn\" data-start=\"2428\" data-end=\"2444\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"2446\" data-end=\"2709\"\u003e\n\u003cli data-section-id=\"wmvwwh\" data-start=\"2446\" data-end=\"2490\"\u003eCommercial electrical distribution systems\u003c\/li\u003e\n\u003cli data-section-id=\"3osc2v\" data-start=\"2491\" data-end=\"2532\"\u003eIndustrial power distribution equipment\u003c\/li\u003e\n\u003cli data-section-id=\"zbnhog\" data-start=\"2533\" data-end=\"2563\"\u003eSwitchboards and panelboards\u003c\/li\u003e\n\u003cli data-section-id=\"8o1696\" data-start=\"2564\" data-end=\"2591\"\u003eFeeder circuit protection\u003c\/li\u003e\n\u003cli data-section-id=\"k7zsmb\" data-start=\"2592\" data-end=\"2628\"\u003eEquipment and machinery protection\u003c\/li\u003e\n\u003cli data-section-id=\"1r0ss5y\" data-start=\"2629\" data-end=\"2662\"\u003eHigh-voltage electrical systems\u003c\/li\u003e\n\u003cli data-section-id=\"1pzdokb\" data-start=\"2663\" data-end=\"2709\"\u003eSingle-phase power distribution applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2711\" data-end=\"3008\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e \u003c\/p\u003e","brand":"Siemens \/ ITE","offers":[{"title":"NEW","offer_id":48523786191097,"sku":"JXD62B200","price":2002.79,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/JXD22_fcfb3404-b554-4f44-a222-8257048572b8.webp?v=1781269044","url":"https:\/\/mycircuitbreakers.com\/products\/siemens-jxd62b200-circuit-breaker-sentron-series-200a-2-pole-600vac-thermal-magnetic-feed-thru","provider":"My Circuit Breakers","version":"1.0","type":"link"}