{"product_id":"siemens-jxd62b250-circuit-breaker-sentron-series-250a-2-pole-600vac-thermal-magnetic-feed-thru","title":"Siemens JXD62B250 Circuit Breaker – Sentron Series – 250A – 2 Pole – 600VAC – Thermal Magnetic – Feed-Thru","description":"\u003cp data-start=\"128\" data-end=\"534\"\u003eThe Siemens JXD62B250 is a Sentron Series molded case circuit breaker designed to provide dependable overload and short-circuit protection for commercial, industrial, and power distribution applications. Rated at 250A and 600VAC, this 2-pole breaker is engineered for single-phase electrical systems requiring reliable protection and high-performance operation in demanding environments.\u003c\/p\u003e\n\u003cp data-start=\"536\" data-end=\"959\"\u003eEquipped with a thermal-magnetic trip unit featuring Long-Time and Instantaneous (LI) protection functions, the JXD62B250 delivers effective protection against sustained overload conditions and high-level fault currents. The breaker offers multiple interrupting ratings, including 100kA at 240VAC, 35kA at 480VAC, and 25kA at 600VAC, providing dependable fault-clearing performance across a variety of voltage applications.\u003c\/p\u003e\n\u003cp data-start=\"961\" data-end=\"1282\"\u003eBuilt on the Siemens JXD frame platform and calibrated for operation in 40°C ambient environments, this breaker features a feed-thru connection design and comes complete with a factory-installed non-interchangeable trip unit as well as line- and load-side lug terminals for simplified installation and secure connections.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1yl5694\" data-start=\"1284\" data-end=\"1302\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-start=\"1304\" data-end=\"1646\"\u003e\n\u003cli data-section-id=\"1v716in\" data-start=\"1304\" data-end=\"1329\"\u003eBrand: Siemens Breakers\u003c\/li\u003e\n\u003cli data-section-id=\"wb2s7a\" data-start=\"1330\" data-end=\"1354\"\u003ePart Number: JXD62B250\u003c\/li\u003e\n\u003cli data-section-id=\"70zy16\" data-start=\"1355\" data-end=\"1379\"\u003eSeries: Sentron Series\u003c\/li\u003e\n\u003cli data-section-id=\"16ur9jz\" data-start=\"1380\" data-end=\"1419\"\u003eType: JXD Molded Case Circuit Breaker\u003c\/li\u003e\n\u003cli data-section-id=\"1d6a76p\" data-start=\"1420\" data-end=\"1459\"\u003eCategory: Molded Case Circuit Breaker\u003c\/li\u003e\n\u003cli data-section-id=\"p3pxsf\" data-start=\"1460\" data-end=\"1488\"\u003eConnection Type: Feed-Thru\u003c\/li\u003e\n\u003cli data-section-id=\"14p4nbv\" data-start=\"1489\" data-end=\"1524\"\u003eProtection Type: Thermal Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"1i97zt2\" data-start=\"1525\" data-end=\"1557\"\u003eTrip Unit: Non-Interchangeable\u003c\/li\u003e\n\u003cli data-section-id=\"12ndhj1\" data-start=\"1558\" data-end=\"1580\"\u003eAmbient Rating: 40°C\u003c\/li\u003e\n\u003cli data-section-id=\"u1u24l\" data-start=\"1581\" data-end=\"1646\"\u003eTerminal Configuration: Line \u0026amp; Load Side Lug Terminals Included\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1v2p98c\" data-start=\"1648\" data-end=\"1670\"\u003eElectrical Ratings\u003c\/h3\u003e\n\u003cul data-start=\"1672\" data-end=\"1931\"\u003e\n\u003cli data-section-id=\"wit7fx\" data-start=\"1672\" data-end=\"1694\"\u003eCurrent Rating: 250A\u003c\/li\u003e\n\u003cli data-section-id=\"v6grde\" data-start=\"1695\" data-end=\"1719\"\u003eVoltage Rating: 600VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1puk1a6\" data-start=\"1720\" data-end=\"1745\"\u003eNumber of Poles: 2 Pole\u003c\/li\u003e\n\u003cli data-section-id=\"4q3otg\" data-start=\"1746\" data-end=\"1762\"\u003ePhase: 1 Phase\u003c\/li\u003e\n\u003cli data-section-id=\"ei2tvj\" data-start=\"1763\" data-end=\"1802\"\u003eInterrupting Capacity: 100kA @ 240VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1ei0vya\" data-start=\"1803\" data-end=\"1841\"\u003eInterrupting Capacity: 35kA @ 480VAC\u003c\/li\u003e\n\u003cli data-section-id=\"6jgphl\" data-start=\"1842\" data-end=\"1880\"\u003eInterrupting Capacity: 25kA @ 600VAC\u003c\/li\u003e\n\u003cli data-section-id=\"402970\" data-start=\"1881\" data-end=\"1931\"\u003eTrip Functions: LI – Long-Time and Instantaneous\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1uohfrv\" data-start=\"1933\" data-end=\"1949\"\u003eConstruction\u003c\/h3\u003e\n\u003cul data-start=\"1951\" data-end=\"2242\"\u003e\n\u003cli data-section-id=\"mipyan\" data-start=\"1951\" data-end=\"1988\"\u003eHeavy-duty molded case construction\u003c\/li\u003e\n\u003cli data-section-id=\"1984259\" data-start=\"1989\" data-end=\"2025\"\u003eFeed-thru connection configuration\u003c\/li\u003e\n\u003cli data-section-id=\"1t6zvgz\" data-start=\"2026\" data-end=\"2059\"\u003eThermal-magnetic trip mechanism\u003c\/li\u003e\n\u003cli data-section-id=\"jj6bvp\" data-start=\"2060\" data-end=\"2109\"\u003eFactory-installed non-interchangeable trip unit\u003c\/li\u003e\n\u003cli data-section-id=\"eub0di\" data-start=\"2110\" data-end=\"2154\"\u003eLine- and load-side lug terminals included\u003c\/li\u003e\n\u003cli data-section-id=\"132nc1j\" data-start=\"2155\" data-end=\"2188\"\u003eRugged industrial-grade housing\u003c\/li\u003e\n\u003cli data-section-id=\"1t9inat\" data-start=\"2189\" data-end=\"2242\"\u003eDesigned for high-voltage distribution applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1bgavjr\" data-start=\"2244\" data-end=\"2257\"\u003eFunctions\u003c\/h3\u003e\n\u003cul data-start=\"2259\" data-end=\"2403\"\u003e\n\u003cli data-section-id=\"1fg39yc\" data-start=\"2259\" data-end=\"2280\"\u003eOverload protection\u003c\/li\u003e\n\u003cli data-section-id=\"2iygn4\" data-start=\"2281\" data-end=\"2307\"\u003eShort-circuit protection\u003c\/li\u003e\n\u003cli data-section-id=\"tf4f4b\" data-start=\"2308\" data-end=\"2336\"\u003eLong-time delay protection\u003c\/li\u003e\n\u003cli data-section-id=\"1mi5c9q\" data-start=\"2337\" data-end=\"2369\"\u003eInstantaneous fault protection\u003c\/li\u003e\n\u003cli data-section-id=\"160n1y9\" data-start=\"2370\" data-end=\"2403\"\u003eCircuit switching and isolation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"bpec4l\" data-start=\"2405\" data-end=\"2419\"\u003eDimensions\u003c\/h3\u003e\n\u003cul data-start=\"2421\" data-end=\"2483\"\u003e\n\u003cli data-section-id=\"3mp50a\" data-start=\"2421\" data-end=\"2435\"\u003eHeight: 7 in\u003c\/li\u003e\n\u003cli data-section-id=\"2epv9p\" data-start=\"2436\" data-end=\"2449\"\u003eWidth: 9 in\u003c\/li\u003e\n\u003cli data-section-id=\"vt9we5\" data-start=\"2450\" data-end=\"2464\"\u003eDepth: 13 in\u003c\/li\u003e\n\u003cli data-section-id=\"1fmue6t\" data-start=\"2465\" data-end=\"2483\"\u003eWeight: 17.5 lbs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"w00lwu\" data-start=\"2485\" data-end=\"2498\"\u003eStandards\u003c\/h3\u003e\n\u003cul data-start=\"2500\" data-end=\"2514\"\u003e\n\u003cli data-section-id=\"16shjxx\" data-start=\"2500\" data-end=\"2514\"\u003eCSA Approved\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"wggvqn\" data-start=\"2516\" data-end=\"2532\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"2534\" data-end=\"2797\"\u003e\n\u003cli data-section-id=\"wmvwwh\" data-start=\"2534\" data-end=\"2578\"\u003eCommercial electrical distribution systems\u003c\/li\u003e\n\u003cli data-section-id=\"3osc2v\" data-start=\"2579\" data-end=\"2620\"\u003eIndustrial power distribution equipment\u003c\/li\u003e\n\u003cli data-section-id=\"zbnhog\" data-start=\"2621\" data-end=\"2651\"\u003eSwitchboards and panelboards\u003c\/li\u003e\n\u003cli data-section-id=\"8o1696\" data-start=\"2652\" data-end=\"2679\"\u003eFeeder circuit protection\u003c\/li\u003e\n\u003cli data-section-id=\"k7zsmb\" data-start=\"2680\" data-end=\"2716\"\u003eEquipment and machinery protection\u003c\/li\u003e\n\u003cli data-section-id=\"1r0ss5y\" data-start=\"2717\" data-end=\"2750\"\u003eHigh-voltage electrical systems\u003c\/li\u003e\n\u003cli data-section-id=\"1pzdokb\" data-start=\"2751\" data-end=\"2797\"\u003eSingle-phase power distribution applications\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens \/ ITE","offers":[{"title":"NEW","offer_id":48523808211193,"sku":"JXD62B250","price":2002.79,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/JXD22_71163354-d161-4eb9-ae40-d1ab2e79ed52.webp?v=1781269183","url":"https:\/\/mycircuitbreakers.com\/products\/siemens-jxd62b250-circuit-breaker-sentron-series-250a-2-pole-600vac-thermal-magnetic-feed-thru","provider":"My Circuit Breakers","version":"1.0","type":"link"}