{"product_id":"siemens-jxd62b350-circuit-breaker-sentron-series-350a-2-pole-600vac-thermal-magnetic-jd-frame","title":"Siemens JXD62B350 Circuit Breaker – Sentron Series – 350A – 2 Pole – 600VAC – Thermal Magnetic – JD Frame","description":"\u003cp data-start=\"127\" data-end=\"544\"\u003eThe Siemens JXD62B350 is a Sentron Series low-voltage molded case circuit breaker designed to provide dependable overload and short-circuit protection for commercial, industrial, and power distribution applications. Rated at 350A and 600VAC, this 2-pole breaker is engineered for single-phase electrical systems requiring high-capacity protection and reliable performance in demanding environments.\u003c\/p\u003e\n\u003cp data-start=\"546\" data-end=\"956\"\u003eEquipped with a thermal-magnetic trip unit featuring Long-Time and Instantaneous (LI) protection functions, the JXD62B350 delivers effective protection against overload conditions and high-level fault currents. Built on the Siemens JD frame platform, this standard 40°C breaker incorporates a non-interchangeable trip unit and standard breaking capacity to ensure consistent operation and equipment protection.\u003c\/p\u003e\n\u003cp data-start=\"958\" data-end=\"1307\"\u003eDesigned to meet UL 489 and IEC 60947-2 standards, the breaker is supplied without lugs installed, allowing flexibility in selecting compatible terminal connections based on application requirements. Its rugged construction makes it suitable for use in commercial facilities, industrial plants, and power distribution systems operating up to 600VAC.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1yl5694\" data-start=\"1309\" data-end=\"1327\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-start=\"1329\" data-end=\"1669\"\u003e\n\u003cli data-section-id=\"1v716in\" data-start=\"1329\" data-end=\"1354\"\u003eBrand: Siemens Breakers\u003c\/li\u003e\n\u003cli data-section-id=\"wb2ps7\" data-start=\"1355\" data-end=\"1379\"\u003ePart Number: JXD62B350\u003c\/li\u003e\n\u003cli data-section-id=\"70zy16\" data-start=\"1380\" data-end=\"1404\"\u003eSeries: Sentron Series\u003c\/li\u003e\n\u003cli data-section-id=\"1do12ey\" data-start=\"1405\" data-end=\"1449\"\u003eType: JD Frame Molded Case Circuit Breaker\u003c\/li\u003e\n\u003cli data-section-id=\"1d6a76p\" data-start=\"1450\" data-end=\"1489\"\u003eCategory: Molded Case Circuit Breaker\u003c\/li\u003e\n\u003cli data-section-id=\"41155u\" data-start=\"1490\" data-end=\"1516\"\u003eConnection Type: Bolt-On\u003c\/li\u003e\n\u003cli data-section-id=\"nbr2tf\" data-start=\"1517\" data-end=\"1539\"\u003eFrame Type: JD Frame\u003c\/li\u003e\n\u003cli data-section-id=\"14p4nbv\" data-start=\"1540\" data-end=\"1575\"\u003eProtection Type: Thermal Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"1i97zt2\" data-start=\"1576\" data-end=\"1608\"\u003eTrip Unit: Non-Interchangeable\u003c\/li\u003e\n\u003cli data-section-id=\"12ndhj1\" data-start=\"1609\" data-end=\"1631\"\u003eAmbient Rating: 40°C\u003c\/li\u003e\n\u003cli data-section-id=\"ypcv4v\" data-start=\"1632\" data-end=\"1669\"\u003eSpecial Features: No Lugs Installed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1v2p98c\" data-start=\"1671\" data-end=\"1693\"\u003eElectrical Ratings\u003c\/h3\u003e\n\u003cul data-start=\"1695\" data-end=\"1914\"\u003e\n\u003cli data-section-id=\"witz64\" data-start=\"1695\" data-end=\"1717\"\u003eCurrent Rating: 350A\u003c\/li\u003e\n\u003cli data-section-id=\"v6grde\" data-start=\"1718\" data-end=\"1742\"\u003eVoltage Rating: 600VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1puk1a6\" data-start=\"1743\" data-end=\"1768\"\u003eNumber of Poles: 2 Pole\u003c\/li\u003e\n\u003cli data-section-id=\"4q3otg\" data-start=\"1769\" data-end=\"1785\"\u003ePhase: 1 Phase\u003c\/li\u003e\n\u003cli data-section-id=\"1ei0vya\" data-start=\"1786\" data-end=\"1824\"\u003eInterrupting Capacity: 35kA @ 480VAC\u003c\/li\u003e\n\u003cli data-section-id=\"6jgphl\" data-start=\"1825\" data-end=\"1863\"\u003eInterrupting Capacity: 25kA @ 600VAC\u003c\/li\u003e\n\u003cli data-section-id=\"402970\" data-start=\"1864\" data-end=\"1914\"\u003eTrip Functions: LI – Long-Time and Instantaneous\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1uohfrv\" data-start=\"1916\" data-end=\"1932\"\u003eConstruction\u003c\/h3\u003e\n\u003cul data-start=\"1934\" data-end=\"2239\"\u003e\n\u003cli data-section-id=\"mipyan\" data-start=\"1934\" data-end=\"1971\"\u003eHeavy-duty molded case construction\u003c\/li\u003e\n\u003cli data-section-id=\"unkp5a\" data-start=\"1972\" data-end=\"1989\"\u003eJD frame design\u003c\/li\u003e\n\u003cli data-section-id=\"1t6zvgz\" data-start=\"1990\" data-end=\"2023\"\u003eThermal-magnetic trip mechanism\u003c\/li\u003e\n\u003cli data-section-id=\"1cq2qe4\" data-start=\"2024\" data-end=\"2055\"\u003eNon-interchangeable trip unit\u003c\/li\u003e\n\u003cli data-section-id=\"lemzp3\" data-start=\"2056\" data-end=\"2102\"\u003eStandard interrupting capacity configuration\u003c\/li\u003e\n\u003cli data-section-id=\"u50mzw\" data-start=\"2103\" data-end=\"2136\"\u003eSupplied without lugs installed\u003c\/li\u003e\n\u003cli data-section-id=\"1bd8b2w\" data-start=\"2137\" data-end=\"2171\"\u003eDurable industrial-grade housing\u003c\/li\u003e\n\u003cli data-section-id=\"am9g6c\" data-start=\"2172\" data-end=\"2239\"\u003eDesigned for commercial and industrial power distribution systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1bgavjr\" data-start=\"2241\" data-end=\"2254\"\u003eFunctions\u003c\/h3\u003e\n\u003cul data-start=\"2256\" data-end=\"2400\"\u003e\n\u003cli data-section-id=\"1fg39yc\" data-start=\"2256\" data-end=\"2277\"\u003eOverload protection\u003c\/li\u003e\n\u003cli data-section-id=\"2iygn4\" data-start=\"2278\" data-end=\"2304\"\u003eShort-circuit protection\u003c\/li\u003e\n\u003cli data-section-id=\"tf4f4b\" data-start=\"2305\" data-end=\"2333\"\u003eLong-time delay protection\u003c\/li\u003e\n\u003cli data-section-id=\"1mi5c9q\" data-start=\"2334\" data-end=\"2366\"\u003eInstantaneous fault protection\u003c\/li\u003e\n\u003cli data-section-id=\"160n1y9\" data-start=\"2367\" data-end=\"2400\"\u003eCircuit switching and isolation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"bpec4l\" data-start=\"2402\" data-end=\"2416\"\u003eDimensions\u003c\/h3\u003e\n\u003cul data-start=\"2418\" data-end=\"2482\"\u003e\n\u003cli data-section-id=\"1qewq9k\" data-start=\"2418\" data-end=\"2433\"\u003eWidth: 7.5 in\u003c\/li\u003e\n\u003cli data-section-id=\"1cq2yb1\" data-start=\"2434\" data-end=\"2449\"\u003eHeight: 11 in\u003c\/li\u003e\n\u003cli data-section-id=\"7f6jaj\" data-start=\"2450\" data-end=\"2463\"\u003eDepth: 4 in\u003c\/li\u003e\n\u003cli data-section-id=\"biz2hc\" data-start=\"2464\" data-end=\"2482\"\u003eWeight: 15.2 lbs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"w00lwu\" data-start=\"2484\" data-end=\"2497\"\u003eStandards\u003c\/h3\u003e\n\u003cul data-start=\"2499\" data-end=\"2536\"\u003e\n\u003cli data-section-id=\"ia41cz\" data-start=\"2499\" data-end=\"2507\"\u003eUL 489\u003c\/li\u003e\n\u003cli data-section-id=\"k3hhb7\" data-start=\"2508\" data-end=\"2521\"\u003eIEC 60947-2\u003c\/li\u003e\n\u003cli data-section-id=\"16shjxx\" data-start=\"2522\" data-end=\"2536\"\u003eCSA Approved\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"wggvqn\" data-start=\"2538\" data-end=\"2554\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"2556\" data-end=\"2820\"\u003e\n\u003cli data-section-id=\"wmvwwh\" data-start=\"2556\" data-end=\"2600\"\u003eCommercial electrical distribution systems\u003c\/li\u003e\n\u003cli data-section-id=\"3osc2v\" data-start=\"2601\" data-end=\"2642\"\u003eIndustrial power distribution equipment\u003c\/li\u003e\n\u003cli data-section-id=\"zbnhog\" data-start=\"2643\" data-end=\"2673\"\u003eSwitchboards and panelboards\u003c\/li\u003e\n\u003cli data-section-id=\"8o1696\" data-start=\"2674\" data-end=\"2701\"\u003eFeeder circuit protection\u003c\/li\u003e\n\u003cli data-section-id=\"k7zsmb\" data-start=\"2702\" data-end=\"2738\"\u003eEquipment and machinery protection\u003c\/li\u003e\n\u003cli data-section-id=\"kscm04\" data-start=\"2739\" data-end=\"2780\"\u003eSingle-phase power distribution systems\u003c\/li\u003e\n\u003cli data-section-id=\"1kblq4v\" data-start=\"2781\" data-end=\"2820\"\u003eHigh-voltage electrical installations\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens \/ ITE","offers":[{"title":"NEW","offer_id":48523855528185,"sku":"JXD62B350","price":2002.79,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/jxd62b350-New-1.webp?v=1781269476","url":"https:\/\/mycircuitbreakers.com\/products\/siemens-jxd62b350-circuit-breaker-sentron-series-350a-2-pole-600vac-thermal-magnetic-jd-frame","provider":"My Circuit Breakers","version":"1.0","type":"link"}