{"product_id":"siemens-lgb2b090b-circuit-breaker-vl-series-90a-2-pole-600vac-thermal-magnetic-bolt-on-panelboard-mount","title":"Siemens LGB2B090B Circuit Breaker – VL Series – 90A – 2 Pole – 600VAC – Thermal Magnetic – Bolt-On – Panelboard Mount","description":"\u003cp data-start=\"139\" data-end=\"537\"\u003eThe Siemens LGB2B090B is a VL Series molded case circuit breaker designed to deliver reliable overload and short-circuit protection for commercial, institutional, and industrial electrical distribution systems. Rated at 90A and 600VAC, this 2-pole breaker is engineered for single-phase applications requiring compact size, high interrupting capacity, and dependable performance.\u003c\/p\u003e\n\u003cp data-start=\"539\" data-end=\"899\"\u003eEquipped with a thermal-magnetic trip unit featuring Long-Time and Instantaneous (LI) protection functions, the LGB2B090B provides effective protection against sustained overload conditions and high fault currents. Its high interrupting capability of 100kA at 240VAC makes it suitable for demanding electrical systems where strong fault protection is required.\u003c\/p\u003e\n\u003cp data-start=\"901\" data-end=\"1208\"\u003eBuilt on Siemens’ VL Series (LGB frame), this breaker is designed for panelboard mounting and supports reverse-feed applications for added installation flexibility. It includes load-side lug terminals and is engineered for secure connections and long-term reliability in high-performance electrical systems.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1yl5694\" data-start=\"1210\" data-end=\"1228\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-start=\"1230\" data-end=\"1622\"\u003e\n\u003cli data-section-id=\"4aesb7\" data-start=\"1230\" data-end=\"1254\"\u003eBrand: Siemens \/ ITE\u003c\/li\u003e\n\u003cli data-section-id=\"kbrk2r\" data-start=\"1255\" data-end=\"1281\"\u003ePart Number: LGB2B090B\u003c\/li\u003e\n\u003cli data-section-id=\"1puc5v3\" data-start=\"1282\" data-end=\"1303\"\u003eSeries: VL Series\u003c\/li\u003e\n\u003cli data-section-id=\"1xrl1b4\" data-start=\"1304\" data-end=\"1345\"\u003eType: LGB Molded Case Circuit Breaker\u003c\/li\u003e\n\u003cli data-section-id=\"1n7n40y\" data-start=\"1346\" data-end=\"1375\"\u003eFrame Type: G Frame (LGB)\u003c\/li\u003e\n\u003cli data-section-id=\"1ssq2xt\" data-start=\"1376\" data-end=\"1417\"\u003eCategory: Molded Case Circuit Breaker\u003c\/li\u003e\n\u003cli data-section-id=\"49b8gp\" data-start=\"1418\" data-end=\"1444\"\u003eMounting Type: Bolt-On\u003c\/li\u003e\n\u003cli data-section-id=\"1d3tnsg\" data-start=\"1445\" data-end=\"1487\"\u003eInstallation Type: Panelboard Mounting\u003c\/li\u003e\n\u003cli data-section-id=\"1vwficb\" data-start=\"1488\" data-end=\"1525\"\u003eProtection Type: Thermal Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"p0ct1o\" data-start=\"1526\" data-end=\"1578\"\u003eTrip Functions: LI – Long-Time and Instantaneous\u003c\/li\u003e\n\u003cli data-section-id=\"zhqou8\" data-start=\"1579\" data-end=\"1622\"\u003eSpecial Features: Reverse Feed Suitable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1v2p98c\" data-start=\"1624\" data-end=\"1646\"\u003eElectrical Ratings\u003c\/h3\u003e\n\u003cul data-start=\"1648\" data-end=\"1936\"\u003e\n\u003cli data-section-id=\"7oh6cz\" data-start=\"1648\" data-end=\"1671\"\u003eCurrent Rating: 90A\u003c\/li\u003e\n\u003cli data-section-id=\"1t5slu\" data-start=\"1672\" data-end=\"1698\"\u003eVoltage Rating: 600VAC\u003c\/li\u003e\n\u003cli data-section-id=\"g1ar5q\" data-start=\"1699\" data-end=\"1726\"\u003eNumber of Poles: 2 Pole\u003c\/li\u003e\n\u003cli data-section-id=\"vdhrok\" data-start=\"1727\" data-end=\"1745\"\u003ePhase: 1 Phase\u003c\/li\u003e\n\u003cli data-section-id=\"o0ll1b\" data-start=\"1746\" data-end=\"1787\"\u003eInterrupting Capacity: 100kA @ 240VAC\u003c\/li\u003e\n\u003cli data-section-id=\"10e2s6r\" data-start=\"1788\" data-end=\"1875\"\u003eAdditional System Ratings: High interrupting capacity design for panelboard systems\u003c\/li\u003e\n\u003cli data-section-id=\"1bgrh65\" data-start=\"1876\" data-end=\"1936\"\u003eTerminal Configuration: Load Side Lug Terminals Included\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1uohfrv\" data-start=\"1938\" data-end=\"1954\"\u003eConstruction\u003c\/h3\u003e\n\u003cul data-start=\"1956\" data-end=\"2246\"\u003e\n\u003cli data-section-id=\"gjs8hx\" data-start=\"1956\" data-end=\"1986\"\u003eCompact molded case design\u003c\/li\u003e\n\u003cli data-section-id=\"19qc3tw\" data-start=\"1987\" data-end=\"2021\"\u003eVL Series G-frame construction\u003c\/li\u003e\n\u003cli data-section-id=\"10ro68j\" data-start=\"2022\" data-end=\"2057\"\u003eThermal-magnetic trip mechanism\u003c\/li\u003e\n\u003cli data-section-id=\"1wogizv\" data-start=\"2058\" data-end=\"2092\"\u003eBolt-on mounting configuration\u003c\/li\u003e\n\u003cli data-section-id=\"1hump7d\" data-start=\"2093\" data-end=\"2131\"\u003ePanelboard installation compatible\u003c\/li\u003e\n\u003cli data-section-id=\"lf9xqf\" data-start=\"2132\" data-end=\"2172\"\u003eHigh interrupting capacity structure\u003c\/li\u003e\n\u003cli data-section-id=\"1labyge\" data-start=\"2173\" data-end=\"2209\"\u003eLoad-side lug terminals included\u003c\/li\u003e\n\u003cli data-section-id=\"esjd3s\" data-start=\"2210\" data-end=\"2246\"\u003eDurable industrial-grade housing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1bgavjr\" data-start=\"2248\" data-end=\"2261\"\u003eFunctions\u003c\/h3\u003e\n\u003cul data-start=\"2263\" data-end=\"2417\"\u003e\n\u003cli data-section-id=\"1hecu90\" data-start=\"2263\" data-end=\"2286\"\u003eOverload protection\u003c\/li\u003e\n\u003cli data-section-id=\"1ga7cu8\" data-start=\"2287\" data-end=\"2315\"\u003eShort-circuit protection\u003c\/li\u003e\n\u003cli data-section-id=\"3iwljf\" data-start=\"2316\" data-end=\"2346\"\u003eLong-time delay protection\u003c\/li\u003e\n\u003cli data-section-id=\"1van10e\" data-start=\"2347\" data-end=\"2381\"\u003eInstantaneous fault protection\u003c\/li\u003e\n\u003cli data-section-id=\"dgupsx\" data-start=\"2382\" data-end=\"2417\"\u003eCircuit switching and isolation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"bpec4l\" data-start=\"2419\" data-end=\"2433\"\u003eDimensions\u003c\/h3\u003e\n\u003cul data-start=\"2435\" data-end=\"2508\"\u003e\n\u003cli data-section-id=\"18c2g0u\" data-start=\"2435\" data-end=\"2451\"\u003eHeight: 3 in\u003c\/li\u003e\n\u003cli data-section-id=\"12p9ul7\" data-start=\"2452\" data-end=\"2469\"\u003eWidth: 5.4 in\u003c\/li\u003e\n\u003cli data-section-id=\"1u3vj7f\" data-start=\"2470\" data-end=\"2487\"\u003eDepth: 2.8 in\u003c\/li\u003e\n\u003cli data-section-id=\"f1nwnu\" data-start=\"2488\" data-end=\"2508\"\u003eWeight: 1.85 lbs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"w00lwu\" data-start=\"2510\" data-end=\"2523\"\u003eStandards\u003c\/h3\u003e\n\u003cul data-start=\"2525\" data-end=\"2555\"\u003e\n\u003cli data-section-id=\"11a7gqd\" data-start=\"2525\" data-end=\"2538\"\u003eUL Listed\u003c\/li\u003e\n\u003cli data-section-id=\"3h4a0l\" data-start=\"2539\" data-end=\"2555\"\u003eCSA Approved\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"wggvqn\" data-start=\"2557\" data-end=\"2573\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"2575\" data-end=\"2834\"\u003e\n\u003cli data-section-id=\"ov2tsh\" data-start=\"2575\" data-end=\"2621\"\u003eCommercial electrical distribution systems\u003c\/li\u003e\n\u003cli data-section-id=\"1w6ailz\" data-start=\"2622\" data-end=\"2648\"\u003eIndustrial panelboards\u003c\/li\u003e\n\u003cli data-section-id=\"1jabemj\" data-start=\"2649\" data-end=\"2678\"\u003eBranch circuit protection\u003c\/li\u003e\n\u003cli data-section-id=\"1d0v23k\" data-start=\"2679\" data-end=\"2715\"\u003eHigh fault-current installations\u003c\/li\u003e\n\u003cli data-section-id=\"1e1o64u\" data-start=\"2716\" data-end=\"2752\"\u003eInstitutional electrical systems\u003c\/li\u003e\n\u003cli data-section-id=\"utmjxb\" data-start=\"2753\" data-end=\"2797\"\u003eLighting and power distribution circuits\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens \/ ITE","offers":[{"title":"NEW","offer_id":48524004327673,"sku":"LGB2B090B","price":396.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/LGB2B020B-new-1_4d59d114-7d38-46dc-a23d-93292d508490.jpg?v=1781270496","url":"https:\/\/mycircuitbreakers.com\/products\/siemens-lgb2b090b-circuit-breaker-vl-series-90a-2-pole-600vac-thermal-magnetic-bolt-on-panelboard-mount","provider":"My Circuit Breakers","version":"1.0","type":"link"}