{"product_id":"siemens-lxd62b500-circuit-breaker-sentron-series-500a-2-pole-600vac-thermal-magnetic-bolt-on-ld-frame","title":"Siemens LXD62B500 Circuit Breaker – Sentron Series – 500A – 2 Pole – 600VAC – Thermal Magnetic – Bolt-On – LD Frame","description":"\u003cp data-start=\"137\" data-end=\"546\"\u003eThe Siemens LXD62B500 is a Sentron Series low-voltage molded case circuit breaker engineered for high-capacity overload and short-circuit protection in commercial, industrial, and power distribution systems. Rated at 500A and 600VAC, this 2-pole breaker is designed for heavy-duty applications requiring reliable performance and robust fault protection in demanding electrical environments.\u003c\/p\u003e\n\u003cp data-start=\"548\" data-end=\"954\"\u003eEquipped with a thermal-magnetic trip unit featuring Long-Time and Instantaneous (LI) protection functions, the LXD62B500 provides effective protection against sustained overload conditions and high-level short-circuit faults. Built on Siemens’ LD frame platform, this breaker is calibrated for standard 40°C operation and incorporates a non-interchangeable trip unit for consistent protection performance.\u003c\/p\u003e\n\u003cp data-start=\"956\" data-end=\"1258\"\u003eThe breaker meets UL 489 and IEC 60947-2 standards and is supplied without lugs installed, allowing flexibility in selecting appropriate terminal accessories for specific installation requirements. Its rugged molded case construction ensures durability and long service life in industrial applications.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1yl5694\" data-start=\"1260\" data-end=\"1278\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-start=\"1280\" data-end=\"1688\"\u003e\n\u003cli data-section-id=\"dwpo3j\" data-start=\"1280\" data-end=\"1307\"\u003eBrand: Siemens Breakers\u003c\/li\u003e\n\u003cli data-section-id=\"vcjm3m\" data-start=\"1308\" data-end=\"1334\"\u003ePart Number: LXD62B500\u003c\/li\u003e\n\u003cli data-section-id=\"1gwamq2\" data-start=\"1335\" data-end=\"1361\"\u003eSeries: Sentron Series\u003c\/li\u003e\n\u003cli data-section-id=\"12rdjx5\" data-start=\"1362\" data-end=\"1403\"\u003eType: LXD Molded Case Circuit Breaker\u003c\/li\u003e\n\u003cli data-section-id=\"1ksr3gl\" data-start=\"1404\" data-end=\"1428\"\u003eFrame Type: LD Frame\u003c\/li\u003e\n\u003cli data-section-id=\"1ssq2xt\" data-start=\"1429\" data-end=\"1470\"\u003eCategory: Molded Case Circuit Breaker\u003c\/li\u003e\n\u003cli data-section-id=\"49b8gp\" data-start=\"1471\" data-end=\"1497\"\u003eMounting Type: Bolt-On\u003c\/li\u003e\n\u003cli data-section-id=\"1vwficb\" data-start=\"1498\" data-end=\"1535\"\u003eProtection Type: Thermal Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"p0ct1o\" data-start=\"1536\" data-end=\"1588\"\u003eTrip Functions: LI – Long-Time and Instantaneous\u003c\/li\u003e\n\u003cli data-section-id=\"1ma8l8m\" data-start=\"1589\" data-end=\"1623\"\u003eTrip Unit: Non-Interchangeable\u003c\/li\u003e\n\u003cli data-section-id=\"12sas1p\" data-start=\"1624\" data-end=\"1648\"\u003eAmbient Rating: 40°C\u003c\/li\u003e\n\u003cli data-section-id=\"4m8mcf\" data-start=\"1649\" data-end=\"1688\"\u003eSpecial Features: No Lugs Installed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1v2p98c\" data-start=\"1690\" data-end=\"1712\"\u003eElectrical Ratings\u003c\/h3\u003e\n\u003cul data-start=\"1714\" data-end=\"1965\"\u003e\n\u003cli data-section-id=\"1c1j1u7\" data-start=\"1714\" data-end=\"1738\"\u003eCurrent Rating: 500A\u003c\/li\u003e\n\u003cli data-section-id=\"1t5slu\" data-start=\"1739\" data-end=\"1765\"\u003eVoltage Rating: 600VAC\u003c\/li\u003e\n\u003cli data-section-id=\"g1ar5q\" data-start=\"1766\" data-end=\"1793\"\u003eNumber of Poles: 2 Pole\u003c\/li\u003e\n\u003cli data-section-id=\"168d7xz\" data-start=\"1794\" data-end=\"1827\"\u003ePhase: 3 Phase (as specified)\u003c\/li\u003e\n\u003cli data-section-id=\"hbo3sy\" data-start=\"1828\" data-end=\"1868\"\u003eInterrupting Capacity: 35kA @ 480VAC\u003c\/li\u003e\n\u003cli data-section-id=\"jp5iix\" data-start=\"1869\" data-end=\"1909\"\u003eInterrupting Capacity: 25kA @ 600VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1spb3m3\" data-start=\"1910\" data-end=\"1965\"\u003eSystem Rating: 100kA @ 480VAC (design-level rating)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1uohfrv\" data-start=\"1967\" data-end=\"1983\"\u003eConstruction\u003c\/h3\u003e\n\u003cul data-start=\"1985\" data-end=\"2261\"\u003e\n\u003cli data-section-id=\"in7hi7\" data-start=\"1985\" data-end=\"2024\"\u003eHeavy-duty molded case construction\u003c\/li\u003e\n\u003cli data-section-id=\"urdzns\" data-start=\"2025\" data-end=\"2044\"\u003eLD frame design\u003c\/li\u003e\n\u003cli data-section-id=\"10ro68j\" data-start=\"2045\" data-end=\"2080\"\u003eThermal-magnetic trip mechanism\u003c\/li\u003e\n\u003cli data-section-id=\"1wogizv\" data-start=\"2081\" data-end=\"2115\"\u003eBolt-on mounting configuration\u003c\/li\u003e\n\u003cli data-section-id=\"pje3g\" data-start=\"2116\" data-end=\"2149\"\u003eNon-interchangeable trip unit\u003c\/li\u003e\n\u003cli data-section-id=\"1ss1f79\" data-start=\"2150\" data-end=\"2188\"\u003eStandard 40°C calibrated operation\u003c\/li\u003e\n\u003cli data-section-id=\"5iaa98\" data-start=\"2189\" data-end=\"2224\"\u003eSupplied without lugs installed\u003c\/li\u003e\n\u003cli data-section-id=\"1rjce7s\" data-start=\"2225\" data-end=\"2261\"\u003eIndustrial-grade durable housing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1bgavjr\" data-start=\"2263\" data-end=\"2276\"\u003eFunctions\u003c\/h3\u003e\n\u003cul data-start=\"2278\" data-end=\"2432\"\u003e\n\u003cli data-section-id=\"1hecu90\" data-start=\"2278\" data-end=\"2301\"\u003eOverload protection\u003c\/li\u003e\n\u003cli data-section-id=\"1ga7cu8\" data-start=\"2302\" data-end=\"2330\"\u003eShort-circuit protection\u003c\/li\u003e\n\u003cli data-section-id=\"3iwljf\" data-start=\"2331\" data-end=\"2361\"\u003eLong-time delay protection\u003c\/li\u003e\n\u003cli data-section-id=\"1van10e\" data-start=\"2362\" data-end=\"2396\"\u003eInstantaneous fault protection\u003c\/li\u003e\n\u003cli data-section-id=\"dgupsx\" data-start=\"2397\" data-end=\"2432\"\u003eCircuit switching and isolation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"bpec4l\" data-start=\"2434\" data-end=\"2448\"\u003eDimensions\u003c\/h3\u003e\n\u003cul data-start=\"2450\" data-end=\"2524\"\u003e\n\u003cli data-section-id=\"1rge1vc\" data-start=\"2450\" data-end=\"2467\"\u003eWidth: 7.5 in\u003c\/li\u003e\n\u003cli data-section-id=\"w6svh\" data-start=\"2468\" data-end=\"2485\"\u003eHeight: 11 in\u003c\/li\u003e\n\u003cli data-section-id=\"1jqzf3f\" data-start=\"2486\" data-end=\"2501\"\u003eDepth: 4 in\u003c\/li\u003e\n\u003cli data-section-id=\"vg90ep\" data-start=\"2502\" data-end=\"2524\"\u003eWeight: 15.201 lbs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"w00lwu\" data-start=\"2526\" data-end=\"2539\"\u003eStandards\u003c\/h3\u003e\n\u003cul data-start=\"2541\" data-end=\"2584\"\u003e\n\u003cli data-section-id=\"j8lt5v\" data-start=\"2541\" data-end=\"2551\"\u003eUL 489\u003c\/li\u003e\n\u003cli data-section-id=\"7x3s2r\" data-start=\"2552\" data-end=\"2567\"\u003eIEC 60947-2\u003c\/li\u003e\n\u003cli data-section-id=\"3h4a0l\" data-start=\"2568\" data-end=\"2584\"\u003eCSA Approved\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"wggvqn\" data-start=\"2586\" data-end=\"2602\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"2604\" data-end=\"2852\"\u003e\n\u003cli data-section-id=\"1g63lej\" data-start=\"2604\" data-end=\"2645\"\u003eIndustrial power distribution systems\u003c\/li\u003e\n\u003cli data-section-id=\"z3kxs6\" data-start=\"2646\" data-end=\"2684\"\u003eCommercial electrical switchboards\u003c\/li\u003e\n\u003cli data-section-id=\"1bj3kx7\" data-start=\"2685\" data-end=\"2717\"\u003eHeavy-duty feeder protection\u003c\/li\u003e\n\u003cli data-section-id=\"oicrpo\" data-start=\"2718\" data-end=\"2746\"\u003eManufacturing facilities\u003c\/li\u003e\n\u003cli data-section-id=\"1vuh140\" data-start=\"2747\" data-end=\"2783\"\u003eHigh-capacity electrical systems\u003c\/li\u003e\n\u003cli data-section-id=\"28vr8j\" data-start=\"2784\" data-end=\"2822\"\u003eEquipment and machinery protection\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens \/ ITE","offers":[{"title":"NEW","offer_id":48524117442809,"sku":"LXD62B500","price":1891.03,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/JXD23S400A-All-New-1_4141a099-766d-456d-b37e-096f646d588f.webp?v=1781271237","url":"https:\/\/mycircuitbreakers.com\/products\/siemens-lxd62b500-circuit-breaker-sentron-series-500a-2-pole-600vac-thermal-magnetic-bolt-on-ld-frame","provider":"My Circuit Breakers","version":"1.0","type":"link"}