{"product_id":"siemens-neg3b015l-circuit-breaker-vl-series-eg-frame-15a-3-pole-600vac-feed-thru-thermal-magnetic","title":"Siemens NEG3B015L Circuit Breaker – VL Series – EG Frame – 15A – 3 Pole – 600VAC – Feed-Thru – Thermal Magnetic","description":"\u003cp data-start=\"133\" data-end=\"500\"\u003eThe Siemens NEG3B015L is a VL Series molded case circuit breaker designed for reliable protection in low-voltage industrial and commercial power distribution systems. Rated at 15A and 600VAC, this 3-pole breaker is built on the EG frame platform and is suitable for three-phase applications requiring compact, high-interrupting-capacity protection.\u003c\/p\u003e\n\u003cp data-start=\"502\" data-end=\"836\"\u003eEquipped with a thermal-magnetic trip unit, the NEG3B015L provides Long-Time and Instantaneous (LI) protection, ensuring dependable response to overload and short-circuit conditions. Its feed-thru construction and included line and load side lugs make it suitable for straightforward installation in panelboard and switchgear systems.\u003c\/p\u003e\n\u003cp data-start=\"838\" data-end=\"958\"\u003eThis breaker is UL listed and engineered for durability and consistent performance in demanding electrical environments.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1yl5694\" data-start=\"960\" data-end=\"978\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-start=\"980\" data-end=\"1329\"\u003e\n\u003cli data-section-id=\"dwpo3j\" data-start=\"980\" data-end=\"1007\"\u003eBrand: Siemens Breakers\u003c\/li\u003e\n\u003cli data-section-id=\"tec9wk\" data-start=\"1008\" data-end=\"1034\"\u003ePart Number: NEG3B015L\u003c\/li\u003e\n\u003cli data-section-id=\"1puc5v3\" data-start=\"1035\" data-end=\"1056\"\u003eSeries: VL Series\u003c\/li\u003e\n\u003cli data-section-id=\"m6jynj\" data-start=\"1057\" data-end=\"1081\"\u003eFrame Type: EG Frame\u003c\/li\u003e\n\u003cli data-section-id=\"1ssq2xt\" data-start=\"1082\" data-end=\"1123\"\u003eCategory: Molded Case Circuit Breaker\u003c\/li\u003e\n\u003cli data-section-id=\"m8fqk4\" data-start=\"1124\" data-end=\"1152\"\u003eMounting Type: Feed-Thru\u003c\/li\u003e\n\u003cli data-section-id=\"1ivewjk\" data-start=\"1153\" data-end=\"1178\"\u003eConfiguration: 3 Pole\u003c\/li\u003e\n\u003cli data-section-id=\"1vwficb\" data-start=\"1179\" data-end=\"1216\"\u003eProtection Type: Thermal Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"p0ct1o\" data-start=\"1217\" data-end=\"1269\"\u003eTrip Functions: LI – Long-Time and Instantaneous\u003c\/li\u003e\n\u003cli data-section-id=\"esact1\" data-start=\"1270\" data-end=\"1329\"\u003eAmbient Rating: 40°C (standard EG frame design context)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1v2p98c\" data-start=\"1331\" data-end=\"1353\"\u003eElectrical Ratings\u003c\/h3\u003e\n\u003cul data-start=\"1355\" data-end=\"1553\"\u003e\n\u003cli data-section-id=\"7u5c7y\" data-start=\"1355\" data-end=\"1378\"\u003eCurrent Rating: 15A\u003c\/li\u003e\n\u003cli data-section-id=\"18d5o8a\" data-start=\"1379\" data-end=\"1434\"\u003eVoltage Rating: 600VAC (600Y\/347VAC system capable)\u003c\/li\u003e\n\u003cli data-section-id=\"qp2tzz\" data-start=\"1435\" data-end=\"1462\"\u003eNumber of Poles: 3 Pole\u003c\/li\u003e\n\u003cli data-section-id=\"pvjmxy\" data-start=\"1463\" data-end=\"1481\"\u003ePhase: 3 Phase\u003c\/li\u003e\n\u003cli data-section-id=\"qw2yj0\" data-start=\"1482\" data-end=\"1553\"\u003eInterrupting Capacity:\n\u003cul data-start=\"1511\" data-end=\"1553\"\u003e\n\u003cli data-section-id=\"1vwgnt7\" data-start=\"1511\" data-end=\"1528\"\u003e35kA @ 480VAC\u003c\/li\u003e\n\u003cli data-section-id=\"14couht\" data-start=\"1531\" data-end=\"1553\"\u003e22kA @ 600Y\/347VAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1uohfrv\" data-start=\"1555\" data-end=\"1571\"\u003eConstruction\u003c\/h3\u003e\n\u003cul data-start=\"1573\" data-end=\"1823\"\u003e\n\u003cli data-section-id=\"ejvjyq\" data-start=\"1573\" data-end=\"1610\"\u003eEG frame molded case construction\u003c\/li\u003e\n\u003cli data-section-id=\"83r8w1\" data-start=\"1611\" data-end=\"1639\"\u003eFeed-thru breaker design\u003c\/li\u003e\n\u003cli data-section-id=\"10ro68j\" data-start=\"1640\" data-end=\"1675\"\u003eThermal-magnetic trip mechanism\u003c\/li\u003e\n\u003cli data-section-id=\"cqwfj8\" data-start=\"1676\" data-end=\"1722\"\u003eLine and load side lugs included (TA1EG10)\u003c\/li\u003e\n\u003cli data-section-id=\"on084j\" data-start=\"1723\" data-end=\"1786\"\u003eCopper\/aluminum compatible terminals (wire range 8–1\/0 AWG)\u003c\/li\u003e\n\u003cli data-section-id=\"1rjce7s\" data-start=\"1787\" data-end=\"1823\"\u003eIndustrial-grade durable housing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1bgavjr\" data-start=\"1825\" data-end=\"1838\"\u003eFunctions\u003c\/h3\u003e\n\u003cul data-start=\"1840\" data-end=\"1994\"\u003e\n\u003cli data-section-id=\"1hecu90\" data-start=\"1840\" data-end=\"1863\"\u003eOverload protection\u003c\/li\u003e\n\u003cli data-section-id=\"1ga7cu8\" data-start=\"1864\" data-end=\"1892\"\u003eShort-circuit protection\u003c\/li\u003e\n\u003cli data-section-id=\"3iwljf\" data-start=\"1893\" data-end=\"1923\"\u003eLong-time delay protection\u003c\/li\u003e\n\u003cli data-section-id=\"1van10e\" data-start=\"1924\" data-end=\"1958\"\u003eInstantaneous fault protection\u003c\/li\u003e\n\u003cli data-section-id=\"2m6ezl\" data-start=\"1959\" data-end=\"1994\"\u003eCircuit isolation and switching\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"bpec4l\" data-start=\"1996\" data-end=\"2010\"\u003eDimensions\u003c\/h3\u003e\n\u003cul data-start=\"2012\" data-end=\"2079\"\u003e\n\u003cli data-section-id=\"18c2g0u\" data-start=\"2012\" data-end=\"2028\"\u003eHeight: 3 in\u003c\/li\u003e\n\u003cli data-section-id=\"123du0q\" data-start=\"2029\" data-end=\"2046\"\u003eWidth: 5.5 in\u003c\/li\u003e\n\u003cli data-section-id=\"1kcsg3w\" data-start=\"2047\" data-end=\"2062\"\u003eDepth: 3 in\u003c\/li\u003e\n\u003cli data-section-id=\"18ra1fs\" data-start=\"2063\" data-end=\"2079\"\u003eWeight: 3 lb\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"w00lwu\" data-start=\"2081\" data-end=\"2094\"\u003eStandards\u003c\/h3\u003e\n\u003cul data-start=\"2096\" data-end=\"2126\"\u003e\n\u003cli data-section-id=\"11a7gqd\" data-start=\"2096\" data-end=\"2109\"\u003eUL Listed\u003c\/li\u003e\n\u003cli data-section-id=\"3h4a0l\" data-start=\"2110\" data-end=\"2126\"\u003eCSA Approved\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"wggvqn\" data-start=\"2128\" data-end=\"2144\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"2146\" data-end=\"2386\"\u003e\n\u003cli data-section-id=\"z8ij62\" data-start=\"2146\" data-end=\"2192\"\u003eIndustrial electrical distribution systems\u003c\/li\u003e\n\u003cli data-section-id=\"16ivz3w\" data-start=\"2193\" data-end=\"2236\"\u003eCommercial panelboards and switchboards\u003c\/li\u003e\n\u003cli data-section-id=\"cg27y0\" data-start=\"2237\" data-end=\"2273\"\u003eThree-phase low-voltage circuits\u003c\/li\u003e\n\u003cli data-section-id=\"f6bfax\" data-start=\"2274\" data-end=\"2305\"\u003eMotor and feeder protection\u003c\/li\u003e\n\u003cli data-section-id=\"1f09a34\" data-start=\"2306\" data-end=\"2343\"\u003eElectrical infrastructure systems\u003c\/li\u003e\n\u003cli data-section-id=\"fakth\" data-start=\"2344\" data-end=\"2386\"\u003eCompact high-interrupting applications\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens \/ ITE","offers":[{"title":"NEW","offer_id":48524846727417,"sku":"NEG3B015L","price":747.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/neg3b015l-New-1.jpg?v=1781278131","url":"https:\/\/mycircuitbreakers.com\/products\/siemens-neg3b015l-circuit-breaker-vl-series-eg-frame-15a-3-pole-600vac-feed-thru-thermal-magnetic","provider":"My Circuit Breakers","version":"1.0","type":"link"}