{"product_id":"siemens-q13000s01-circuit-breaker-qp-mp-series-30a-1-pole-120vac-plug-in-thermal-magnetic-shunt-trip","title":"Siemens Q13000S01 Circuit Breaker – QP\/MP Series – 30A – 1 Pole – 120VAC – Plug-In – Thermal Magnetic – Shunt Trip","description":"\u003cp data-start=\"136\" data-end=\"494\"\u003eThe Siemens Q13000S01 is a QP\/MP Series residential molded case circuit breaker designed for reliable branch circuit protection in load centers and electrical distribution panels. Rated at 30A and 120VAC, this 1-pole plug-in breaker is suitable for residential and light commercial applications requiring dependable overcurrent protection.\u003c\/p\u003e\n\u003cp data-start=\"496\" data-end=\"815\"\u003eThis breaker features a thermal-magnetic trip mechanism with Long-Time and Instantaneous (LI) functions for protection against overloads and short circuits. It also includes a factory-installed 120V shunt trip, allowing remote tripping capability for enhanced safety, emergency shutdowns, or control system integration.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1yl5694\" data-start=\"817\" data-end=\"835\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-start=\"837\" data-end=\"1223\"\u003e\n\u003cli data-section-id=\"abfwkk\" data-start=\"837\" data-end=\"855\"\u003eBrand: Siemens\u003c\/li\u003e\n\u003cli data-section-id=\"1oaqvrk\" data-start=\"856\" data-end=\"882\"\u003ePart Number: Q13000S01\u003c\/li\u003e\n\u003cli data-section-id=\"qtedae\" data-start=\"883\" data-end=\"907\"\u003eSeries: QP\/MP Series\u003c\/li\u003e\n\u003cli data-section-id=\"1mkdh5f\" data-start=\"908\" data-end=\"961\"\u003eCategory: Residential Molded Case Circuit Breaker\u003c\/li\u003e\n\u003cli data-section-id=\"l5l74u\" data-start=\"962\" data-end=\"977\"\u003eType: QP\/MP\u003c\/li\u003e\n\u003cli data-section-id=\"p7x2ge\" data-start=\"978\" data-end=\"1029\"\u003eMounting Type: Plug-In (Load Center Compatible)\u003c\/li\u003e\n\u003cli data-section-id=\"1re6uma\" data-start=\"1030\" data-end=\"1055\"\u003eConfiguration: 1 Pole\u003c\/li\u003e\n\u003cli data-section-id=\"vdhrok\" data-start=\"1056\" data-end=\"1074\"\u003ePhase: 1 Phase\u003c\/li\u003e\n\u003cli data-section-id=\"1vwficb\" data-start=\"1075\" data-end=\"1112\"\u003eProtection Type: Thermal Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"p0ct1o\" data-start=\"1113\" data-end=\"1165\"\u003eTrip Functions: LI – Long-Time and Instantaneous\u003c\/li\u003e\n\u003cli data-section-id=\"u2po26\" data-start=\"1166\" data-end=\"1202\"\u003eSpecial Feature: 120V Shunt Trip\u003c\/li\u003e\n\u003cli data-section-id=\"hjm9s2\" data-start=\"1203\" data-end=\"1223\"\u003eStandard: UL 489\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1v2p98c\" data-start=\"1225\" data-end=\"1247\"\u003eElectrical Ratings\u003c\/h3\u003e\n\u003cul data-start=\"1249\" data-end=\"1407\"\u003e\n\u003cli data-section-id=\"7spoqh\" data-start=\"1249\" data-end=\"1272\"\u003eCurrent Rating: 30A\u003c\/li\u003e\n\u003cli data-section-id=\"iegv07\" data-start=\"1273\" data-end=\"1299\"\u003eVoltage Rating: 120VAC\u003c\/li\u003e\n\u003cli data-section-id=\"17sscei\" data-start=\"1300\" data-end=\"1341\"\u003eInterrupting Capacity: 10 kA @ 120VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1pn6qhs\" data-start=\"1342\" data-end=\"1407\"\u003eApplication: Residential and light commercial branch circuits\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1uohfrv\" data-start=\"1409\" data-end=\"1425\"\u003eConstruction\u003c\/h3\u003e\n\u003cul data-start=\"1427\" data-end=\"1604\"\u003e\n\u003cli data-section-id=\"gjs8hx\" data-start=\"1427\" data-end=\"1457\"\u003eCompact molded case design\u003c\/li\u003e\n\u003cli data-section-id=\"86h388\" data-start=\"1458\" data-end=\"1507\"\u003ePlug-in installation for Siemens load centers\u003c\/li\u003e\n\u003cli data-section-id=\"5l4aem\" data-start=\"1508\" data-end=\"1538\"\u003eThermal-magnetic trip unit\u003c\/li\u003e\n\u003cli data-section-id=\"jajhb3\" data-start=\"1539\" data-end=\"1574\"\u003eIntegrated 120V shunt trip coil\u003c\/li\u003e\n\u003cli data-section-id=\"gt9k0u\" data-start=\"1575\" data-end=\"1604\"\u003eDurable insulated housing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1bgavjr\" data-start=\"1606\" data-end=\"1619\"\u003eFunctions\u003c\/h3\u003e\n\u003cul data-start=\"1621\" data-end=\"1749\"\u003e\n\u003cli data-section-id=\"1hecu90\" data-start=\"1621\" data-end=\"1644\"\u003eOverload protection\u003c\/li\u003e\n\u003cli data-section-id=\"1ga7cu8\" data-start=\"1645\" data-end=\"1673\"\u003eShort-circuit protection\u003c\/li\u003e\n\u003cli data-section-id=\"kckq32\" data-start=\"1674\" data-end=\"1713\"\u003eRemote trip capability (shunt trip)\u003c\/li\u003e\n\u003cli data-section-id=\"2m6ezl\" data-start=\"1714\" data-end=\"1749\"\u003eCircuit isolation and switching\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"wggvqn\" data-start=\"1751\" data-end=\"1767\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"1769\" data-end=\"1936\"\u003e\n\u003cli data-section-id=\"cfim03\" data-start=\"1769\" data-end=\"1797\"\u003eResidential load centers\u003c\/li\u003e\n\u003cli data-section-id=\"ilsnpg\" data-start=\"1798\" data-end=\"1834\"\u003eLighting and receptacle circuits\u003c\/li\u003e\n\u003cli data-section-id=\"1bql2z8\" data-start=\"1835\" data-end=\"1860\"\u003eHVAC control circuits\u003c\/li\u003e\n\u003cli data-section-id=\"43f15k\" data-start=\"1861\" data-end=\"1891\"\u003eEmergency shutdown systems\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens \/ ITE","offers":[{"title":"NEW","offer_id":48525124960505,"sku":"Q13000S01","price":110.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/q11500s01-1_10455907-a5b2-427f-bcb8-bcc5464fb4cc.webp?v=1781283679","url":"https:\/\/mycircuitbreakers.com\/products\/siemens-q13000s01-circuit-breaker-qp-mp-series-30a-1-pole-120vac-plug-in-thermal-magnetic-shunt-trip","provider":"My Circuit Breakers","version":"1.0","type":"link"}