{"product_id":"siemens-q220eg-circuit-breaker-qeb-series-20a-2-pole-120-240vac-plug-on-gfep-30ma-thermal-magnetic","title":"Siemens Q220EG Circuit Breaker – QEB Series – 20A – 2 Pole – 120\/240VAC – Plug-On – GFEP (30mA) – Thermal Magnetic","description":"\u003cp data-start=\"136\" data-end=\"550\"\u003eThe Siemens Q220EG is a QEB Series molded case circuit breaker designed for dedicated equipment protection where standard GFCI devices may cause nuisance tripping. Rated at 20A and 120\/240VAC, this 2-pole breaker provides ground-fault equipment protection (GFEP) with a 30mA trip threshold, making it suitable for industrial and commercial applications such as heat trace systems and pump loads.\u003c\/p\u003e\n\u003cp data-start=\"552\" data-end=\"919\"\u003eUnlike standard 5mA GFCI breakers used for personnel protection, the Q220EG is engineered specifically for equipment protection, allowing greater tolerance for normal leakage currents while still providing reliable fault detection. Its plug-on design allows direct installation into compatible Siemens load centers and serves as a replacement for legacy QE220 models.\u003c\/p\u003e\n\u003cp data-start=\"921\" data-end=\"1111\"\u003eThis breaker includes thermal-magnetic protection with Long-Time, Instantaneous, and Ground Fault (LIG) trip functions, along with a pigtail neutral connection for proper system integration.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1yl5694\" data-start=\"1113\" data-end=\"1131\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-start=\"1133\" data-end=\"1553\"\u003e\n\u003cli data-section-id=\"abfwkk\" data-start=\"1133\" data-end=\"1151\"\u003eBrand: Siemens\u003c\/li\u003e\n\u003cli data-section-id=\"fgp8zm\" data-start=\"1152\" data-end=\"1175\"\u003ePart Number: Q220EG\u003c\/li\u003e\n\u003cli data-section-id=\"1jh0goz\" data-start=\"1176\" data-end=\"1198\"\u003eSeries: QEB Series\u003c\/li\u003e\n\u003cli data-section-id=\"wzfkea\" data-start=\"1199\" data-end=\"1256\"\u003eCategory: Equipment Protection Circuit Breaker (GFEP)\u003c\/li\u003e\n\u003cli data-section-id=\"1plo1t4\" data-start=\"1257\" data-end=\"1308\"\u003eMounting Type: Plug-On (Load Center Compatible)\u003c\/li\u003e\n\u003cli data-section-id=\"utf2jl\" data-start=\"1309\" data-end=\"1334\"\u003eConfiguration: 2 Pole\u003c\/li\u003e\n\u003cli data-section-id=\"vdhrok\" data-start=\"1335\" data-end=\"1353\"\u003ePhase: 1 Phase\u003c\/li\u003e\n\u003cli data-section-id=\"pf015r\" data-start=\"1354\" data-end=\"1406\"\u003eProtection Type: Thermal Magnetic + Ground Fault\u003c\/li\u003e\n\u003cli data-section-id=\"1yzk00z\" data-start=\"1407\" data-end=\"1475\"\u003eTrip Function Code: LIG (Long-Time, Instantaneous, Ground Fault)\u003c\/li\u003e\n\u003cli data-section-id=\"1tswodb\" data-start=\"1476\" data-end=\"1520\"\u003eTrip Level: 30mA Ground Fault Protection\u003c\/li\u003e\n\u003cli data-section-id=\"2hwz6r\" data-start=\"1521\" data-end=\"1553\"\u003eStandard: UL 489 \/ CSA C22.2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1v2p98c\" data-start=\"1555\" data-end=\"1577\"\u003eElectrical Ratings\u003c\/h3\u003e\n\u003cul data-start=\"1579\" data-end=\"1737\"\u003e\n\u003cli data-section-id=\"7s1ptk\" data-start=\"1579\" data-end=\"1602\"\u003eCurrent Rating: 20A\u003c\/li\u003e\n\u003cli data-section-id=\"1aud41a\" data-start=\"1603\" data-end=\"1633\"\u003eVoltage Rating: 120\/240VAC\u003c\/li\u003e\n\u003cli data-section-id=\"zrk0pf\" data-start=\"1634\" data-end=\"1679\"\u003eInterrupting Capacity: 10 kA @ 120\/240VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1vjh4vl\" data-start=\"1680\" data-end=\"1737\"\u003eApplication: Equipment ground-fault protection (GFEP)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1uohfrv\" data-start=\"1739\" data-end=\"1755\"\u003eConstruction\u003c\/h3\u003e\n\u003cul data-start=\"1757\" data-end=\"1968\"\u003e\n\u003cli data-section-id=\"tj92lc\" data-start=\"1757\" data-end=\"1787\"\u003ePlug-on molded case design\u003c\/li\u003e\n\u003cli data-section-id=\"w397tu\" data-start=\"1788\" data-end=\"1818\"\u003ePigtail neutral connection\u003c\/li\u003e\n\u003cli data-section-id=\"66fucf\" data-start=\"1819\" data-end=\"1861\"\u003eIntegrated ground-fault sensing (30mA)\u003c\/li\u003e\n\u003cli data-section-id=\"10ro68j\" data-start=\"1862\" data-end=\"1897\"\u003eThermal-magnetic trip mechanism\u003c\/li\u003e\n\u003cli data-section-id=\"bt4f4s\" data-start=\"1898\" data-end=\"1938\"\u003eSelf-test and visual trip indication\u003c\/li\u003e\n\u003cli data-section-id=\"gt9k0u\" data-start=\"1939\" data-end=\"1968\"\u003eDurable insulated housing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1bgavjr\" data-start=\"1970\" data-end=\"1983\"\u003eFunctions\u003c\/h3\u003e\n\u003cul data-start=\"1985\" data-end=\"2141\"\u003e\n\u003cli data-section-id=\"1hecu90\" data-start=\"1985\" data-end=\"2008\"\u003eOverload protection\u003c\/li\u003e\n\u003cli data-section-id=\"1ga7cu8\" data-start=\"2009\" data-end=\"2037\"\u003eShort-circuit protection\u003c\/li\u003e\n\u003cli data-section-id=\"1ja0quc\" data-start=\"2038\" data-end=\"2075\"\u003eGround-fault equipment protection\u003c\/li\u003e\n\u003cli data-section-id=\"3iwljf\" data-start=\"2076\" data-end=\"2106\"\u003eLong-time delay protection\u003c\/li\u003e\n\u003cli data-section-id=\"1van10e\" data-start=\"2107\" data-end=\"2141\"\u003eInstantaneous fault protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"wggvqn\" data-start=\"2143\" data-end=\"2159\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"2161\" data-end=\"2374\"\u003e\n\u003cli data-section-id=\"2fzkjt\" data-start=\"2161\" data-end=\"2189\"\u003eHeat trace cable systems\u003c\/li\u003e\n\u003cli data-section-id=\"gcw568\" data-start=\"2190\" data-end=\"2221\"\u003eIndustrial pumps and motors\u003c\/li\u003e\n\u003cli data-section-id=\"19byqf9\" data-start=\"2222\" data-end=\"2251\"\u003eCommercial HVAC equipment\u003c\/li\u003e\n\u003cli data-section-id=\"18gq5tz\" data-start=\"2252\" data-end=\"2282\"\u003eFreeze protection circuits\u003c\/li\u003e\n\u003cli data-section-id=\"rfvgqe\" data-start=\"2283\" data-end=\"2332\"\u003eSensitive equipment requiring GFEP protection\u003c\/li\u003e\n\u003cli data-section-id=\"8uxthl\" data-start=\"2333\" data-end=\"2374\"\u003eLegacy QE220 replacement applications\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens \/ ITE","offers":[{"title":"NEW","offer_id":48525251215609,"sku":"Q220EG","price":231.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/Q220EG-2-Pole-Ground-Fault-Circuit-Breaker_Siemens_1.webp?v=1781286435","url":"https:\/\/mycircuitbreakers.com\/products\/siemens-q220eg-circuit-breaker-qeb-series-20a-2-pole-120-240vac-plug-on-gfep-30ma-thermal-magnetic","provider":"My Circuit Breakers","version":"1.0","type":"link"}