{"product_id":"siemens-qf260ah-circuit-breaker-qf-series-60a-2-pole-120-240vac-gfci-plug-on-22kaic","title":"Siemens QF260AH Circuit Breaker – QF Series – 60A – 2 Pole – 120\/240VAC – GFCI – Plug-On – 22kAIC","description":"\u003cp data-start=\"119\" data-end=\"571\"\u003eThe Siemens QF260AH is a QF Series Ground Fault Circuit Interrupter (GFCI) circuit breaker engineered for applications requiring enhanced personnel protection and high short-circuit interruption capability. Rated at 60A and 120\/240VAC, this 2-pole breaker provides Class A 5mA ground-fault protection and a robust 22kA interrupting capacity, making it ideal for spas, pools, hot tubs, HVAC systems, and other demanding installations.\u003c\/p\u003e\n\u003cp data-start=\"573\" data-end=\"984\"\u003eDesigned to meet modern electrical safety requirements, the QF260AH features an integrated self-test function that continuously monitors breaker operation and ground-fault protection readiness. The plug-on design and pigtail neutral wire allow for easy installation in compatible Siemens load centers, while the HACR-rated construction supports heating, ventilation, and air conditioning equipment applications.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1yl5694\" data-start=\"986\" data-end=\"1004\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-start=\"1006\" data-end=\"1489\"\u003e\n\u003cli data-section-id=\"abfwkk\" data-start=\"1006\" data-end=\"1024\"\u003eBrand: Siemens\u003c\/li\u003e\n\u003cli data-section-id=\"ob2cej\" data-start=\"1025\" data-end=\"1049\"\u003ePart Number: QF260AH\u003c\/li\u003e\n\u003cli data-section-id=\"47ihcy\" data-start=\"1050\" data-end=\"1071\"\u003eSeries: QF Series\u003c\/li\u003e\n\u003cli data-section-id=\"i13v94\" data-start=\"1072\" data-end=\"1141\"\u003eCategory: Ground Fault Circuit Interrupter (GFCI) Circuit Breaker\u003c\/li\u003e\n\u003cli data-section-id=\"prk18n\" data-start=\"1142\" data-end=\"1184\"\u003eSpecial Classification: GFCI (Class A)\u003c\/li\u003e\n\u003cli data-section-id=\"kzuk02\" data-start=\"1185\" data-end=\"1211\"\u003eMounting Type: Plug-On\u003c\/li\u003e\n\u003cli data-section-id=\"utf2jl\" data-start=\"1212\" data-end=\"1237\"\u003eConfiguration: 2 Pole\u003c\/li\u003e\n\u003cli data-section-id=\"vdhrok\" data-start=\"1238\" data-end=\"1256\"\u003ePhase: 1 Phase\u003c\/li\u003e\n\u003cli data-section-id=\"145fmt1\" data-start=\"1257\" data-end=\"1323\"\u003eProtection Type: Thermal Magnetic with Ground Fault Protection\u003c\/li\u003e\n\u003cli data-section-id=\"8epttz\" data-start=\"1324\" data-end=\"1351\"\u003eTrip Function Code: LIG\u003c\/li\u003e\n\u003cli data-section-id=\"1rn699a\" data-start=\"1352\" data-end=\"1410\"\u003eTrip Functions: Long-Time, Instantaneous, Ground Fault\u003c\/li\u003e\n\u003cli data-section-id=\"rn4aoz\" data-start=\"1411\" data-end=\"1440\"\u003eTrip Adjustability: Fixed\u003c\/li\u003e\n\u003cli data-section-id=\"17k82km\" data-start=\"1441\" data-end=\"1489\"\u003eStandards: UL 489, UL 943, CSA C22.2 No. 144\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1v2p98c\" data-start=\"1491\" data-end=\"1513\"\u003eElectrical Ratings\u003c\/h3\u003e\n\u003cul data-start=\"1515\" data-end=\"1686\"\u003e\n\u003cli data-section-id=\"7uve2k\" data-start=\"1515\" data-end=\"1538\"\u003eCurrent Rating: 60A\u003c\/li\u003e\n\u003cli data-section-id=\"1aud41a\" data-start=\"1539\" data-end=\"1569\"\u003eVoltage Rating: 120\/240VAC\u003c\/li\u003e\n\u003cli data-section-id=\"epx9xu\" data-start=\"1570\" data-end=\"1614\"\u003eInterrupting Capacity: 22kA @ 120\/240VAC\u003c\/li\u003e\n\u003cli data-section-id=\"hli0pw\" data-start=\"1615\" data-end=\"1657\"\u003eGround Fault Trip Level: 5mA (Class A)\u003c\/li\u003e\n\u003cli data-section-id=\"stfxxl\" data-start=\"1658\" data-end=\"1686\"\u003eTemperature Rating: 40°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1uohfrv\" data-start=\"1688\" data-end=\"1704\"\u003eConstruction\u003c\/h3\u003e\n\u003cul data-start=\"1706\" data-end=\"1978\"\u003e\n\u003cli data-section-id=\"ghebma\" data-start=\"1706\" data-end=\"1733\"\u003ePlug-on mounting design\u003c\/li\u003e\n\u003cli data-section-id=\"1y0885n\" data-start=\"1734\" data-end=\"1769\"\u003ePigtail neutral wire connection\u003c\/li\u003e\n\u003cli data-section-id=\"10ro68j\" data-start=\"1770\" data-end=\"1805\"\u003eThermal-magnetic trip mechanism\u003c\/li\u003e\n\u003cli data-section-id=\"1bw8syn\" data-start=\"1806\" data-end=\"1844\"\u003eIntegrated Class A GFCI protection\u003c\/li\u003e\n\u003cli data-section-id=\"8aj201\" data-start=\"1845\" data-end=\"1880\"\u003eAutomatic self-test diagnostics\u003c\/li\u003e\n\u003cli data-section-id=\"1mgl5pr\" data-start=\"1881\" data-end=\"1924\"\u003eHigh interrupting capacity construction\u003c\/li\u003e\n\u003cli data-section-id=\"64up4e\" data-start=\"1925\" data-end=\"1946\"\u003eHACR-rated design\u003c\/li\u003e\n\u003cli data-section-id=\"177ppp4\" data-start=\"1947\" data-end=\"1978\"\u003eDurable molded case housing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"zk9b8x\" data-start=\"1980\" data-end=\"2007\"\u003eConductor Compatibility\u003c\/h3\u003e\n\u003cul data-start=\"2009\" data-end=\"2147\"\u003e\n\u003cli data-section-id=\"10ae4t2\" data-start=\"2009\" data-end=\"2039\"\u003eCopper Wire Range: 8–4 AWG\u003c\/li\u003e\n\u003cli data-section-id=\"ka9t8h\" data-start=\"2040\" data-end=\"2072\"\u003eAluminum Wire Range: 8–2 AWG\u003c\/li\u003e\n\u003cli data-section-id=\"gyxqxy\" data-start=\"2073\" data-end=\"2101\"\u003eMinimum Wire Size: 8 AWG\u003c\/li\u003e\n\u003cli data-section-id=\"pprclc\" data-start=\"2102\" data-end=\"2147\"\u003eMaximum Wire Size: 4 AWG (Cu), 2 AWG (Al)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1bgavjr\" data-start=\"2149\" data-end=\"2162\"\u003eFunctions\u003c\/h3\u003e\n\u003cul data-start=\"2164\" data-end=\"2412\"\u003e\n\u003cli data-section-id=\"1cpsbbf\" data-start=\"2164\" data-end=\"2215\"\u003eClass A personnel ground-fault protection (5mA)\u003c\/li\u003e\n\u003cli data-section-id=\"1hecu90\" data-start=\"2216\" data-end=\"2239\"\u003eOverload protection\u003c\/li\u003e\n\u003cli data-section-id=\"1ga7cu8\" data-start=\"2240\" data-end=\"2268\"\u003eShort-circuit protection\u003c\/li\u003e\n\u003cli data-section-id=\"1llesa2\" data-start=\"2269\" data-end=\"2311\"\u003eAutomatic self-testing and diagnostics\u003c\/li\u003e\n\u003cli data-section-id=\"3iwljf\" data-start=\"2312\" data-end=\"2342\"\u003eLong-time delay protection\u003c\/li\u003e\n\u003cli data-section-id=\"1van10e\" data-start=\"2343\" data-end=\"2377\"\u003eInstantaneous fault protection\u003c\/li\u003e\n\u003cli data-section-id=\"1g1enhq\" data-start=\"2378\" data-end=\"2412\"\u003eSimultaneous two-pole tripping\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"wggvqn\" data-start=\"2414\" data-end=\"2430\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"2432\" data-end=\"2683\"\u003e\n\u003cli data-section-id=\"u383n8\" data-start=\"2432\" data-end=\"2459\"\u003eSwimming pool equipment\u003c\/li\u003e\n\u003cli data-section-id=\"uomye\" data-start=\"2460\" data-end=\"2481\"\u003eSpas and hot tubs\u003c\/li\u003e\n\u003cli data-section-id=\"866agm\" data-start=\"2482\" data-end=\"2518\"\u003eOutdoor electrical installations\u003c\/li\u003e\n\u003cli data-section-id=\"xhdvo4\" data-start=\"2519\" data-end=\"2545\"\u003eDamp and wet locations\u003c\/li\u003e\n\u003cli data-section-id=\"qksyop\" data-start=\"2546\" data-end=\"2573\"\u003eHVAC equipment circuits\u003c\/li\u003e\n\u003cli data-section-id=\"1cxj66\" data-start=\"2574\" data-end=\"2628\"\u003eSiemens EQ, EQL, SEQ, EQG, PL, and ES load centers\u003c\/li\u003e\n\u003cli data-section-id=\"sbareu\" data-start=\"2629\" data-end=\"2683\"\u003eResidential and commercial GFCI-protected circuits\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1siptvj\" data-start=\"2685\" data-end=\"2715\"\u003eCertifications \u0026amp; Approvals\u003c\/h3\u003e\n\u003cul data-start=\"2717\" data-end=\"2789\"\u003e\n\u003cli data-section-id=\"11a7gqd\" data-start=\"2717\" data-end=\"2730\"\u003eUL Listed\u003c\/li\u003e\n\u003cli data-section-id=\"1ygh62h\" data-start=\"2731\" data-end=\"2748\"\u003eCSA Certified\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens \/ ITE","offers":[{"title":"NEW","offer_id":48525359284473,"sku":"QF260AH","price":266.0,"currency_code":"USD","in_stock":true}],"url":"https:\/\/mycircuitbreakers.com\/products\/siemens-qf260ah-circuit-breaker-qf-series-60a-2-pole-120-240vac-gfci-plug-on-22kaic","provider":"My Circuit Breakers","version":"1.0","type":"link"}