{"product_id":"siemens-slvbr4640-fusible-bus-plug-sentron-low-amp-series-200a-3-phase-4-wire-600vac-riser-orientation-100kaic","title":"Siemens SLVBR4640 Fusible Bus Plug – Sentron Low-Amp Series – 200A – 3 Phase 4 Wire – 600VAC – Riser Orientation – 100kAIC","description":"\u003cp data-start=\"146\" data-end=\"497\"\u003eThe Siemens SLVBR4640 is a Sentron Low-Amp series heavy-duty fusible bus plug designed for Siemens busway power distribution systems. Manufactured by \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eSiemens Breakers\u003c\/span\u003e\u003c\/span\u003e, it provides a reliable tap-off connection for commercial and industrial electrical installations requiring high-performance power distribution.\u003c\/p\u003e\n\u003cp data-start=\"499\" data-end=\"813\"\u003eThis bus plug features a riser orientation design and is rated for 200A at 600VAC. Engineered for use in 3-phase, 4-wire systems, it delivers dependable overcurrent protection and safe power distribution in demanding applications. The IP40 enclosure rating helps protect internal components in indoor environments.\u003c\/p\u003e\n\u003ch3 data-section-id=\"e5mrjc\" data-start=\"815\" data-end=\"835\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-start=\"837\" data-end=\"1192\"\u003e\n\u003cli data-section-id=\"abfwkk\" data-start=\"837\" data-end=\"855\"\u003eBrand: Siemens\u003c\/li\u003e\n\u003cli data-section-id=\"1cbt5xb\" data-start=\"856\" data-end=\"911\"\u003eManufacturer: \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eSiemens Breakers\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1nthkwu\" data-start=\"912\" data-end=\"938\"\u003ePart Number: SLVBR4640\u003c\/li\u003e\n\u003cli data-section-id=\"lof5n8\" data-start=\"939\" data-end=\"966\"\u003eSeries: Sentron Low-Amp\u003c\/li\u003e\n\u003cli data-section-id=\"16cqk99\" data-start=\"967\" data-end=\"997\"\u003eCategory: Fusible Bus Plug\u003c\/li\u003e\n\u003cli data-section-id=\"7ouo44\" data-start=\"998\" data-end=\"1013\"\u003eType: SLVBR\u003c\/li\u003e\n\u003cli data-section-id=\"145yoqw\" data-start=\"1014\" data-end=\"1048\"\u003eConfiguration: 3 Phase, 4 Wire\u003c\/li\u003e\n\u003cli data-section-id=\"1pcpnvg\" data-start=\"1049\" data-end=\"1071\"\u003eOrientation: Riser\u003c\/li\u003e\n\u003cli data-section-id=\"17jx6g8\" data-start=\"1072\" data-end=\"1096\"\u003eCurrent Rating: 200A\u003c\/li\u003e\n\u003cli data-section-id=\"1t5slu\" data-start=\"1097\" data-end=\"1123\"\u003eVoltage Rating: 600VAC\u003c\/li\u003e\n\u003cli data-section-id=\"192lncl\" data-start=\"1124\" data-end=\"1165\"\u003eInterrupting Capacity: 100kA @ 480VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1602mol\" data-start=\"1166\" data-end=\"1192\"\u003eEnclosure Rating: IP40\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"l2e26z\" data-start=\"1194\" data-end=\"1212\"\u003eConstruction\u003c\/h3\u003e\n\u003cul data-start=\"1214\" data-end=\"1510\"\u003e\n\u003cli data-section-id=\"o05w7z\" data-start=\"1214\" data-end=\"1250\"\u003eHeavy-duty fusible switch design\u003c\/li\u003e\n\u003cli data-section-id=\"mllf86\" data-start=\"1251\" data-end=\"1286\"\u003eRiser orientation configuration\u003c\/li\u003e\n\u003cli data-section-id=\"khnu4q\" data-start=\"1287\" data-end=\"1342\"\u003eDesigned for Siemens Sentron Low-Amp busway systems\u003c\/li\u003e\n\u003cli data-section-id=\"14mp7o7\" data-start=\"1343\" data-end=\"1386\"\u003eIndustrial-grade enclosure construction\u003c\/li\u003e\n\u003cli data-section-id=\"1docmjw\" data-start=\"1387\" data-end=\"1435\"\u003eIntegrated overcurrent protection capability\u003c\/li\u003e\n\u003cli data-section-id=\"1yk6mhl\" data-start=\"1436\" data-end=\"1510\"\u003eSuitable for commercial and industrial power distribution applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1i6jv5v\" data-start=\"1512\" data-end=\"1537\"\u003eDimensions \u0026amp; Weight\u003c\/h3\u003e\n\u003cul data-start=\"1539\" data-end=\"1590\"\u003e\n\u003cli data-section-id=\"1viso8e\" data-start=\"1539\" data-end=\"1560\"\u003eWeight: 66.139 lb\u003c\/li\u003e\n\u003cli data-section-id=\"1sakj0h\" data-start=\"1561\" data-end=\"1590\"\u003eDimensions: Not specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"17tovxr\" data-start=\"1592\" data-end=\"1610\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"1612\" data-end=\"1894\"\u003e\n\u003cli data-section-id=\"xyxmvk\" data-start=\"1612\" data-end=\"1660\"\u003eIndustrial busway power distribution systems\u003c\/li\u003e\n\u003cli data-section-id=\"76q75m\" data-start=\"1661\" data-end=\"1701\"\u003eCommercial electrical infrastructure\u003c\/li\u003e\n\u003cli data-section-id=\"6llraw\" data-start=\"1702\" data-end=\"1752\"\u003eManufacturing facilities and processing plants\u003c\/li\u003e\n\u003cli data-section-id=\"wocg7l\" data-start=\"1753\" data-end=\"1801\"\u003eData centers and critical power applications\u003c\/li\u003e\n\u003cli data-section-id=\"1uj175k\" data-start=\"1802\" data-end=\"1843\"\u003eBusway tap-off and feeder connections\u003c\/li\u003e\n\u003cli data-section-id=\"1eckdwh\" data-start=\"1844\" data-end=\"1894\"\u003eHigh-capacity electrical distribution networks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"cmyhz3\" data-start=\"1896\" data-end=\"1928\"\u003eCertifications \u0026amp; Approvals\u003c\/h3\u003e\n\u003cul data-start=\"1930\" data-end=\"2131\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\n\u003cli data-section-id=\"3h4a0l\" data-start=\"1930\" data-end=\"1946\"\u003eCSA Approved\u003c\/li\u003e\n\u003cli data-section-id=\"khnu4q\" data-start=\"1947\" data-end=\"2002\"\u003eDesigned for Siemens Sentron Low-Amp busway systems\u003c\/li\u003e\n\u003cli data-section-id=\"gleecl\" data-start=\"2003\" data-end=\"2070\"\u003eSuitable for UL-compliant electrical distribution installations\u003c\/li\u003e\n\u003cli data-section-id=\"167ka4u\" data-start=\"2071\" data-end=\"2131\" data-is-last-node=\"\"\u003eHigh interrupting capacity for enhanced fault protection\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens \/ ITE","offers":[{"title":"NEW","offer_id":48526178353401,"sku":"SLVBR4640","price":2818.13,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/SLVBR4640-All-New-1_97cd70cd-60bc-4f3f-9f9a-b70aa8115fdc.webp?v=1781337850","url":"https:\/\/mycircuitbreakers.com\/products\/siemens-slvbr4640-fusible-bus-plug-sentron-low-amp-series-200a-3-phase-4-wire-600vac-riser-orientation-100kaic","provider":"My Circuit Breakers","version":"1.0","type":"link"}