{"product_id":"square-d-bda2100y2-powerpact-b-circuit-breaker-2-pole-100a-thermal-magnetic-i-line-18ka-480vac","title":"Square D BDA2100Y2 PowerPact B Circuit Breaker – 2 Pole – 100A – Thermal Magnetic – I-Line – 18kA @ 480VAC","description":"\u003cp data-start=\"130\" data-end=\"531\"\u003eThe Square D BDA2100Y2 is a PowerPact B-frame molded case circuit breaker designed to provide dependable overcurrent protection in commercial and industrial power distribution systems. Manufactured by Schneider Electric, this 2-pole breaker features fixed thermal-magnetic trip technology, delivering Long-Time and Instantaneous (LI) protection against overloads and short circuits.\u003c\/p\u003e\n\u003cp data-start=\"533\" data-end=\"962\"\u003eRated at 100A, the breaker utilizes an I-Line mounting configuration for quick installation into compatible Square D I-Line panelboards and switchboards. Its current-limiting design helps reduce fault energy, while the visual trip indicator simplifies troubleshooting and maintenance. The BDA2100Y2 also serves as a direct replacement for legacy FA24100AC breakers, making it an ideal upgrade solution for existing installations.\u003c\/p\u003e\n\u003ch3 data-section-id=\"e5mrjc\" data-start=\"964\" data-end=\"984\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-start=\"986\" data-end=\"1259\"\u003e\n\u003cli data-section-id=\"1ii30bw\" data-start=\"986\" data-end=\"1005\"\u003eBrand: Square D\u003c\/li\u003e\n\u003cli data-section-id=\"1mzzcj3\" data-start=\"1006\" data-end=\"1042\"\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n\u003cli data-section-id=\"1gl0r38\" data-start=\"1043\" data-end=\"1078\"\u003eSeries: BDA (PowerPact B-Frame)\u003c\/li\u003e\n\u003cli data-section-id=\"524pt5\" data-start=\"1079\" data-end=\"1105\"\u003ePart Number: BDA2100Y2\u003c\/li\u003e\n\u003cli data-section-id=\"6rlgrk\" data-start=\"1106\" data-end=\"1150\"\u003eType: Molded Case Circuit Breaker (MCCB)\u003c\/li\u003e\n\u003cli data-section-id=\"ksyb51\" data-start=\"1151\" data-end=\"1163\"\u003ePoles: 2\u003c\/li\u003e\n\u003cli data-section-id=\"11x0coz\" data-start=\"1164\" data-end=\"1182\"\u003ePhase: 1 Phase\u003c\/li\u003e\n\u003cli data-section-id=\"z6pr2l\" data-start=\"1183\" data-end=\"1208\"\u003eAmperage Rating: 100A\u003c\/li\u003e\n\u003cli data-section-id=\"wh7dqa\" data-start=\"1209\" data-end=\"1235\"\u003eMounting Style: I-Line\u003c\/li\u003e\n\u003cli data-section-id=\"fl0tfn\" data-start=\"1236\" data-end=\"1259\"\u003eTerminal Type: Lugs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"oy7toc\" data-start=\"1261\" data-end=\"1285\"\u003eElectrical Ratings\u003c\/h3\u003e\n\u003cul data-start=\"1287\" data-end=\"1525\"\u003e\n\u003cli data-section-id=\"1y7729n\" data-start=\"1287\" data-end=\"1381\"\u003eVoltage Rating:\n\u003cul data-start=\"1309\" data-end=\"1381\"\u003e\n\u003cli data-section-id=\"1uqein7\" data-start=\"1309\" data-end=\"1324\"\u003e208Y\/120VAC\u003c\/li\u003e\n\u003cli data-section-id=\"guirai\" data-start=\"1327\" data-end=\"1337\"\u003e240VAC\u003c\/li\u003e\n\u003cli data-section-id=\"evl76s\" data-start=\"1340\" data-end=\"1355\"\u003e480Y\/277VAC\u003c\/li\u003e\n\u003cli data-section-id=\"10ayli8\" data-start=\"1358\" data-end=\"1368\"\u003e480VAC\u003c\/li\u003e\n\u003cli data-section-id=\"8locpa\" data-start=\"1371\" data-end=\"1381\"\u003e250VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1y6i3nw\" data-start=\"1383\" data-end=\"1525\"\u003eInterrupting Capacity (AIC):\n\u003cul data-start=\"1418\" data-end=\"1525\"\u003e\n\u003cli data-section-id=\"1apgsoe\" data-start=\"1418\" data-end=\"1440\"\u003e25kA @ 208Y\/120VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1hxk5s7\" data-start=\"1443\" data-end=\"1460\"\u003e25kA @ 240VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1466qyv\" data-start=\"1463\" data-end=\"1485\"\u003e18kA @ 480Y\/277VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1d6wag3\" data-start=\"1488\" data-end=\"1505\"\u003e18kA @ 480VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1gb0c1x\" data-start=\"1508\" data-end=\"1525\"\u003e10kA @ 250VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"5b7pht\" data-start=\"1527\" data-end=\"1557\"\u003eTrip Unit Specifications\u003c\/h3\u003e\n\u003cul data-start=\"1559\" data-end=\"1781\"\u003e\n\u003cli data-section-id=\"2puffi\" data-start=\"1559\" data-end=\"1596\"\u003eTrip Technology: Thermal Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"5ed487\" data-start=\"1597\" data-end=\"1623\"\u003eTrip Function Code: LI\u003c\/li\u003e\n\u003cli data-section-id=\"1fmsb4q\" data-start=\"1624\" data-end=\"1668\"\u003eTrip Functions: Long-Time, Instantaneous\u003c\/li\u003e\n\u003cli data-section-id=\"1crqvqj\" data-start=\"1669\" data-end=\"1722\"\u003eTrip Adjustability: Fixed Thermal, Fixed Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"1u4l8dh\" data-start=\"1723\" data-end=\"1781\"\u003eProtection Type: Overload and Short-Circuit Protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"kxa3y3\" data-start=\"1783\" data-end=\"1802\"\u003eWire Capacity\u003c\/h3\u003e\n\u003cul data-start=\"1804\" data-end=\"1960\"\u003e\n\u003cli data-section-id=\"679nd3\" data-start=\"1804\" data-end=\"1842\"\u003eConductor Range: 14 AWG to 2\/0 AWG\u003c\/li\u003e\n\u003cli data-section-id=\"u6eem7\" data-start=\"1843\" data-end=\"1899\"\u003eCompatible Conductors: Copper (Cu) and Aluminum (Al)\u003c\/li\u003e\n\u003cli data-section-id=\"431q5m\" data-start=\"1900\" data-end=\"1930\"\u003eMaximum Wire Size: 2\/0 AWG\u003c\/li\u003e\n\u003cli data-section-id=\"1j655zw\" data-start=\"1931\" data-end=\"1960\"\u003eMinimum Wire Size: 14 AWG\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"337yl8\" data-start=\"1962\" data-end=\"1989\"\u003eConstruction Features\u003c\/h3\u003e\n\u003cul data-start=\"1991\" data-end=\"2170\"\u003e\n\u003cli data-section-id=\"ixfkiz\" data-start=\"1991\" data-end=\"2018\"\u003eCurrent-Limiting Design\u003c\/li\u003e\n\u003cli data-section-id=\"k2kph2\" data-start=\"2019\" data-end=\"2033\"\u003eHACR Rated\u003c\/li\u003e\n\u003cli data-section-id=\"3c8pia\" data-start=\"2034\" data-end=\"2059\"\u003eVisual Trip Indicator\u003c\/li\u003e\n\u003cli data-section-id=\"1g7bc3y\" data-start=\"2060\" data-end=\"2095\"\u003eAC Phase Connection (Y2 Suffix)\u003c\/li\u003e\n\u003cli data-section-id=\"exwh6h\" data-start=\"2096\" data-end=\"2138\"\u003eCompact PowerPact B-Frame Construction\u003c\/li\u003e\n\u003cli data-section-id=\"ys9p5o\" data-start=\"2139\" data-end=\"2170\"\u003eI-Line Plug-On Installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"5bmdbt\" data-start=\"2172\" data-end=\"2199\"\u003eAvailable Accessories\u003c\/h3\u003e\n\u003cul data-start=\"2201\" data-end=\"2338\"\u003e\n\u003cli data-section-id=\"1is1mo3\" data-start=\"2201\" data-end=\"2215\"\u003eShunt Trip\u003c\/li\u003e\n\u003cli data-section-id=\"i91omo\" data-start=\"2216\" data-end=\"2236\"\u003eAuxiliary Switch\u003c\/li\u003e\n\u003cli data-section-id=\"1jdu86j\" data-start=\"2237\" data-end=\"2261\"\u003eUndervoltage Release\u003c\/li\u003e\n\u003cli data-section-id=\"188ml0p\" data-start=\"2262\" data-end=\"2278\"\u003eAlarm Switch\u003c\/li\u003e\n\u003cli data-section-id=\"1c1t4i7\" data-start=\"2279\" data-end=\"2301\"\u003ePadlock Attachment\u003c\/li\u003e\n\u003cli data-section-id=\"riy5i9\" data-start=\"2302\" data-end=\"2319\"\u003eRotary Handle\u003c\/li\u003e\n\u003cli data-section-id=\"1aqwu83\" data-start=\"2320\" data-end=\"2338\"\u003eMotor Operator\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"q67t74\" data-start=\"2340\" data-end=\"2374\"\u003eEnvironmental Specifications\u003c\/h3\u003e\n\u003cul data-start=\"2376\" data-end=\"2416\"\u003e\n\u003cli data-section-id=\"1at0y7p\" data-start=\"2376\" data-end=\"2416\"\u003eOperating Temperature: -25°C to 70°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"17tovxr\" data-start=\"2418\" data-end=\"2436\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"2438\" data-end=\"2656\"\u003e\n\u003cli data-section-id=\"1e2izfc\" data-start=\"2438\" data-end=\"2469\"\u003eSquare D I-Line Panelboards\u003c\/li\u003e\n\u003cli data-section-id=\"1tbswuu\" data-start=\"2470\" data-end=\"2495\"\u003eSquare D Switchboards\u003c\/li\u003e\n\u003cli data-section-id=\"ephhtz\" data-start=\"2496\" data-end=\"2537\"\u003eCommercial Power Distribution Systems\u003c\/li\u003e\n\u003cli data-section-id=\"1pzb5e5\" data-start=\"2538\" data-end=\"2567\"\u003eIndustrial Control Panels\u003c\/li\u003e\n\u003cli data-section-id=\"1e3kvy5\" data-start=\"2568\" data-end=\"2597\"\u003eHVAC Equipment Protection\u003c\/li\u003e\n\u003cli data-section-id=\"ujupcc\" data-start=\"2598\" data-end=\"2627\"\u003eBranch Circuit Protection\u003c\/li\u003e\n\u003cli data-section-id=\"2hrv3f\" data-start=\"2628\" data-end=\"2656\"\u003eOEM Electrical Equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"174ui70\" data-start=\"2658\" data-end=\"2685\"\u003eStandards \u0026amp; Approvals\u003c\/h3\u003e\n\u003cul data-start=\"2687\" data-end=\"2800\"\u003e\n\u003cli data-section-id=\"6d8czo\" data-start=\"2687\" data-end=\"2697\"\u003eUL 489\u003c\/li\u003e\n\u003cli data-section-id=\"12xbscc\" data-start=\"2698\" data-end=\"2717\"\u003eCSA C22.2 No. 5\u003c\/li\u003e\n\u003cli data-section-id=\"1a1r7gg\" data-start=\"2718\" data-end=\"2736\"\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003cli data-section-id=\"1yfaqpn\" data-start=\"2737\" data-end=\"2757\"\u003eEN\/IEC 60947-5-1\u003c\/li\u003e\n\u003cli data-section-id=\"11cuwal\" data-start=\"2758\" data-end=\"2771\"\u003eNEMA AB 1\u003c\/li\u003e\n\u003cli data-section-id=\"1a71x6w\" data-start=\"2772\" data-end=\"2786\"\u003eGB 14048.2\u003c\/li\u003e\n\u003cli data-section-id=\"ewodza\" data-start=\"2787\" data-end=\"2800\"\u003eNMX J-266\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2802\" data-end=\"2818\"\u003e\u003cstrong data-start=\"2802\" data-end=\"2816\"\u003eApprovals:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2819\" data-end=\"2934\"\u003e\n\u003cli data-section-id=\"1w9xzw2\" data-start=\"2819\" data-end=\"2832\"\u003eUL Listed\u003c\/li\u003e\n\u003cli data-section-id=\"breav2\" data-start=\"2833\" data-end=\"2850\"\u003eCSA Certified\u003c\/li\u003e\n\u003cli data-section-id=\"n6bouy\" data-start=\"2851\" data-end=\"2864\"\u003eCE Marked\u003c\/li\u003e\n\u003cli data-section-id=\"1nx0unc\" data-start=\"2865\" data-end=\"2882\"\u003eIEC Compliant\u003c\/li\u003e\n\u003cli data-section-id=\"esspgj\" data-start=\"2883\" data-end=\"2900\"\u003eNOM Certified\u003c\/li\u003e\n\u003cli data-section-id=\"7vo9c0\" data-start=\"2901\" data-end=\"2917\"\u003eCCC Approved\u003c\/li\u003e\n\u003cli data-section-id=\"605sas\" data-start=\"2918\" data-end=\"2934\"\u003eEAC Approved\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Square D","offers":[{"title":"NEW","offer_id":48528113205497,"sku":"BDA24100Y2","price":689.85,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/BDA260601-2-Pole-Circuit-Breaker_SquareD_1_1f291e5c-9389-4b94-96db-48f58b66b830.webp?v=1781419700","url":"https:\/\/mycircuitbreakers.com\/products\/square-d-bda2100y2-powerpact-b-circuit-breaker-2-pole-100a-thermal-magnetic-i-line-18ka-480vac","provider":"My Circuit Breakers","version":"1.0","type":"link"}