{"product_id":"square-d-bda260152-powerpact-b-circuit-breaker-2-pole-15a-thermal-magnetic-i-line-li-protection","title":"Square D BDA260152 PowerPact B Circuit Breaker – 2 Pole – 15A – Thermal Magnetic – I-Line – LI Protection","description":"\u003cp data-start=\"129\" data-end=\"510\"\u003eThe Square D BDA260152 is a PowerPact B-frame molded case circuit breaker engineered for dependable overcurrent protection in commercial and industrial electrical systems. Manufactured by Schneider Electric, this 2-pole breaker utilizes thermal-magnetic trip technology to provide Long-Time and Instantaneous (LI) protection against overloads and short circuits.\u003c\/p\u003e\n\u003cp data-start=\"512\" data-end=\"893\"\u003eRated at 15A, the BDA260152 is designed for installation in Square D I-Line panelboards and switchboards. It features a factory-configured AC phase connection and serves as the direct replacement for the discontinued FA26015AC circuit breaker. Its compact design, current-limiting performance, and HACR rating make it an excellent choice for modern power distribution applications.\u003c\/p\u003e\n\u003ch3 data-section-id=\"e5mrjc\" data-start=\"895\" data-end=\"915\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-start=\"917\" data-end=\"1189\"\u003e\n\u003cli data-section-id=\"1ii30bw\" data-start=\"917\" data-end=\"936\"\u003eBrand: Square D\u003c\/li\u003e\n\u003cli data-section-id=\"1mzzcj3\" data-start=\"937\" data-end=\"973\"\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n\u003cli data-section-id=\"1gl0r38\" data-start=\"974\" data-end=\"1009\"\u003eSeries: BDA (PowerPact B-Frame)\u003c\/li\u003e\n\u003cli data-section-id=\"13imsg3\" data-start=\"1010\" data-end=\"1036\"\u003ePart Number: BDA260152\u003c\/li\u003e\n\u003cli data-section-id=\"6rlgrk\" data-start=\"1037\" data-end=\"1081\"\u003eType: Molded Case Circuit Breaker (MCCB)\u003c\/li\u003e\n\u003cli data-section-id=\"zi4dnc\" data-start=\"1082\" data-end=\"1106\"\u003eAmperage Rating: 15A\u003c\/li\u003e\n\u003cli data-section-id=\"ksyb51\" data-start=\"1107\" data-end=\"1119\"\u003ePoles: 2\u003c\/li\u003e\n\u003cli data-section-id=\"11x0coz\" data-start=\"1120\" data-end=\"1138\"\u003ePhase: 1 Phase\u003c\/li\u003e\n\u003cli data-section-id=\"wh7dqa\" data-start=\"1139\" data-end=\"1165\"\u003eMounting Style: I-Line\u003c\/li\u003e\n\u003cli data-section-id=\"fl0tfn\" data-start=\"1166\" data-end=\"1189\"\u003eTerminal Type: Lugs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"oy7toc\" data-start=\"1191\" data-end=\"1215\"\u003eElectrical Ratings\u003c\/h3\u003e\n\u003cul data-start=\"1217\" data-end=\"1499\"\u003e\n\u003cli data-section-id=\"eyi3or\" data-start=\"1217\" data-end=\"1330\"\u003eVoltage Ratings:\n\u003cul data-start=\"1240\" data-end=\"1330\"\u003e\n\u003cli data-section-id=\"1uqein7\" data-start=\"1240\" data-end=\"1255\"\u003e208Y\/120VAC\u003c\/li\u003e\n\u003cli data-section-id=\"guirai\" data-start=\"1258\" data-end=\"1268\"\u003e240VAC\u003c\/li\u003e\n\u003cli data-section-id=\"evl76s\" data-start=\"1271\" data-end=\"1286\"\u003e480Y\/277VAC\u003c\/li\u003e\n\u003cli data-section-id=\"10ayli8\" data-start=\"1289\" data-end=\"1299\"\u003e480VAC\u003c\/li\u003e\n\u003cli data-section-id=\"64f68c\" data-start=\"1302\" data-end=\"1317\"\u003e600Y\/347VAC\u003c\/li\u003e\n\u003cli data-section-id=\"8locpa\" data-start=\"1320\" data-end=\"1330\"\u003e250VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1fh4qg0\" data-start=\"1332\" data-end=\"1499\"\u003eInterrupting Capacity (AIC):\n\u003cul data-start=\"1367\" data-end=\"1499\"\u003e\n\u003cli data-section-id=\"1apgsoe\" data-start=\"1367\" data-end=\"1389\"\u003e25kA @ 208Y\/120VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1hxk5s7\" data-start=\"1392\" data-end=\"1409\"\u003e25kA @ 240VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1466qyv\" data-start=\"1412\" data-end=\"1434\"\u003e18kA @ 480Y\/277VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1d6wag3\" data-start=\"1437\" data-end=\"1454\"\u003e18kA @ 480VAC\u003c\/li\u003e\n\u003cli data-section-id=\"9k9otf\" data-start=\"1457\" data-end=\"1479\"\u003e14kA @ 600Y\/347VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1gb0c1x\" data-start=\"1482\" data-end=\"1499\"\u003e10kA @ 250VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"5b7pht\" data-start=\"1501\" data-end=\"1531\"\u003eTrip Unit Specifications\u003c\/h3\u003e\n\u003cul data-start=\"1533\" data-end=\"1730\"\u003e\n\u003cli data-section-id=\"2puffi\" data-start=\"1533\" data-end=\"1570\"\u003eTrip Technology: Thermal Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"5ed487\" data-start=\"1571\" data-end=\"1597\"\u003eTrip Function Code: LI\u003c\/li\u003e\n\u003cli data-section-id=\"1fmsb4q\" data-start=\"1598\" data-end=\"1642\"\u003eTrip Functions: Long-Time, Instantaneous\u003c\/li\u003e\n\u003cli data-section-id=\"1crqvqj\" data-start=\"1643\" data-end=\"1696\"\u003eTrip Adjustability: Fixed Thermal, Fixed Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"agh1q3\" data-start=\"1697\" data-end=\"1730\"\u003eNon-Interchangeable Trip Unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"kxa3y3\" data-start=\"1732\" data-end=\"1751\"\u003eWire Capacity\u003c\/h3\u003e\n\u003cul data-start=\"1753\" data-end=\"1909\"\u003e\n\u003cli data-section-id=\"679nd3\" data-start=\"1753\" data-end=\"1791\"\u003eConductor Range: 14 AWG to 2\/0 AWG\u003c\/li\u003e\n\u003cli data-section-id=\"u6eem7\" data-start=\"1792\" data-end=\"1848\"\u003eCompatible Conductors: Copper (Cu) and Aluminum (Al)\u003c\/li\u003e\n\u003cli data-section-id=\"431q5m\" data-start=\"1849\" data-end=\"1879\"\u003eMaximum Wire Size: 2\/0 AWG\u003c\/li\u003e\n\u003cli data-section-id=\"1j655zw\" data-start=\"1880\" data-end=\"1909\"\u003eMinimum Wire Size: 14 AWG\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"337yl8\" data-start=\"1911\" data-end=\"1938\"\u003eConstruction Features\u003c\/h3\u003e\n\u003cul data-start=\"1940\" data-end=\"2128\"\u003e\n\u003cli data-section-id=\"k2kph2\" data-start=\"1940\" data-end=\"1954\"\u003eHACR Rated\u003c\/li\u003e\n\u003cli data-section-id=\"ixfkiz\" data-start=\"1955\" data-end=\"1982\"\u003eCurrent-Limiting Design\u003c\/li\u003e\n\u003cli data-section-id=\"9xscgi\" data-start=\"1983\" data-end=\"2007\"\u003eReverse Feed Capable\u003c\/li\u003e\n\u003cli data-section-id=\"1n6r72e\" data-start=\"2008\" data-end=\"2050\"\u003eFactory-Configured AC Phase Connection\u003c\/li\u003e\n\u003cli data-section-id=\"exwh6h\" data-start=\"2051\" data-end=\"2093\"\u003eCompact PowerPact B-Frame Construction\u003c\/li\u003e\n\u003cli data-section-id=\"kty45k\" data-start=\"2094\" data-end=\"2128\"\u003eI-Line Plug-On Mounting System\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"qtkp3j\" data-start=\"2130\" data-end=\"2153\"\u003eAvailable Options\u003c\/h3\u003e\n\u003cul data-start=\"2155\" data-end=\"2273\"\u003e\n\u003cli data-section-id=\"1is1mo3\" data-start=\"2155\" data-end=\"2169\"\u003eShunt Trip\u003c\/li\u003e\n\u003cli data-section-id=\"i91omo\" data-start=\"2170\" data-end=\"2190\"\u003eAuxiliary Switch\u003c\/li\u003e\n\u003cli data-section-id=\"1jdu86j\" data-start=\"2191\" data-end=\"2215\"\u003eUndervoltage Release\u003c\/li\u003e\n\u003cli data-section-id=\"188ml0p\" data-start=\"2216\" data-end=\"2232\"\u003eAlarm Switch\u003c\/li\u003e\n\u003cli data-section-id=\"1c1t4i7\" data-start=\"2233\" data-end=\"2255\"\u003ePadlock Attachment\u003c\/li\u003e\n\u003cli data-section-id=\"riy5i9\" data-start=\"2256\" data-end=\"2273\"\u003eRotary Handle\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"q67t74\" data-start=\"2275\" data-end=\"2309\"\u003eEnvironmental Specifications\u003c\/h3\u003e\n\u003cul data-start=\"2311\" data-end=\"2351\"\u003e\n\u003cli data-section-id=\"1at0y7p\" data-start=\"2311\" data-end=\"2351\"\u003eOperating Temperature: -25°C to 70°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"17tovxr\" data-start=\"2353\" data-end=\"2371\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"2373\" data-end=\"2601\"\u003e\n\u003cli data-section-id=\"1e2izfc\" data-start=\"2373\" data-end=\"2404\"\u003eSquare D I-Line Panelboards\u003c\/li\u003e\n\u003cli data-section-id=\"1tbswuu\" data-start=\"2405\" data-end=\"2430\"\u003eSquare D Switchboards\u003c\/li\u003e\n\u003cli data-section-id=\"ephhtz\" data-start=\"2431\" data-end=\"2472\"\u003eCommercial Power Distribution Systems\u003c\/li\u003e\n\u003cli data-section-id=\"li133i\" data-start=\"2473\" data-end=\"2512\"\u003eIndustrial Electrical Installations\u003c\/li\u003e\n\u003cli data-section-id=\"1e3kvy5\" data-start=\"2513\" data-end=\"2542\"\u003eHVAC Equipment Protection\u003c\/li\u003e\n\u003cli data-section-id=\"ujupcc\" data-start=\"2543\" data-end=\"2572\"\u003eBranch Circuit Protection\u003c\/li\u003e\n\u003cli data-section-id=\"2hrv3f\" data-start=\"2573\" data-end=\"2601\"\u003eOEM Electrical Equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"174ui70\" data-start=\"2603\" data-end=\"2630\"\u003eStandards \u0026amp; Approvals\u003c\/h3\u003e\n\u003cul data-start=\"2632\" data-end=\"2692\"\u003e\n\u003cli data-section-id=\"6d8czo\" data-start=\"2632\" data-end=\"2642\"\u003eUL 489\u003c\/li\u003e\n\u003cli data-section-id=\"12xbscc\" data-start=\"2643\" data-end=\"2662\"\u003eCSA C22.2 No. 5\u003c\/li\u003e\n\u003cli data-section-id=\"1pw3smc\" data-start=\"2663\" data-end=\"2678\"\u003eIEC 60947-2\u003c\/li\u003e\n\u003cli data-section-id=\"11cuwal\" data-start=\"2679\" data-end=\"2692\"\u003eNEMA AB 1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Square D","offers":[{"title":"NEW","offer_id":48528119693561,"sku":"BDA260152","price":583.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/BDA260601-2-Pole-Circuit-Breaker_SquareD_1_915dec0c-f4cb-461f-905e-1a4d2188b8f1.webp?v=1781419876","url":"https:\/\/mycircuitbreakers.com\/products\/square-d-bda260152-powerpact-b-circuit-breaker-2-pole-15a-thermal-magnetic-i-line-li-protection","provider":"My Circuit Breakers","version":"1.0","type":"link"}