{"product_id":"square-d-bda260301-powerpact-b-circuit-breaker-2-pole-30a-thermal-magnetic-i-line-ab-phase-connection","title":"Square D BDA260301 PowerPact B Circuit Breaker – 2 Pole – 30A – Thermal Magnetic – I-Line – AB Phase Connection","description":"\u003cp data-start=\"135\" data-end=\"570\"\u003eThe Square D BDA260301 is a PowerPact B-frame molded case circuit breaker designed to provide dependable overload and short-circuit protection in commercial and industrial electrical distribution systems. Manufactured by Schneider Electric, this 30A, 2-pole breaker utilizes thermal-magnetic trip technology to deliver reliable Long-Time and Instantaneous (LI) protection for branch circuits and connected equipment.\u003c\/p\u003e\n\u003cp data-start=\"572\" data-end=\"1017\"\u003eDesigned specifically for Square D I-Line panelboards and switchboards, the BDA260301 features an integrated I-Line plug-on connection and a factory-configured AB phase arrangement. It serves as a direct replacement for the legacy FA26030AB breaker, offering enhanced performance and simplified maintenance. The built-in Visi-Trip visual indicator allows rapid identification of tripped conditions, reducing downtime and troubleshooting efforts.\u003c\/p\u003e\n\u003ch3 data-section-id=\"e5mrjc\" data-start=\"1019\" data-end=\"1039\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-start=\"1041\" data-end=\"1313\"\u003e\n\u003cli data-section-id=\"1ii30bw\" data-start=\"1041\" data-end=\"1060\"\u003eBrand: Square D\u003c\/li\u003e\n\u003cli data-section-id=\"1mzzcj3\" data-start=\"1061\" data-end=\"1097\"\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n\u003cli data-section-id=\"1gl0r38\" data-start=\"1098\" data-end=\"1133\"\u003eSeries: BDA (PowerPact B-Frame)\u003c\/li\u003e\n\u003cli data-section-id=\"13k5gdj\" data-start=\"1134\" data-end=\"1160\"\u003ePart Number: BDA260301\u003c\/li\u003e\n\u003cli data-section-id=\"6rlgrk\" data-start=\"1161\" data-end=\"1205\"\u003eType: Molded Case Circuit Breaker (MCCB)\u003c\/li\u003e\n\u003cli data-section-id=\"zjok8v\" data-start=\"1206\" data-end=\"1230\"\u003eAmperage Rating: 30A\u003c\/li\u003e\n\u003cli data-section-id=\"ksyb51\" data-start=\"1231\" data-end=\"1243\"\u003ePoles: 2\u003c\/li\u003e\n\u003cli data-section-id=\"11x0coz\" data-start=\"1244\" data-end=\"1262\"\u003ePhase: 1 Phase\u003c\/li\u003e\n\u003cli data-section-id=\"wh7dqa\" data-start=\"1263\" data-end=\"1289\"\u003eMounting Style: I-Line\u003c\/li\u003e\n\u003cli data-section-id=\"fl0tfn\" data-start=\"1290\" data-end=\"1313\"\u003eTerminal Type: Lugs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"oy7toc\" data-start=\"1315\" data-end=\"1339\"\u003eElectrical Ratings\u003c\/h3\u003e\n\u003cul data-start=\"1341\" data-end=\"1623\"\u003e\n\u003cli data-section-id=\"eyi3or\" data-start=\"1341\" data-end=\"1454\"\u003eVoltage Ratings:\n\u003cul data-start=\"1364\" data-end=\"1454\"\u003e\n\u003cli data-section-id=\"1uqein7\" data-start=\"1364\" data-end=\"1379\"\u003e208Y\/120VAC\u003c\/li\u003e\n\u003cli data-section-id=\"guirai\" data-start=\"1382\" data-end=\"1392\"\u003e240VAC\u003c\/li\u003e\n\u003cli data-section-id=\"evl76s\" data-start=\"1395\" data-end=\"1410\"\u003e480Y\/277VAC\u003c\/li\u003e\n\u003cli data-section-id=\"10ayli8\" data-start=\"1413\" data-end=\"1423\"\u003e480VAC\u003c\/li\u003e\n\u003cli data-section-id=\"64f68c\" data-start=\"1426\" data-end=\"1441\"\u003e600Y\/347VAC\u003c\/li\u003e\n\u003cli data-section-id=\"8locpa\" data-start=\"1444\" data-end=\"1454\"\u003e250VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1fh4qg0\" data-start=\"1456\" data-end=\"1623\"\u003eInterrupting Capacity (AIC):\n\u003cul data-start=\"1491\" data-end=\"1623\"\u003e\n\u003cli data-section-id=\"1apgsoe\" data-start=\"1491\" data-end=\"1513\"\u003e25kA @ 208Y\/120VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1hxk5s7\" data-start=\"1516\" data-end=\"1533\"\u003e25kA @ 240VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1466qyv\" data-start=\"1536\" data-end=\"1558\"\u003e18kA @ 480Y\/277VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1d6wag3\" data-start=\"1561\" data-end=\"1578\"\u003e18kA @ 480VAC\u003c\/li\u003e\n\u003cli data-section-id=\"9k9otf\" data-start=\"1581\" data-end=\"1603\"\u003e14kA @ 600Y\/347VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1gb0c1x\" data-start=\"1606\" data-end=\"1623\"\u003e10kA @ 250VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"5b7pht\" data-start=\"1625\" data-end=\"1655\"\u003eTrip Unit Specifications\u003c\/h3\u003e\n\u003cul data-start=\"1657\" data-end=\"1820\"\u003e\n\u003cli data-section-id=\"2puffi\" data-start=\"1657\" data-end=\"1694\"\u003eTrip Technology: Thermal Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"5ed487\" data-start=\"1695\" data-end=\"1721\"\u003eTrip Function Code: LI\u003c\/li\u003e\n\u003cli data-section-id=\"1fmsb4q\" data-start=\"1722\" data-end=\"1766\"\u003eTrip Functions: Long-Time, Instantaneous\u003c\/li\u003e\n\u003cli data-section-id=\"1crqvqj\" data-start=\"1767\" data-end=\"1820\"\u003eTrip Adjustability: Fixed Thermal, Fixed Magnetic\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"kxa3y3\" data-start=\"1822\" data-end=\"1841\"\u003eWire Capacity\u003c\/h3\u003e\n\u003cul data-start=\"1843\" data-end=\"1999\"\u003e\n\u003cli data-section-id=\"679nd3\" data-start=\"1843\" data-end=\"1881\"\u003eConductor Range: 14 AWG to 2\/0 AWG\u003c\/li\u003e\n\u003cli data-section-id=\"u6eem7\" data-start=\"1882\" data-end=\"1938\"\u003eCompatible Conductors: Copper (Cu) and Aluminum (Al)\u003c\/li\u003e\n\u003cli data-section-id=\"431q5m\" data-start=\"1939\" data-end=\"1969\"\u003eMaximum Wire Size: 2\/0 AWG\u003c\/li\u003e\n\u003cli data-section-id=\"1j655zw\" data-start=\"1970\" data-end=\"1999\"\u003eMinimum Wire Size: 14 AWG\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"337yl8\" data-start=\"2001\" data-end=\"2028\"\u003eConstruction Features\u003c\/h3\u003e\n\u003cul data-start=\"2030\" data-end=\"2228\"\u003e\n\u003cli data-section-id=\"k2kph2\" data-start=\"2030\" data-end=\"2044\"\u003eHACR Rated\u003c\/li\u003e\n\u003cli data-section-id=\"ixfkiz\" data-start=\"2045\" data-end=\"2072\"\u003eCurrent-Limiting Design\u003c\/li\u003e\n\u003cli data-section-id=\"1vxwel1\" data-start=\"2073\" data-end=\"2108\"\u003eVisi-Trip Visual Trip Indicator\u003c\/li\u003e\n\u003cli data-section-id=\"utm99j\" data-start=\"2109\" data-end=\"2151\"\u003eFactory-Configured AB Phase Connection\u003c\/li\u003e\n\u003cli data-section-id=\"1jzu7aj\" data-start=\"2152\" data-end=\"2185\"\u003eIntegrated I-Line Plug-On Jaw\u003c\/li\u003e\n\u003cli data-section-id=\"exwh6h\" data-start=\"2186\" data-end=\"2228\"\u003eCompact PowerPact B-Frame Construction\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"qtkp3j\" data-start=\"2230\" data-end=\"2253\"\u003eAvailable Options\u003c\/h3\u003e\n\u003cul data-start=\"2255\" data-end=\"2392\"\u003e\n\u003cli data-section-id=\"1is1mo3\" data-start=\"2255\" data-end=\"2269\"\u003eShunt Trip\u003c\/li\u003e\n\u003cli data-section-id=\"i91omo\" data-start=\"2270\" data-end=\"2290\"\u003eAuxiliary Switch\u003c\/li\u003e\n\u003cli data-section-id=\"1jdu86j\" data-start=\"2291\" data-end=\"2315\"\u003eUndervoltage Release\u003c\/li\u003e\n\u003cli data-section-id=\"188ml0p\" data-start=\"2316\" data-end=\"2332\"\u003eAlarm Switch\u003c\/li\u003e\n\u003cli data-section-id=\"1c1t4i7\" data-start=\"2333\" data-end=\"2355\"\u003ePadlock Attachment\u003c\/li\u003e\n\u003cli data-section-id=\"riy5i9\" data-start=\"2356\" data-end=\"2373\"\u003eRotary Handle\u003c\/li\u003e\n\u003cli data-section-id=\"1aqwu83\" data-start=\"2374\" data-end=\"2392\"\u003eMotor Operator\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"q67t74\" data-start=\"2394\" data-end=\"2428\"\u003eEnvironmental Specifications\u003c\/h3\u003e\n\u003cul data-start=\"2430\" data-end=\"2470\"\u003e\n\u003cli data-section-id=\"1at0y7p\" data-start=\"2430\" data-end=\"2470\"\u003eOperating Temperature: -25°C to 70°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"17tovxr\" data-start=\"2472\" data-end=\"2490\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"2492\" data-end=\"2727\"\u003e\n\u003cli data-section-id=\"1e2izfc\" data-start=\"2492\" data-end=\"2523\"\u003eSquare D I-Line Panelboards\u003c\/li\u003e\n\u003cli data-section-id=\"g0hcn0\" data-start=\"2524\" data-end=\"2556\"\u003eSquare D I-Line Switchboards\u003c\/li\u003e\n\u003cli data-section-id=\"ephhtz\" data-start=\"2557\" data-end=\"2598\"\u003eCommercial Power Distribution Systems\u003c\/li\u003e\n\u003cli data-section-id=\"li133i\" data-start=\"2599\" data-end=\"2638\"\u003eIndustrial Electrical Installations\u003c\/li\u003e\n\u003cli data-section-id=\"1e3kvy5\" data-start=\"2639\" data-end=\"2668\"\u003eHVAC Equipment Protection\u003c\/li\u003e\n\u003cli data-section-id=\"ujupcc\" data-start=\"2669\" data-end=\"2698\"\u003eBranch Circuit Protection\u003c\/li\u003e\n\u003cli data-section-id=\"2hrv3f\" data-start=\"2699\" data-end=\"2727\"\u003eOEM Electrical Equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"174ui70\" data-start=\"2729\" data-end=\"2756\"\u003eStandards \u0026amp; Approvals\u003c\/h3\u003e\n\u003cul data-start=\"2758\" data-end=\"2821\"\u003e\n\u003cli data-section-id=\"6d8czo\" data-start=\"2758\" data-end=\"2768\"\u003eUL 489\u003c\/li\u003e\n\u003cli data-section-id=\"12xbscc\" data-start=\"2769\" data-end=\"2788\"\u003eCSA C22.2 No. 5\u003c\/li\u003e\n\u003cli data-section-id=\"1a1r7gg\" data-start=\"2789\" data-end=\"2807\"\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003cli data-section-id=\"11cuwal\" data-start=\"2808\" data-end=\"2821\"\u003eNEMA AB 1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2823\" data-end=\"2839\"\u003e\u003cstrong data-start=\"2823\" data-end=\"2837\"\u003eApprovals:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2841\" data-end=\"2956\"\u003e\n\u003cli data-section-id=\"1w9xzw2\" data-start=\"2841\" data-end=\"2854\"\u003eUL Listed\u003c\/li\u003e\n\u003cli data-section-id=\"breav2\" data-start=\"2855\" data-end=\"2872\"\u003eCSA Certified\u003c\/li\u003e\n\u003cli data-section-id=\"n6bouy\" data-start=\"2873\" data-end=\"2886\"\u003eCE Marked\u003c\/li\u003e\n\u003cli data-section-id=\"1nx0unc\" data-start=\"2887\" data-end=\"2904\"\u003eIEC Compliant\u003c\/li\u003e\n\u003cli data-section-id=\"esspgj\" data-start=\"2905\" data-end=\"2922\"\u003eNOM Certified\u003c\/li\u003e\n\u003cli data-section-id=\"7vo9c0\" data-start=\"2923\" data-end=\"2939\"\u003eCCC Approved\u003c\/li\u003e\n\u003cli data-section-id=\"605sas\" data-start=\"2940\" data-end=\"2956\"\u003eEAC Approved\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Square D","offers":[{"title":"NEW","offer_id":48528134013177,"sku":"BDA260301","price":583.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/BDA260601-2-Pole-Circuit-Breaker_SquareD_1_4418a1bb-0e0a-4422-89c3-c0d38a608600.webp?v=1781420299","url":"https:\/\/mycircuitbreakers.com\/products\/square-d-bda260301-powerpact-b-circuit-breaker-2-pole-30a-thermal-magnetic-i-line-ab-phase-connection","provider":"My Circuit Breakers","version":"1.0","type":"link"}