{"product_id":"square-d-bda260902-powerpact-b-circuit-breaker-2-pole-90a-thermal-magnetic-i-line-ac-phase-connection","title":"Square D BDA260902 PowerPact B Circuit Breaker – 2 Pole – 90A – Thermal Magnetic – I-Line – AC Phase Connection","description":"\u003cp data-start=\"135\" data-end=\"550\"\u003eThe Square D BDA260902 is a PowerPact B-frame molded case circuit breaker designed for reliable overcurrent protection in industrial and commercial power distribution systems. Manufactured by Schneider Electric, this 2-pole, 90A breaker provides fixed thermal and magnetic (LI) protection for branch circuits and feeders, ensuring dependable operation under overload and short-circuit conditions.\u003c\/p\u003e\n\u003cp data-start=\"552\" data-end=\"972\"\u003eDesigned for Square D I-Line panelboards and switchboards, the BDA260902 features a plug-on I-Line mounting system for fast installation and straightforward replacement of legacy FA26090AC breakers. Its AC phase configuration and load-side lug terminals support secure wiring and compatibility with existing systems. With a robust B-frame construction, it delivers efficient performance in compact electrical enclosures.\u003c\/p\u003e\n\u003ch3 data-section-id=\"e5mrjc\" data-start=\"974\" data-end=\"994\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-start=\"996\" data-end=\"1279\"\u003e\n\u003cli data-section-id=\"1ii30bw\" data-start=\"996\" data-end=\"1015\"\u003eBrand: Square D\u003c\/li\u003e\n\u003cli data-section-id=\"f8032d\" data-start=\"1016\" data-end=\"1063\"\u003eManufacturer: Schneider Electric \/ Square D\u003c\/li\u003e\n\u003cli data-section-id=\"1gl0r38\" data-start=\"1064\" data-end=\"1099\"\u003eSeries: BDA (PowerPact B-Frame)\u003c\/li\u003e\n\u003cli data-section-id=\"13odxym\" data-start=\"1100\" data-end=\"1126\"\u003ePart Number: BDA260902\u003c\/li\u003e\n\u003cli data-section-id=\"6rlgrk\" data-start=\"1127\" data-end=\"1171\"\u003eType: Molded Case Circuit Breaker (MCCB)\u003c\/li\u003e\n\u003cli data-section-id=\"zcmdmd\" data-start=\"1172\" data-end=\"1196\"\u003eAmperage Rating: 90A\u003c\/li\u003e\n\u003cli data-section-id=\"ksyb51\" data-start=\"1197\" data-end=\"1209\"\u003ePoles: 2\u003c\/li\u003e\n\u003cli data-section-id=\"11x0coz\" data-start=\"1210\" data-end=\"1228\"\u003ePhase: 1 Phase\u003c\/li\u003e\n\u003cli data-section-id=\"wh7dqa\" data-start=\"1229\" data-end=\"1255\"\u003eMounting Style: I-Line\u003c\/li\u003e\n\u003cli data-section-id=\"fl0tfn\" data-start=\"1256\" data-end=\"1279\"\u003eTerminal Type: Lugs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"oy7toc\" data-start=\"1281\" data-end=\"1305\"\u003eElectrical Ratings\u003c\/h3\u003e\n\u003cul data-start=\"1307\" data-end=\"1589\"\u003e\n\u003cli data-section-id=\"eyi3or\" data-start=\"1307\" data-end=\"1420\"\u003eVoltage Ratings:\n\u003cul data-start=\"1330\" data-end=\"1420\"\u003e\n\u003cli data-section-id=\"1uqein7\" data-start=\"1330\" data-end=\"1345\"\u003e208Y\/120VAC\u003c\/li\u003e\n\u003cli data-section-id=\"guirai\" data-start=\"1348\" data-end=\"1358\"\u003e240VAC\u003c\/li\u003e\n\u003cli data-section-id=\"evl76s\" data-start=\"1361\" data-end=\"1376\"\u003e480Y\/277VAC\u003c\/li\u003e\n\u003cli data-section-id=\"10ayli8\" data-start=\"1379\" data-end=\"1389\"\u003e480VAC\u003c\/li\u003e\n\u003cli data-section-id=\"64f68c\" data-start=\"1392\" data-end=\"1407\"\u003e600Y\/347VAC\u003c\/li\u003e\n\u003cli data-section-id=\"8locpa\" data-start=\"1410\" data-end=\"1420\"\u003e250VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1fh4qg0\" data-start=\"1422\" data-end=\"1589\"\u003eInterrupting Capacity (AIC):\n\u003cul data-start=\"1457\" data-end=\"1589\"\u003e\n\u003cli data-section-id=\"1apgsoe\" data-start=\"1457\" data-end=\"1479\"\u003e25kA @ 208Y\/120VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1hxk5s7\" data-start=\"1482\" data-end=\"1499\"\u003e25kA @ 240VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1466qyv\" data-start=\"1502\" data-end=\"1524\"\u003e18kA @ 480Y\/277VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1d6wag3\" data-start=\"1527\" data-end=\"1544\"\u003e18kA @ 480VAC\u003c\/li\u003e\n\u003cli data-section-id=\"9k9otf\" data-start=\"1547\" data-end=\"1569\"\u003e14kA @ 600Y\/347VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1gb0c1x\" data-start=\"1572\" data-end=\"1589\"\u003e10kA @ 250VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"5b7pht\" data-start=\"1591\" data-end=\"1621\"\u003eTrip Unit Specifications\u003c\/h3\u003e\n\u003cul data-start=\"1623\" data-end=\"1786\"\u003e\n\u003cli data-section-id=\"2puffi\" data-start=\"1623\" data-end=\"1660\"\u003eTrip Technology: Thermal Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"5ed487\" data-start=\"1661\" data-end=\"1687\"\u003eTrip Function Code: LI\u003c\/li\u003e\n\u003cli data-section-id=\"1fmsb4q\" data-start=\"1688\" data-end=\"1732\"\u003eTrip Functions: Long-Time, Instantaneous\u003c\/li\u003e\n\u003cli data-section-id=\"1crqvqj\" data-start=\"1733\" data-end=\"1786\"\u003eTrip Adjustability: Fixed Thermal, Fixed Magnetic\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"kxa3y3\" data-start=\"1788\" data-end=\"1807\"\u003eWire Capacity\u003c\/h3\u003e\n\u003cul data-start=\"1809\" data-end=\"1965\"\u003e\n\u003cli data-section-id=\"679nd3\" data-start=\"1809\" data-end=\"1847\"\u003eConductor Range: 14 AWG to 2\/0 AWG\u003c\/li\u003e\n\u003cli data-section-id=\"u6eem7\" data-start=\"1848\" data-end=\"1904\"\u003eCompatible Conductors: Copper (Cu) and Aluminum (Al)\u003c\/li\u003e\n\u003cli data-section-id=\"431q5m\" data-start=\"1905\" data-end=\"1935\"\u003eMaximum Wire Size: 2\/0 AWG\u003c\/li\u003e\n\u003cli data-section-id=\"1j655zw\" data-start=\"1936\" data-end=\"1965\"\u003eMinimum Wire Size: 14 AWG\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"337yl8\" data-start=\"1967\" data-end=\"1994\"\u003eConstruction Features\u003c\/h3\u003e\n\u003cul data-start=\"1996\" data-end=\"2207\"\u003e\n\u003cli data-section-id=\"k2kph2\" data-start=\"1996\" data-end=\"2010\"\u003eHACR Rated\u003c\/li\u003e\n\u003cli data-section-id=\"486s2e\" data-start=\"2011\" data-end=\"2047\"\u003eCompact PowerPact B-Frame Design\u003c\/li\u003e\n\u003cli data-section-id=\"irrf41\" data-start=\"2048\" data-end=\"2080\"\u003eCurrent-Limiting Performance\u003c\/li\u003e\n\u003cli data-section-id=\"kty45k\" data-start=\"2081\" data-end=\"2115\"\u003eI-Line Plug-On Mounting System\u003c\/li\u003e\n\u003cli data-section-id=\"fj4fki\" data-start=\"2116\" data-end=\"2145\"\u003eLoad-Side Lug Termination\u003c\/li\u003e\n\u003cli data-section-id=\"17mfj6b\" data-start=\"2146\" data-end=\"2169\"\u003eAC Phase Connection\u003c\/li\u003e\n\u003cli data-section-id=\"searc5\" data-start=\"2170\" data-end=\"2207\"\u003eFixed Thermal-Magnetic Protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"qtkp3j\" data-start=\"2209\" data-end=\"2232\"\u003eAvailable Options\u003c\/h3\u003e\n\u003cul data-start=\"2234\" data-end=\"2371\"\u003e\n\u003cli data-section-id=\"1is1mo3\" data-start=\"2234\" data-end=\"2248\"\u003eShunt Trip\u003c\/li\u003e\n\u003cli data-section-id=\"i91omo\" data-start=\"2249\" data-end=\"2269\"\u003eAuxiliary Switch\u003c\/li\u003e\n\u003cli data-section-id=\"1jdu86j\" data-start=\"2270\" data-end=\"2294\"\u003eUndervoltage Release\u003c\/li\u003e\n\u003cli data-section-id=\"188ml0p\" data-start=\"2295\" data-end=\"2311\"\u003eAlarm Switch\u003c\/li\u003e\n\u003cli data-section-id=\"1c1t4i7\" data-start=\"2312\" data-end=\"2334\"\u003ePadlock Attachment\u003c\/li\u003e\n\u003cli data-section-id=\"riy5i9\" data-start=\"2335\" data-end=\"2352\"\u003eRotary Handle\u003c\/li\u003e\n\u003cli data-section-id=\"1aqwu83\" data-start=\"2353\" data-end=\"2371\"\u003eMotor Operator\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"pgfqo0\" data-start=\"2373\" data-end=\"2390\"\u003eAccessories\u003c\/h3\u003e\n\u003cul data-start=\"2392\" data-end=\"2409\"\u003e\n\u003cli data-section-id=\"ynemca\" data-start=\"2392\" data-end=\"2409\"\u003eNone Included\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"q67t74\" data-start=\"2411\" data-end=\"2445\"\u003eEnvironmental Specifications\u003c\/h3\u003e\n\u003cul data-start=\"2447\" data-end=\"2487\"\u003e\n\u003cli data-section-id=\"1at0y7p\" data-start=\"2447\" data-end=\"2487\"\u003eOperating Temperature: -25°C to 70°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"17tovxr\" data-start=\"2489\" data-end=\"2507\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"2509\" data-end=\"2735\"\u003e\n\u003cli data-section-id=\"1e2izfc\" data-start=\"2509\" data-end=\"2540\"\u003eSquare D I-Line Panelboards\u003c\/li\u003e\n\u003cli data-section-id=\"g0hcn0\" data-start=\"2541\" data-end=\"2573\"\u003eSquare D I-Line Switchboards\u003c\/li\u003e\n\u003cli data-section-id=\"kyb6ty\" data-start=\"2574\" data-end=\"2620\"\u003eCommercial Electrical Distribution Systems\u003c\/li\u003e\n\u003cli data-section-id=\"1hm109y\" data-start=\"2621\" data-end=\"2649\"\u003eIndustrial Power Systems\u003c\/li\u003e\n\u003cli data-section-id=\"ujupcc\" data-start=\"2650\" data-end=\"2679\"\u003eBranch Circuit Protection\u003c\/li\u003e\n\u003cli data-section-id=\"1e3kvy5\" data-start=\"2680\" data-end=\"2709\"\u003eHVAC Equipment Protection\u003c\/li\u003e\n\u003cli data-section-id=\"cj8adg\" data-start=\"2710\" data-end=\"2735\"\u003eOEM Electrical Panels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"174ui70\" data-start=\"2737\" data-end=\"2764\"\u003eStandards \u0026amp; Approvals\u003c\/h3\u003e\n\u003cul data-start=\"2766\" data-end=\"2858\"\u003e\n\u003cli data-section-id=\"6d8czo\" data-start=\"2766\" data-end=\"2776\"\u003eUL 489\u003c\/li\u003e\n\u003cli data-section-id=\"12xbscc\" data-start=\"2777\" data-end=\"2796\"\u003eCSA C22.2 No. 5\u003c\/li\u003e\n\u003cli data-section-id=\"1a1r7gg\" data-start=\"2797\" data-end=\"2815\"\u003eEN\/IEC 60947-2\u003c\/li\u003e\n\u003cli data-section-id=\"11cuwal\" data-start=\"2816\" data-end=\"2829\"\u003eNEMA AB 1\u003c\/li\u003e\n\u003cli data-section-id=\"1a71x6w\" data-start=\"2830\" data-end=\"2844\"\u003eGB 14048.2\u003c\/li\u003e\n\u003cli data-section-id=\"ewodza\" data-start=\"2845\" data-end=\"2858\"\u003eNMX J-266\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2860\" data-end=\"2876\"\u003e\u003cstrong data-start=\"2860\" data-end=\"2874\"\u003eApprovals:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2877\" data-end=\"2992\"\u003e\n\u003cli data-section-id=\"1w9xzw2\" data-start=\"2877\" data-end=\"2890\"\u003eUL Listed\u003c\/li\u003e\n\u003cli data-section-id=\"breav2\" data-start=\"2891\" data-end=\"2908\"\u003eCSA Certified\u003c\/li\u003e\n\u003cli data-section-id=\"n6bouy\" data-start=\"2909\" data-end=\"2922\"\u003eCE Marked\u003c\/li\u003e\n\u003cli data-section-id=\"1nx0unc\" data-start=\"2923\" data-end=\"2940\"\u003eIEC Compliant\u003c\/li\u003e\n\u003cli data-section-id=\"7vo9c0\" data-start=\"2941\" data-end=\"2957\"\u003eCCC Approved\u003c\/li\u003e\n\u003cli data-section-id=\"605sas\" data-start=\"2958\" data-end=\"2974\"\u003eEAC Approved\u003c\/li\u003e\n\u003cli data-section-id=\"esspgj\" data-start=\"2975\" data-end=\"2992\"\u003eNOM Certified\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Square D","offers":[{"title":"NEW","offer_id":48528162816249,"sku":"BDA260902","price":642.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/BDA260601-2-Pole-Circuit-Breaker_SquareD_1_136e9aa9-981a-4ac4-b80e-bb2eb93becaa.webp?v=1781421388","url":"https:\/\/mycircuitbreakers.com\/products\/square-d-bda260902-powerpact-b-circuit-breaker-2-pole-90a-thermal-magnetic-i-line-ac-phase-connection","provider":"My Circuit Breakers","version":"1.0","type":"link"}