{"product_id":"square-d-bda261001-powerpact-b-circuit-breaker-2-pole-100a-thermal-magnetic-i-line-600v-class","title":"Square D BDA261001 PowerPact B Circuit Breaker – 2 Pole – 100A – Thermal Magnetic – I-Line – 600V Class","description":"\u003cp data-start=\"127\" data-end=\"525\"\u003eThe Square D BDA261001 is a PowerPact B-frame molded case circuit breaker manufactured by Schneider Electric, designed for reliable overcurrent protection in commercial and industrial electrical distribution systems. This 2-pole, 100A breaker uses thermal-magnetic trip technology to provide Long-Time and Instantaneous (LI) protection against overloads and short-circuit faults.\u003c\/p\u003e\n\u003cp data-start=\"527\" data-end=\"856\"\u003eEngineered for Square D I-Line panelboards and switchboards, the BDA261001 features a plug-on I-Line mounting system for fast installation and replacement. It is commonly used as a direct replacement for legacy B-frame breakers in distribution equipment and supports both copper and aluminum conductors for flexible field wiring.\u003c\/p\u003e\n\u003ch3 data-section-id=\"e5mrjc\" data-start=\"858\" data-end=\"878\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-start=\"880\" data-end=\"1245\"\u003e\n\u003cli data-section-id=\"1ii30bw\" data-start=\"880\" data-end=\"899\"\u003eBrand: Square D\u003c\/li\u003e\n\u003cli data-section-id=\"f8032d\" data-start=\"900\" data-end=\"947\"\u003eManufacturer: Schneider Electric \/ Square D\u003c\/li\u003e\n\u003cli data-section-id=\"10l77vt\" data-start=\"948\" data-end=\"983\"\u003eSeries: PowerPact B (BDA Frame)\u003c\/li\u003e\n\u003cli data-section-id=\"11oa7gl\" data-start=\"984\" data-end=\"1010\"\u003ePart Number: BDA261001\u003c\/li\u003e\n\u003cli data-section-id=\"6rlgrk\" data-start=\"1011\" data-end=\"1055\"\u003eType: Molded Case Circuit Breaker (MCCB)\u003c\/li\u003e\n\u003cli data-section-id=\"z6pr2l\" data-start=\"1056\" data-end=\"1081\"\u003eAmperage Rating: 100A\u003c\/li\u003e\n\u003cli data-section-id=\"ksyb51\" data-start=\"1082\" data-end=\"1094\"\u003ePoles: 2\u003c\/li\u003e\n\u003cli data-section-id=\"11x0coz\" data-start=\"1095\" data-end=\"1113\"\u003ePhase: 1 Phase\u003c\/li\u003e\n\u003cli data-section-id=\"a6fqs4\" data-start=\"1114\" data-end=\"1172\"\u003eVoltage Rating: 600V Class (up to 600Y\/347VAC systems)\u003c\/li\u003e\n\u003cli data-section-id=\"qq8k06\" data-start=\"1173\" data-end=\"1207\"\u003eMounting Style: I-Line Plug-In\u003c\/li\u003e\n\u003cli data-section-id=\"11bg4ww\" data-start=\"1208\" data-end=\"1245\"\u003eTerminal Type: Line and Load Lugs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"oy7toc\" data-start=\"1247\" data-end=\"1271\"\u003eElectrical Ratings\u003c\/h3\u003e\n\u003cul data-start=\"1273\" data-end=\"1523\"\u003e\n\u003cli data-section-id=\"15a2mx5\" data-start=\"1273\" data-end=\"1390\"\u003eInterrupting Capacity (AIC):\n\u003cul data-start=\"1308\" data-end=\"1390\"\u003e\n\u003cli data-section-id=\"1hxk5s7\" data-start=\"1308\" data-end=\"1325\"\u003e25kA @ 240VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1d6wag3\" data-start=\"1328\" data-end=\"1345\"\u003e18kA @ 480VAC\u003c\/li\u003e\n\u003cli data-section-id=\"9k9otf\" data-start=\"1348\" data-end=\"1370\"\u003e14kA @ 600Y\/347VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1gb0c1x\" data-start=\"1373\" data-end=\"1390\"\u003e10kA @ 250VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"g2iaqk\" data-start=\"1392\" data-end=\"1429\"\u003eProtection Type: Thermal Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"19rdzo9\" data-start=\"1430\" data-end=\"1482\"\u003eTrip Functions: Long-Time and Instantaneous (LI)\u003c\/li\u003e\n\u003cli data-section-id=\"jbg54q\" data-start=\"1483\" data-end=\"1523\"\u003eContinuous Current Rating: 80% Rated\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1t5od0y\" data-start=\"1525\" data-end=\"1549\"\u003eConnection Details\u003c\/h3\u003e\n\u003cul data-start=\"1551\" data-end=\"1699\"\u003e\n\u003cli data-section-id=\"673ccm\" data-start=\"1551\" data-end=\"1585\"\u003eMounting: I-Line Style Plug-In\u003c\/li\u003e\n\u003cli data-section-id=\"1w3beu4\" data-start=\"1586\" data-end=\"1617\"\u003eLine Connection: I-Line Jaw\u003c\/li\u003e\n\u003cli data-section-id=\"7yjcp7\" data-start=\"1618\" data-end=\"1652\"\u003eLoad Connection: Lug Terminals\u003c\/li\u003e\n\u003cli data-section-id=\"1twgtf6\" data-start=\"1653\" data-end=\"1699\"\u003eConductor Range: 14 AWG to 2\/0 AWG (Al\/Cu)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"337yl8\" data-start=\"1701\" data-end=\"1728\"\u003eConstruction Features\u003c\/h3\u003e\n\u003cul data-start=\"1730\" data-end=\"1971\"\u003e\n\u003cli data-section-id=\"128pi9i\" data-start=\"1730\" data-end=\"1766\"\u003eCompact PowerPact B-Frame design\u003c\/li\u003e\n\u003cli data-section-id=\"1b36q1r\" data-start=\"1767\" data-end=\"1805\"\u003eDual-break rotating contact system\u003c\/li\u003e\n\u003cli data-section-id=\"dpouai\" data-start=\"1806\" data-end=\"1837\"\u003eCurrent-limiting protection\u003c\/li\u003e\n\u003cli data-section-id=\"1c60wdk\" data-start=\"1838\" data-end=\"1873\"\u003ePush-to-trip manual test button\u003c\/li\u003e\n\u003cli data-section-id=\"1cm7efm\" data-start=\"1874\" data-end=\"1918\"\u003eFixed thermal and magnetic trip elements\u003c\/li\u003e\n\u003cli data-section-id=\"15lmqzj\" data-start=\"1919\" data-end=\"1971\"\u003eI-Line plug-in installation for fast replacement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"17tovxr\" data-start=\"1973\" data-end=\"1991\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"1993\" data-end=\"2222\"\u003e\n\u003cli data-section-id=\"1b02wdy\" data-start=\"1993\" data-end=\"2039\"\u003eCommercial electrical distribution systems\u003c\/li\u003e\n\u003cli data-section-id=\"1pvw1wl\" data-start=\"2040\" data-end=\"2084\"\u003eIndustrial power panels and switchboards\u003c\/li\u003e\n\u003cli data-section-id=\"c1588\" data-start=\"2085\" data-end=\"2116\"\u003eSquare D I-Line panelboards\u003c\/li\u003e\n\u003cli data-section-id=\"fz1udj\" data-start=\"2117\" data-end=\"2152\"\u003eMotor branch circuit protection\u003c\/li\u003e\n\u003cli data-section-id=\"1b8cado\" data-start=\"2153\" data-end=\"2193\"\u003eHVAC and building power distribution\u003c\/li\u003e\n\u003cli data-section-id=\"haccx7\" data-start=\"2194\" data-end=\"2222\"\u003eOEM electrical equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"174ui70\" data-start=\"2224\" data-end=\"2251\"\u003eStandards \u0026amp; Approvals\u003c\/h3\u003e\n\u003cul data-start=\"2253\" data-end=\"2340\"\u003e\n\u003cli data-section-id=\"6d8czo\" data-start=\"2253\" data-end=\"2263\"\u003eUL 489\u003c\/li\u003e\n\u003cli data-section-id=\"12xbscc\" data-start=\"2264\" data-end=\"2283\"\u003eCSA C22.2 No. 5\u003c\/li\u003e\n\u003cli data-section-id=\"1pw3smc\" data-start=\"2284\" data-end=\"2299\"\u003eIEC 60947-2\u003c\/li\u003e\n\u003cli data-section-id=\"11cuwal\" data-start=\"2300\" data-end=\"2313\"\u003eNEMA AB 1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Square D","offers":[{"title":"NEW","offer_id":48528165273849,"sku":"BDA261001","price":645.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/BDA24020Y2-All-New-1_6871d240-f2de-4778-8c79-4b01e764cbe0.webp?v=1781421497","url":"https:\/\/mycircuitbreakers.com\/products\/square-d-bda261001-powerpact-b-circuit-breaker-2-pole-100a-thermal-magnetic-i-line-600v-class","provider":"My Circuit Breakers","version":"1.0","type":"link"}