{"product_id":"square-d-bdl36020lu-powerpact-b-circuit-breaker-3-pole-20a-thermal-magnetic-feed-thru-everlink-terminals","title":"Square D BDL36020LU PowerPact B Circuit Breaker – 3 Pole – 20A – Thermal Magnetic – Feed-Thru – EverLink Terminals","description":"\u003cp data-start=\"138\" data-end=\"577\"\u003eThe Square D BDL36020LU is a PowerPact B-frame molded case circuit breaker manufactured by Schneider Electric, designed for reliable overcurrent protection in commercial and industrial three-phase electrical distribution systems. This 3-pole, 20A breaker provides thermal-magnetic (LI) protection with fixed Long-Time and Instantaneous tripping, ensuring dependable operation under overload and short-circuit conditions.\u003c\/p\u003e\n\u003cp data-start=\"579\" data-end=\"963\"\u003eThis LU variant features an enhanced feed-thru design with EverLink terminals and an additional control wire terminal on the line-side EverLink lug, making it suitable for applications requiring auxiliary control wiring integration. The breaker supports flexible installation via DIN rail or screw-plate mounting and maintains compact B-frame efficiency for space-saving panel design.\u003c\/p\u003e\n\u003ch3 data-section-id=\"e5mrjc\" data-start=\"965\" data-end=\"985\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-start=\"987\" data-end=\"1382\"\u003e\n\u003cli data-section-id=\"1ii30bw\" data-start=\"987\" data-end=\"1006\"\u003eBrand: Square D\u003c\/li\u003e\n\u003cli data-section-id=\"f8032d\" data-start=\"1007\" data-end=\"1054\"\u003eManufacturer: Schneider Electric \/ Square D\u003c\/li\u003e\n\u003cli data-section-id=\"1xiuiox\" data-start=\"1055\" data-end=\"1089\"\u003eSeries: PowerPact B (BDL Type)\u003c\/li\u003e\n\u003cli data-section-id=\"1833pmq\" data-start=\"1090\" data-end=\"1117\"\u003ePart Number: BDL36020LU\u003c\/li\u003e\n\u003cli data-section-id=\"6rlgrk\" data-start=\"1118\" data-end=\"1162\"\u003eType: Molded Case Circuit Breaker (MCCB)\u003c\/li\u003e\n\u003cli data-section-id=\"ksy8o4\" data-start=\"1163\" data-end=\"1175\"\u003ePoles: 3\u003c\/li\u003e\n\u003cli data-section-id=\"zj0lby\" data-start=\"1176\" data-end=\"1200\"\u003eAmperage Rating: 20A\u003c\/li\u003e\n\u003cli data-section-id=\"179harl\" data-start=\"1201\" data-end=\"1219\"\u003ePhase: 3 Phase\u003c\/li\u003e\n\u003cli data-section-id=\"a6fqs4\" data-start=\"1220\" data-end=\"1278\"\u003eVoltage Rating: 600V Class (up to 600Y\/347VAC systems)\u003c\/li\u003e\n\u003cli data-section-id=\"v9ec1g\" data-start=\"1279\" data-end=\"1333\"\u003eMounting Style: Feed-Thru \/ DIN Rail \/ Screw Mount\u003c\/li\u003e\n\u003cli data-section-id=\"3mau85\" data-start=\"1334\" data-end=\"1382\"\u003eTerminal Type: EverLink Lugs (Line and Load)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"oy7toc\" data-start=\"1384\" data-end=\"1408\"\u003eElectrical Ratings\u003c\/h3\u003e\n\u003cul data-start=\"1410\" data-end=\"1620\"\u003e\n\u003cli data-section-id=\"r6bibv\" data-start=\"1410\" data-end=\"1487\"\u003eInterrupting Capacity (AIC):\n\u003cul data-start=\"1445\" data-end=\"1487\"\u003e\n\u003cli data-section-id=\"1d6wag3\" data-start=\"1445\" data-end=\"1462\"\u003e18kA @ 480VAC\u003c\/li\u003e\n\u003cli data-section-id=\"9k9otf\" data-start=\"1465\" data-end=\"1487\"\u003e14kA @ 600Y\/347VAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"g2iaqk\" data-start=\"1489\" data-end=\"1526\"\u003eProtection Type: Thermal Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"19rdzo9\" data-start=\"1527\" data-end=\"1579\"\u003eTrip Functions: Long-Time and Instantaneous (LI)\u003c\/li\u003e\n\u003cli data-section-id=\"jbg54q\" data-start=\"1580\" data-end=\"1620\"\u003eContinuous Current Rating: 80% Rated\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1t5od0y\" data-start=\"1622\" data-end=\"1646\"\u003eConnection Details\u003c\/h3\u003e\n\u003cul data-start=\"1648\" data-end=\"1853\"\u003e\n\u003cli data-section-id=\"1gveroo\" data-start=\"1648\" data-end=\"1678\"\u003eConnection Type: Feed-Thru\u003c\/li\u003e\n\u003cli data-section-id=\"1tpw7um\" data-start=\"1679\" data-end=\"1725\"\u003eLine\/Load Termination: EverLink Lug System\u003c\/li\u003e\n\u003cli data-section-id=\"ekg4lq\" data-start=\"1726\" data-end=\"1794\"\u003eSpecial Feature: Control wire terminal on line-side EverLink lug\u003c\/li\u003e\n\u003cli data-section-id=\"1n30y6i\" data-start=\"1795\" data-end=\"1853\"\u003eInstallation Options: DIN rail or screw-plate mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"337yl8\" data-start=\"1855\" data-end=\"1882\"\u003eConstruction Features\u003c\/h3\u003e\n\u003cul data-start=\"1884\" data-end=\"2150\"\u003e\n\u003cli data-section-id=\"x9nql2\" data-start=\"1884\" data-end=\"1920\"\u003eCompact PowerPact B-frame design\u003c\/li\u003e\n\u003cli data-section-id=\"1b36q1r\" data-start=\"1921\" data-end=\"1959\"\u003eDual-break rotating contact system\u003c\/li\u003e\n\u003cli data-section-id=\"dpouai\" data-start=\"1960\" data-end=\"1991\"\u003eCurrent-limiting protection\u003c\/li\u003e\n\u003cli data-section-id=\"1c60wdk\" data-start=\"1992\" data-end=\"2027\"\u003ePush-to-trip manual test button\u003c\/li\u003e\n\u003cli data-section-id=\"lufrd0\" data-start=\"2028\" data-end=\"2074\"\u003eEverLink creep-compensating lug technology\u003c\/li\u003e\n\u003cli data-section-id=\"1xeho7v\" data-start=\"2075\" data-end=\"2108\"\u003eNon-interchangeable trip unit\u003c\/li\u003e\n\u003cli data-section-id=\"y31k4k\" data-start=\"2109\" data-end=\"2150\"\u003eEnhanced LU control wiring capability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"17tovxr\" data-start=\"2152\" data-end=\"2170\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"2172\" data-end=\"2438\"\u003e\n\u003cli data-section-id=\"1y3a1f1\" data-start=\"2172\" data-end=\"2218\"\u003eIndustrial electrical distribution systems\u003c\/li\u003e\n\u003cli data-section-id=\"qxo3qm\" data-start=\"2219\" data-end=\"2246\"\u003eCommercial power panels\u003c\/li\u003e\n\u003cli data-section-id=\"bf4z71\" data-start=\"2247\" data-end=\"2269\"\u003eOEM control panels\u003c\/li\u003e\n\u003cli data-section-id=\"101b7rn\" data-start=\"2270\" data-end=\"2305\"\u003eHVAC and motor control circuits\u003c\/li\u003e\n\u003cli data-section-id=\"q5377l\" data-start=\"2306\" data-end=\"2338\"\u003eBranch and feeder protection\u003c\/li\u003e\n\u003cli data-section-id=\"1le29mk\" data-start=\"2339\" data-end=\"2398\"\u003eAutomation systems requiring control wiring integration\u003c\/li\u003e\n\u003cli data-section-id=\"175rm4a\" data-start=\"2399\" data-end=\"2438\"\u003eSquare D PowerPact panel assemblies\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"174ui70\" data-start=\"2440\" data-end=\"2467\"\u003eStandards \u0026amp; Approvals\u003c\/h3\u003e\n\u003cul data-start=\"2469\" data-end=\"2564\"\u003e\n\u003cli data-section-id=\"6d8czo\" data-start=\"2469\" data-end=\"2479\"\u003eUL 489\u003c\/li\u003e\n\u003cli data-section-id=\"12xbscc\" data-start=\"2480\" data-end=\"2499\"\u003eCSA C22.2 No. 5\u003c\/li\u003e\n\u003cli data-section-id=\"1pw3smc\" data-start=\"2500\" data-end=\"2515\"\u003eIEC 60947-2\u003c\/li\u003e\n\u003cli data-section-id=\"11cuwal\" data-start=\"2516\" data-end=\"2529\"\u003eNEMA AB 1\u003c\/li\u003e\n\u003cli data-section-id=\"qpvj7l\" data-start=\"2530\" data-end=\"2546\"\u003eCE compliant\u003c\/li\u003e\n\u003cli data-section-id=\"1ntnl1f\" data-start=\"2547\" data-end=\"2564\"\u003eNOM certified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2566\" data-end=\"2582\"\u003e\u003cstrong data-start=\"2566\" data-end=\"2580\"\u003eApprovals:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2583\" data-end=\"2646\"\u003e\n\u003cli data-section-id=\"1w9xzw2\" data-start=\"2583\" data-end=\"2596\"\u003eUL Listed\u003c\/li\u003e\n\u003cli data-section-id=\"breav2\" data-start=\"2597\" data-end=\"2614\"\u003eCSA Certified\u003c\/li\u003e\n\u003cli data-section-id=\"n6bouy\" data-start=\"2615\" data-end=\"2628\"\u003eCE Marked\u003c\/li\u003e\n\u003cli data-section-id=\"1nx0unc\" data-start=\"2629\" data-end=\"2646\"\u003eIEC Compliant\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Square D","offers":[{"title":"NEW","offer_id":48528198992121,"sku":"BDL36020LU","price":586.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/BDL36015-New-1_2338e6bb-b21f-4510-82d6-3fda1316b658.webp?v=1781424660","url":"https:\/\/mycircuitbreakers.com\/products\/square-d-bdl36020lu-powerpact-b-circuit-breaker-3-pole-20a-thermal-magnetic-feed-thru-everlink-terminals","provider":"My Circuit Breakers","version":"1.0","type":"link"}