{"product_id":"square-d-bdl36045-powerpact-b-circuit-breaker-3-pole-45a-thermal-magnetic-unit-mount-everlink-terminals","title":"Square D BDL36045 PowerPact B Circuit Breaker – 3 Pole – 45A – Thermal Magnetic – Unit Mount – EverLink Terminals","description":"\u003cp data-start=\"137\" data-end=\"590\"\u003eThe Square D BDL36045 is a PowerPact B-frame molded case circuit breaker manufactured by Schneider Electric, designed to provide reliable overcurrent protection for industrial and commercial three-phase electrical distribution systems. This 3-pole, 45A breaker delivers thermal-magnetic (LI) protection with fixed Long-Time and Instantaneous trip functions, ensuring dependable performance under overload and short-circuit conditions.\u003c\/p\u003e\n\u003cp data-start=\"592\" data-end=\"995\"\u003eBuilt as a unit-mount device, the BDL36045 supports flexible installation using DIN rail or back-pan mounting systems. It is designed as a direct replacement for legacy FAL36045 breakers, making it suitable for retrofit applications in existing switchboards. Its EverLink lug technology helps prevent conductor loosening caused by vibration and thermal cycling, improving long-term connection stability.\u003c\/p\u003e\n\u003ch3 data-section-id=\"e5mrjc\" data-start=\"997\" data-end=\"1017\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-start=\"1019\" data-end=\"1394\"\u003e\n\u003cli data-section-id=\"1ii30bw\" data-start=\"1019\" data-end=\"1038\"\u003eBrand: Square D\u003c\/li\u003e\n\u003cli data-section-id=\"1mzzcj3\" data-start=\"1039\" data-end=\"1075\"\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n\u003cli data-section-id=\"1xiuiox\" data-start=\"1076\" data-end=\"1110\"\u003eSeries: PowerPact B (BDL Type)\u003c\/li\u003e\n\u003cli data-section-id=\"1bpz8k8\" data-start=\"1111\" data-end=\"1136\"\u003ePart Number: BDL36045\u003c\/li\u003e\n\u003cli data-section-id=\"6rlgrk\" data-start=\"1137\" data-end=\"1181\"\u003eType: Molded Case Circuit Breaker (MCCB)\u003c\/li\u003e\n\u003cli data-section-id=\"ksy8o4\" data-start=\"1182\" data-end=\"1194\"\u003ePoles: 3\u003c\/li\u003e\n\u003cli data-section-id=\"zeufrx\" data-start=\"1195\" data-end=\"1219\"\u003eAmperage Rating: 45A\u003c\/li\u003e\n\u003cli data-section-id=\"179harl\" data-start=\"1220\" data-end=\"1238\"\u003ePhase: 3 Phase\u003c\/li\u003e\n\u003cli data-section-id=\"a6fqs4\" data-start=\"1239\" data-end=\"1297\"\u003eVoltage Rating: 600V Class (up to 600Y\/347VAC systems)\u003c\/li\u003e\n\u003cli data-section-id=\"168gnfr\" data-start=\"1298\" data-end=\"1361\"\u003eMounting Style: Unit Mount (DIN rail \/ back-pan compatible)\u003c\/li\u003e\n\u003cli data-section-id=\"yhkvdz\" data-start=\"1362\" data-end=\"1394\"\u003eTerminal Type: EverLink Lugs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"oy7toc\" data-start=\"1396\" data-end=\"1420\"\u003eElectrical Ratings\u003c\/h3\u003e\n\u003cul data-start=\"1422\" data-end=\"1667\"\u003e\n\u003cli data-section-id=\"3b94cy\" data-start=\"1422\" data-end=\"1534\"\u003eInterrupting Capacity (AIC):\n\u003cul data-start=\"1457\" data-end=\"1534\"\u003e\n\u003cli data-section-id=\"1d6wag3\" data-start=\"1457\" data-end=\"1474\"\u003e18kA @ 480VAC\u003c\/li\u003e\n\u003cli data-section-id=\"9k9otf\" data-start=\"1477\" data-end=\"1499\"\u003e14kA @ 600Y\/347VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1mzwegm\" data-start=\"1502\" data-end=\"1534\"\u003e25kA @ 240VAC (as specified)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"g2iaqk\" data-start=\"1536\" data-end=\"1573\"\u003eProtection Type: Thermal Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"19rdzo9\" data-start=\"1574\" data-end=\"1626\"\u003eTrip Functions: Long-Time and Instantaneous (LI)\u003c\/li\u003e\n\u003cli data-section-id=\"jbg54q\" data-start=\"1627\" data-end=\"1667\"\u003eContinuous Current Rating: 80% Rated\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1t5od0y\" data-start=\"1669\" data-end=\"1693\"\u003eConnection Details\u003c\/h3\u003e\n\u003cul data-start=\"1695\" data-end=\"1888\"\u003e\n\u003cli data-section-id=\"1adunpz\" data-start=\"1695\" data-end=\"1726\"\u003eConnection Type: Unit Mount\u003c\/li\u003e\n\u003cli data-section-id=\"1tpw7um\" data-start=\"1727\" data-end=\"1773\"\u003eLine\/Load Termination: EverLink Lug System\u003c\/li\u003e\n\u003cli data-section-id=\"4u4ko2\" data-start=\"1774\" data-end=\"1829\"\u003eInstallation Options: DIN rail or back-pan mounting\u003c\/li\u003e\n\u003cli data-section-id=\"1yyrph5\" data-start=\"1830\" data-end=\"1888\"\u003eRetrofit Compatibility: Replaces legacy FAL36045 units\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"337yl8\" data-start=\"1890\" data-end=\"1917\"\u003eConstruction Features\u003c\/h3\u003e\n\u003cul data-start=\"1919\" data-end=\"2193\"\u003e\n\u003cli data-section-id=\"x9nql2\" data-start=\"1919\" data-end=\"1955\"\u003eCompact PowerPact B-frame design\u003c\/li\u003e\n\u003cli data-section-id=\"1b36q1r\" data-start=\"1956\" data-end=\"1994\"\u003eDual-break rotating contact system\u003c\/li\u003e\n\u003cli data-section-id=\"dpouai\" data-start=\"1995\" data-end=\"2026\"\u003eCurrent-limiting protection\u003c\/li\u003e\n\u003cli data-section-id=\"14mx1vg\" data-start=\"2027\" data-end=\"2064\"\u003ePush-to-trip manual test function\u003c\/li\u003e\n\u003cli data-section-id=\"lufrd0\" data-start=\"2065\" data-end=\"2111\"\u003eEverLink creep-compensating lug technology\u003c\/li\u003e\n\u003cli data-section-id=\"lz8c3o\" data-start=\"2112\" data-end=\"2159\"\u003eHigh vibration resistance connection system\u003c\/li\u003e\n\u003cli data-section-id=\"1xeho7v\" data-start=\"2160\" data-end=\"2193\"\u003eNon-interchangeable trip unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"17tovxr\" data-start=\"2195\" data-end=\"2213\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"2215\" data-end=\"2451\"\u003e\n\u003cli data-section-id=\"1y3a1f1\" data-start=\"2215\" data-end=\"2261\"\u003eIndustrial electrical distribution systems\u003c\/li\u003e\n\u003cli data-section-id=\"mldaxb\" data-start=\"2262\" data-end=\"2289\"\u003eCommercial switchboards\u003c\/li\u003e\n\u003cli data-section-id=\"bf4z71\" data-start=\"2290\" data-end=\"2312\"\u003eOEM control panels\u003c\/li\u003e\n\u003cli data-section-id=\"blj8he\" data-start=\"2313\" data-end=\"2345\"\u003eHVAC and motor load circuits\u003c\/li\u003e\n\u003cli data-section-id=\"q5377l\" data-start=\"2346\" data-end=\"2378\"\u003eBranch and feeder protection\u003c\/li\u003e\n\u003cli data-section-id=\"1h9flrw\" data-start=\"2379\" data-end=\"2417\"\u003eRetrofit replacement installations\u003c\/li\u003e\n\u003cli data-section-id=\"15czlws\" data-start=\"2418\" data-end=\"2451\"\u003eSquare D PowerPact assemblies\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"174ui70\" data-start=\"2453\" data-end=\"2480\"\u003eStandards \u0026amp; Approvals\u003c\/h3\u003e\n\u003cul data-start=\"2482\" data-end=\"2606\"\u003e\n\u003cli data-section-id=\"6d8czo\" data-start=\"2482\" data-end=\"2492\"\u003eUL 489\u003c\/li\u003e\n\u003cli data-section-id=\"12xbscc\" data-start=\"2493\" data-end=\"2512\"\u003eCSA C22.2 No. 5\u003c\/li\u003e\n\u003cli data-section-id=\"1pw3smc\" data-start=\"2513\" data-end=\"2528\"\u003eIEC 60947-2\u003c\/li\u003e\n\u003cli data-section-id=\"11cuwal\" data-start=\"2529\" data-end=\"2542\"\u003eNEMA AB 1\u003c\/li\u003e\n\u003cli data-section-id=\"1a71x6w\" data-start=\"2543\" data-end=\"2557\"\u003eGB 14048.2\u003c\/li\u003e\n\u003cli data-section-id=\"ewodza\" data-start=\"2558\" data-end=\"2571\"\u003eNMX J-266\u003c\/li\u003e\n\u003cli data-section-id=\"qpvj7l\" data-start=\"2572\" data-end=\"2588\"\u003eCE compliant\u003c\/li\u003e\n\u003cli data-section-id=\"1ntnl1f\" data-start=\"2589\" data-end=\"2606\"\u003eNOM certified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2608\" data-end=\"2624\"\u003e\u003cstrong data-start=\"2608\" data-end=\"2622\"\u003eApprovals:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2625\" data-end=\"2688\"\u003e\n\u003cli data-section-id=\"1w9xzw2\" data-start=\"2625\" data-end=\"2638\"\u003eUL Listed\u003c\/li\u003e\n\u003cli data-section-id=\"breav2\" data-start=\"2639\" data-end=\"2656\"\u003eCSA Certified\u003c\/li\u003e\n\u003cli data-section-id=\"n6bouy\" data-start=\"2657\" data-end=\"2670\"\u003eCE Marked\u003c\/li\u003e\n\u003cli data-section-id=\"1nx0unc\" data-start=\"2671\" data-end=\"2688\"\u003eIEC Compliant\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Square D","offers":[{"title":"NEW","offer_id":48528200564985,"sku":"BDL36045","price":693.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/BDL36045-3-Pole-Circuit-Breaker_SquareD_1.webp?v=1781425707","url":"https:\/\/mycircuitbreakers.com\/products\/square-d-bdl36045-powerpact-b-circuit-breaker-3-pole-45a-thermal-magnetic-unit-mount-everlink-terminals","provider":"My Circuit Breakers","version":"1.0","type":"link"}