{"product_id":"square-d-bdl36060-powerpact-b-circuit-breaker-3-pole-60a-thermal-magnetic-feed-thru-everlink-terminals","title":"Square D BDL36060 PowerPact B Circuit Breaker – 3 Pole – 60A – Thermal Magnetic – Feed-Thru – EverLink Terminals","description":"\u003cp data-start=\"136\" data-end=\"576\"\u003eThe Square D BDL36060 is a PowerPact B-frame molded case circuit breaker manufactured by Schneider Electric, designed for dependable overcurrent protection in commercial and industrial three-phase electrical distribution systems. This 3-pole, 60A breaker provides thermal-magnetic (LI) protection with fixed Long-Time and Instantaneous trip functions, ensuring reliable response to overloads and short-circuit conditions.\u003c\/p\u003e\n\u003cp data-start=\"578\" data-end=\"990\"\u003eBuilt in a feed-thru configuration, the BDL36060 supports flexible installation using DIN rail mounting or back-pan mounting. Its EverLink lug technology on both line and load sides improves long-term connection stability by reducing conductor loosening caused by vibration and thermal cycling. The compact B-frame design ensures efficient panel space utilization while maintaining strong electrical performance.\u003c\/p\u003e\n\u003ch3 data-section-id=\"e5mrjc\" data-start=\"992\" data-end=\"1012\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-start=\"1014\" data-end=\"1396\"\u003e\n\u003cli data-section-id=\"1ii30bw\" data-start=\"1014\" data-end=\"1033\"\u003eBrand: Square D\u003c\/li\u003e\n\u003cli data-section-id=\"1mzzcj3\" data-start=\"1034\" data-end=\"1070\"\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n\u003cli data-section-id=\"1xiuiox\" data-start=\"1071\" data-end=\"1105\"\u003eSeries: PowerPact B (BDL Type)\u003c\/li\u003e\n\u003cli data-section-id=\"1bq0ulb\" data-start=\"1106\" data-end=\"1131\"\u003ePart Number: BDL36060\u003c\/li\u003e\n\u003cli data-section-id=\"6rlgrk\" data-start=\"1132\" data-end=\"1176\"\u003eType: Molded Case Circuit Breaker (MCCB)\u003c\/li\u003e\n\u003cli data-section-id=\"ksy8o4\" data-start=\"1177\" data-end=\"1189\"\u003ePoles: 3\u003c\/li\u003e\n\u003cli data-section-id=\"zg6x2y\" data-start=\"1190\" data-end=\"1214\"\u003eAmperage Rating: 60A\u003c\/li\u003e\n\u003cli data-section-id=\"179harl\" data-start=\"1215\" data-end=\"1233\"\u003ePhase: 3 Phase\u003c\/li\u003e\n\u003cli data-section-id=\"a6fqs4\" data-start=\"1234\" data-end=\"1292\"\u003eVoltage Rating: 600V Class (up to 600Y\/347VAC systems)\u003c\/li\u003e\n\u003cli data-section-id=\"v9ec1g\" data-start=\"1293\" data-end=\"1347\"\u003eMounting Style: Feed-Thru \/ DIN Rail \/ Screw Mount\u003c\/li\u003e\n\u003cli data-section-id=\"3mau85\" data-start=\"1348\" data-end=\"1396\"\u003eTerminal Type: EverLink Lugs (Line and Load)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"oy7toc\" data-start=\"1398\" data-end=\"1422\"\u003eElectrical Ratings\u003c\/h3\u003e\n\u003cul data-start=\"1424\" data-end=\"1634\"\u003e\n\u003cli data-section-id=\"r6bibv\" data-start=\"1424\" data-end=\"1501\"\u003eInterrupting Capacity (AIC):\n\u003cul data-start=\"1459\" data-end=\"1501\"\u003e\n\u003cli data-section-id=\"1d6wag3\" data-start=\"1459\" data-end=\"1476\"\u003e18kA @ 480VAC\u003c\/li\u003e\n\u003cli data-section-id=\"9k9otf\" data-start=\"1479\" data-end=\"1501\"\u003e14kA @ 600Y\/347VAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"g2iaqk\" data-start=\"1503\" data-end=\"1540\"\u003eProtection Type: Thermal Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"19rdzo9\" data-start=\"1541\" data-end=\"1593\"\u003eTrip Functions: Long-Time and Instantaneous (LI)\u003c\/li\u003e\n\u003cli data-section-id=\"jbg54q\" data-start=\"1594\" data-end=\"1634\"\u003eContinuous Current Rating: 80% Rated\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1t5od0y\" data-start=\"1636\" data-end=\"1660\"\u003eConnection Details\u003c\/h3\u003e\n\u003cul data-start=\"1662\" data-end=\"1804\"\u003e\n\u003cli data-section-id=\"1gveroo\" data-start=\"1662\" data-end=\"1692\"\u003eConnection Type: Feed-Thru\u003c\/li\u003e\n\u003cli data-section-id=\"1tpw7um\" data-start=\"1693\" data-end=\"1739\"\u003eLine\/Load Termination: EverLink Lug System\u003c\/li\u003e\n\u003cli data-section-id=\"mteddb\" data-start=\"1740\" data-end=\"1804\"\u003eInstallation Options: Back-pan mounting or DIN rail mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"337yl8\" data-start=\"1806\" data-end=\"1833\"\u003eConstruction Features\u003c\/h3\u003e\n\u003cul data-start=\"1835\" data-end=\"2101\"\u003e\n\u003cli data-section-id=\"x9nql2\" data-start=\"1835\" data-end=\"1871\"\u003eCompact PowerPact B-frame design\u003c\/li\u003e\n\u003cli data-section-id=\"1b36q1r\" data-start=\"1872\" data-end=\"1910\"\u003eDual-break rotating contact system\u003c\/li\u003e\n\u003cli data-section-id=\"dpouai\" data-start=\"1911\" data-end=\"1942\"\u003eCurrent-limiting protection\u003c\/li\u003e\n\u003cli data-section-id=\"1c60wdk\" data-start=\"1943\" data-end=\"1978\"\u003ePush-to-trip manual test button\u003c\/li\u003e\n\u003cli data-section-id=\"lufrd0\" data-start=\"1979\" data-end=\"2025\"\u003eEverLink creep-compensating lug technology\u003c\/li\u003e\n\u003cli data-section-id=\"1xeho7v\" data-start=\"2026\" data-end=\"2059\"\u003eNon-interchangeable trip unit\u003c\/li\u003e\n\u003cli data-section-id=\"he10g3\" data-start=\"2060\" data-end=\"2101\"\u003eIndustrial-grade durable construction\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"17tovxr\" data-start=\"2103\" data-end=\"2121\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"2123\" data-end=\"2337\"\u003e\n\u003cli data-section-id=\"1y3a1f1\" data-start=\"2123\" data-end=\"2169\"\u003eIndustrial electrical distribution systems\u003c\/li\u003e\n\u003cli data-section-id=\"qxo3qm\" data-start=\"2170\" data-end=\"2197\"\u003eCommercial power panels\u003c\/li\u003e\n\u003cli data-section-id=\"bf4z71\" data-start=\"2198\" data-end=\"2220\"\u003eOEM control panels\u003c\/li\u003e\n\u003cli data-section-id=\"1dp3ymd\" data-start=\"2221\" data-end=\"2264\"\u003eHVAC systems and motor control circuits\u003c\/li\u003e\n\u003cli data-section-id=\"q5377l\" data-start=\"2265\" data-end=\"2297\"\u003eBranch and feeder protection\u003c\/li\u003e\n\u003cli data-section-id=\"175rm4a\" data-start=\"2298\" data-end=\"2337\"\u003eSquare D PowerPact panel assemblies\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"174ui70\" data-start=\"2339\" data-end=\"2366\"\u003eStandards \u0026amp; Approvals\u003c\/h3\u003e\n\u003cul data-start=\"2368\" data-end=\"2463\"\u003e\n\u003cli data-section-id=\"6d8czo\" data-start=\"2368\" data-end=\"2378\"\u003eUL 489\u003c\/li\u003e\n\u003cli data-section-id=\"12xbscc\" data-start=\"2379\" data-end=\"2398\"\u003eCSA C22.2 No. 5\u003c\/li\u003e\n\u003cli data-section-id=\"1pw3smc\" data-start=\"2399\" data-end=\"2414\"\u003eIEC 60947-2\u003c\/li\u003e\n\u003cli data-section-id=\"11cuwal\" data-start=\"2415\" data-end=\"2428\"\u003eNEMA AB 1\u003c\/li\u003e\n\u003cli data-section-id=\"qpvj7l\" data-start=\"2429\" data-end=\"2445\"\u003eCE compliant\u003c\/li\u003e\n\u003cli data-section-id=\"1ntnl1f\" data-start=\"2446\" data-end=\"2463\"\u003eNOM certified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2465\" data-end=\"2481\"\u003e\u003cstrong data-start=\"2465\" data-end=\"2479\"\u003eApprovals:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2482\" data-end=\"2545\"\u003e\n\u003cli data-section-id=\"1w9xzw2\" data-start=\"2482\" data-end=\"2495\"\u003eUL Listed\u003c\/li\u003e\n\u003cli data-section-id=\"breav2\" data-start=\"2496\" data-end=\"2513\"\u003eCSA Certified\u003c\/li\u003e\n\u003cli data-section-id=\"n6bouy\" data-start=\"2514\" data-end=\"2527\"\u003eCE Marked\u003c\/li\u003e\n\u003cli data-section-id=\"1nx0unc\" data-start=\"2528\" data-end=\"2545\"\u003eIEC Compliant\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Square D","offers":[{"title":"NEW","offer_id":48528200761593,"sku":"BDL36060","price":693.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/BDL36015-New-1_d602aa8f-263c-4c2c-baec-0e257eaef65f.webp?v=1781425983","url":"https:\/\/mycircuitbreakers.com\/products\/square-d-bdl36060-powerpact-b-circuit-breaker-3-pole-60a-thermal-magnetic-feed-thru-everlink-terminals","provider":"My Circuit Breakers","version":"1.0","type":"link"}