{"product_id":"square-d-bdl36070-powerpact-b-circuit-breaker-3-pole-70a-thermal-magnetic-feed-thru-everlink-terminals","title":"Square D BDL36070 PowerPact B Circuit Breaker – 3 Pole – 70A – Thermal Magnetic – Feed-Thru – EverLink Terminals","description":"\u003cp data-start=\"136\" data-end=\"579\"\u003eThe Square D BDL36070 is a PowerPact B-frame molded case circuit breaker manufactured by Schneider Electric, designed for dependable overcurrent protection in industrial and commercial three-phase electrical distribution systems. This 3-pole, 70A breaker delivers thermal-magnetic (LI) protection with fixed Long-Time and Instantaneous trip functions, ensuring reliable operation under overload and short-circuit conditions.\u003c\/p\u003e\n\u003cp data-start=\"581\" data-end=\"1000\"\u003eBuilt with a feed-thru configuration, the BDL36070 supports flexible installation using DIN rail mounting or back-pan mounting options. Its EverLink lug technology on both line and load sides enhances long-term connection reliability by reducing conductor loosening caused by vibration and thermal cycling. The compact B-frame design ensures efficient use of panel space while maintaining strong electrical performance.\u003c\/p\u003e\n\u003ch3 data-section-id=\"e5mrjc\" data-start=\"1002\" data-end=\"1022\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-start=\"1024\" data-end=\"1417\"\u003e\n\u003cli data-section-id=\"1ii30bw\" data-start=\"1024\" data-end=\"1043\"\u003eBrand: Square D\u003c\/li\u003e\n\u003cli data-section-id=\"f8032d\" data-start=\"1044\" data-end=\"1091\"\u003eManufacturer: Schneider Electric \/ Square D\u003c\/li\u003e\n\u003cli data-section-id=\"1xiuiox\" data-start=\"1092\" data-end=\"1126\"\u003eSeries: PowerPact B (BDL Type)\u003c\/li\u003e\n\u003cli data-section-id=\"1bq1kou\" data-start=\"1127\" data-end=\"1152\"\u003ePart Number: BDL36070\u003c\/li\u003e\n\u003cli data-section-id=\"6rlgrk\" data-start=\"1153\" data-end=\"1197\"\u003eType: Molded Case Circuit Breaker (MCCB)\u003c\/li\u003e\n\u003cli data-section-id=\"ksy8o4\" data-start=\"1198\" data-end=\"1210\"\u003ePoles: 3\u003c\/li\u003e\n\u003cli data-section-id=\"zguvzv\" data-start=\"1211\" data-end=\"1235\"\u003eAmperage Rating: 70A\u003c\/li\u003e\n\u003cli data-section-id=\"179harl\" data-start=\"1236\" data-end=\"1254\"\u003ePhase: 3 Phase\u003c\/li\u003e\n\u003cli data-section-id=\"a6fqs4\" data-start=\"1255\" data-end=\"1313\"\u003eVoltage Rating: 600V Class (up to 600Y\/347VAC systems)\u003c\/li\u003e\n\u003cli data-section-id=\"v9ec1g\" data-start=\"1314\" data-end=\"1368\"\u003eMounting Style: Feed-Thru \/ DIN Rail \/ Screw Mount\u003c\/li\u003e\n\u003cli data-section-id=\"3mau85\" data-start=\"1369\" data-end=\"1417\"\u003eTerminal Type: EverLink Lugs (Line and Load)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"oy7toc\" data-start=\"1419\" data-end=\"1443\"\u003eElectrical Ratings\u003c\/h3\u003e\n\u003cul data-start=\"1445\" data-end=\"1655\"\u003e\n\u003cli data-section-id=\"r6bibv\" data-start=\"1445\" data-end=\"1522\"\u003eInterrupting Capacity (AIC):\n\u003cul data-start=\"1480\" data-end=\"1522\"\u003e\n\u003cli data-section-id=\"1d6wag3\" data-start=\"1480\" data-end=\"1497\"\u003e18kA @ 480VAC\u003c\/li\u003e\n\u003cli data-section-id=\"9k9otf\" data-start=\"1500\" data-end=\"1522\"\u003e14kA @ 600Y\/347VAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"g2iaqk\" data-start=\"1524\" data-end=\"1561\"\u003eProtection Type: Thermal Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"19rdzo9\" data-start=\"1562\" data-end=\"1614\"\u003eTrip Functions: Long-Time and Instantaneous (LI)\u003c\/li\u003e\n\u003cli data-section-id=\"jbg54q\" data-start=\"1615\" data-end=\"1655\"\u003eContinuous Current Rating: 80% Rated\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1t5od0y\" data-start=\"1657\" data-end=\"1681\"\u003eConnection Details\u003c\/h3\u003e\n\u003cul data-start=\"1683\" data-end=\"1825\"\u003e\n\u003cli data-section-id=\"1gveroo\" data-start=\"1683\" data-end=\"1713\"\u003eConnection Type: Feed-Thru\u003c\/li\u003e\n\u003cli data-section-id=\"1tpw7um\" data-start=\"1714\" data-end=\"1760\"\u003eLine\/Load Termination: EverLink Lug System\u003c\/li\u003e\n\u003cli data-section-id=\"mteddb\" data-start=\"1761\" data-end=\"1825\"\u003eInstallation Options: Back-pan mounting or DIN rail mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"337yl8\" data-start=\"1827\" data-end=\"1854\"\u003eConstruction Features\u003c\/h3\u003e\n\u003cul data-start=\"1856\" data-end=\"2121\"\u003e\n\u003cli data-section-id=\"x9nql2\" data-start=\"1856\" data-end=\"1892\"\u003eCompact PowerPact B-frame design\u003c\/li\u003e\n\u003cli data-section-id=\"1b36q1r\" data-start=\"1893\" data-end=\"1931\"\u003eDual-break rotating contact system\u003c\/li\u003e\n\u003cli data-section-id=\"dpouai\" data-start=\"1932\" data-end=\"1963\"\u003eCurrent-limiting protection\u003c\/li\u003e\n\u003cli data-section-id=\"1c60wdk\" data-start=\"1964\" data-end=\"1999\"\u003ePush-to-trip manual test button\u003c\/li\u003e\n\u003cli data-section-id=\"lufrd0\" data-start=\"2000\" data-end=\"2046\"\u003eEverLink creep-compensating lug technology\u003c\/li\u003e\n\u003cli data-section-id=\"1xeho7v\" data-start=\"2047\" data-end=\"2080\"\u003eNon-interchangeable trip unit\u003c\/li\u003e\n\u003cli data-section-id=\"1rr2hws\" data-start=\"2081\" data-end=\"2121\"\u003eIndustrial-grade rugged construction\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"17tovxr\" data-start=\"2123\" data-end=\"2141\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"2143\" data-end=\"2357\"\u003e\n\u003cli data-section-id=\"1y3a1f1\" data-start=\"2143\" data-end=\"2189\"\u003eIndustrial electrical distribution systems\u003c\/li\u003e\n\u003cli data-section-id=\"qxo3qm\" data-start=\"2190\" data-end=\"2217\"\u003eCommercial power panels\u003c\/li\u003e\n\u003cli data-section-id=\"bf4z71\" data-start=\"2218\" data-end=\"2240\"\u003eOEM control panels\u003c\/li\u003e\n\u003cli data-section-id=\"1dp3ymd\" data-start=\"2241\" data-end=\"2284\"\u003eHVAC systems and motor control circuits\u003c\/li\u003e\n\u003cli data-section-id=\"q5377l\" data-start=\"2285\" data-end=\"2317\"\u003eBranch and feeder protection\u003c\/li\u003e\n\u003cli data-section-id=\"175rm4a\" data-start=\"2318\" data-end=\"2357\"\u003eSquare D PowerPact panel assemblies\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"174ui70\" data-start=\"2359\" data-end=\"2386\"\u003eStandards \u0026amp; Approvals\u003c\/h3\u003e\n\u003cul data-start=\"2388\" data-end=\"2483\"\u003e\n\u003cli data-section-id=\"6d8czo\" data-start=\"2388\" data-end=\"2398\"\u003eUL 489\u003c\/li\u003e\n\u003cli data-section-id=\"12xbscc\" data-start=\"2399\" data-end=\"2418\"\u003eCSA C22.2 No. 5\u003c\/li\u003e\n\u003cli data-section-id=\"1pw3smc\" data-start=\"2419\" data-end=\"2434\"\u003eIEC 60947-2\u003c\/li\u003e\n\u003cli data-section-id=\"11cuwal\" data-start=\"2435\" data-end=\"2448\"\u003eNEMA AB 1\u003c\/li\u003e\n\u003cli data-section-id=\"qpvj7l\" data-start=\"2449\" data-end=\"2465\"\u003eCE compliant\u003c\/li\u003e\n\u003cli data-section-id=\"1ntnl1f\" data-start=\"2466\" data-end=\"2483\"\u003eNOM certified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2485\" data-end=\"2501\"\u003e\u003cstrong data-start=\"2485\" data-end=\"2499\"\u003eApprovals:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2502\" data-end=\"2565\"\u003e\n\u003cli data-section-id=\"1w9xzw2\" data-start=\"2502\" data-end=\"2515\"\u003eUL Listed\u003c\/li\u003e\n\u003cli data-section-id=\"breav2\" data-start=\"2516\" data-end=\"2533\"\u003eCSA Certified\u003c\/li\u003e\n\u003cli data-section-id=\"n6bouy\" data-start=\"2534\" data-end=\"2547\"\u003eCE Marked\u003c\/li\u003e\n\u003cli data-section-id=\"1nx0unc\" data-start=\"2548\" data-end=\"2565\"\u003eIEC Compliant\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Square D","offers":[{"title":"NEW","offer_id":48528200958201,"sku":"BDL36070","price":919.35,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/BDL36015-New-1_4cc642c1-1fe9-48ed-8274-da0f67dc9688.webp?v=1781426187","url":"https:\/\/mycircuitbreakers.com\/products\/square-d-bdl36070-powerpact-b-circuit-breaker-3-pole-70a-thermal-magnetic-feed-thru-everlink-terminals","provider":"My Circuit Breakers","version":"1.0","type":"link"}