{"product_id":"square-d-bdl36125-powerpact-b-frame-molded-case-circuit-breaker-3-pole-125a-600v-feed-thru-thermal-magnetic-li","title":"Square D BDL36125 PowerPacT B-Frame Molded Case Circuit Breaker – 3 Pole – 125A – 600V – Feed-Thru – Thermal Magnetic (LI)","description":"\u003cp data-start=\"144\" data-end=\"586\"\u003eThe Square D BDL36125 is a PowerPacT B-Frame molded case circuit breaker designed to provide dependable overcurrent and short-circuit protection in commercial, industrial, and OEM power distribution systems. Manufactured by \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eSchneider Electric\u003c\/span\u003e\u003c\/span\u003e under the Square D brand, this 3-pole, 125A circuit breaker combines compact dimensions with robust thermal-magnetic protection for reliable circuit performance.\u003c\/p\u003e\n\u003cp data-start=\"588\" data-end=\"990\"\u003eDesigned with a feed-thru configuration, the BDL36125 features EverLink lug terminals on both the line and load sides. This patented connection technology helps compensate for conductor creep and thermal cycling, maintaining secure wire terminations over time. The breaker incorporates fixed long-time and instantaneous (LI) trip functions and a non-interchangeable trip unit for consistent protection.\u003c\/p\u003e\n\u003cp data-start=\"992\" data-end=\"1260\"\u003eIts compact B-Frame construction supports both DIN rail and screw-mounted installations, making it ideal for industrial control panels, switchboards, machinery, and electrical distribution equipment where installation flexibility and reliable protection are essential.\u003c\/p\u003e\n\u003chr data-start=\"1262\" data-end=\"1265\"\u003e\n\u003ch3 data-section-id=\"1yl5694\" data-start=\"1267\" data-end=\"1285\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-start=\"1287\" data-end=\"1808\"\u003e\n\u003cli data-section-id=\"1ii30bw\" data-start=\"1287\" data-end=\"1306\"\u003eBrand: Square D\u003c\/li\u003e\n\u003cli data-section-id=\"1mzzcj3\" data-start=\"1307\" data-end=\"1343\"\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n\u003cli data-section-id=\"1bqlrhb\" data-start=\"1344\" data-end=\"1369\"\u003ePart Number: BDL36125\u003c\/li\u003e\n\u003cli data-section-id=\"n47shu\" data-start=\"1370\" data-end=\"1399\"\u003eSeries: PowerPacT B-Frame\u003c\/li\u003e\n\u003cli data-section-id=\"6rlgrk\" data-start=\"1400\" data-end=\"1444\"\u003eType: Molded Case Circuit Breaker (MCCB)\u003c\/li\u003e\n\u003cli data-section-id=\"af1xqf\" data-start=\"1445\" data-end=\"1470\"\u003eConfiguration: 3 Pole\u003c\/li\u003e\n\u003cli data-section-id=\"179harl\" data-start=\"1471\" data-end=\"1489\"\u003ePhase: 3 Phase\u003c\/li\u003e\n\u003cli data-section-id=\"1629ap9\" data-start=\"1490\" data-end=\"1508\"\u003eAmperage: 125A\u003c\/li\u003e\n\u003cli data-section-id=\"th2r1v\" data-start=\"1509\" data-end=\"1540\"\u003eVoltage Rating: 600Y\/347VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1gveroo\" data-start=\"1541\" data-end=\"1571\"\u003eConnection Type: Feed-Thru\u003c\/li\u003e\n\u003cli data-section-id=\"105arl6\" data-start=\"1572\" data-end=\"1623\"\u003eTrip Function: LI (Long-Time and Instantaneous)\u003c\/li\u003e\n\u003cli data-section-id=\"2puffi\" data-start=\"1624\" data-end=\"1661\"\u003eTrip Technology: Thermal Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"kq3c5x\" data-start=\"1662\" data-end=\"1718\"\u003eBreaking Capacity: 18kA @ 480VAC, 14kA @ 600Y\/347VAC\u003c\/li\u003e\n\u003cli data-section-id=\"l5qh7g\" data-start=\"1719\" data-end=\"1753\"\u003eContinuous Current Rating: 80%\u003c\/li\u003e\n\u003cli data-section-id=\"nejvhs\" data-start=\"1754\" data-end=\"1783\"\u003eBreaking Capacity Code: D\u003c\/li\u003e\n\u003cli data-section-id=\"vpzr6n\" data-start=\"1784\" data-end=\"1808\"\u003eControl Type: Toggle\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1810\" data-end=\"1813\"\u003e\n\u003ch3 data-section-id=\"cn8pd9\" data-start=\"1815\" data-end=\"1841\"\u003eElectrical Connections\u003c\/h3\u003e\n\u003cul data-start=\"1843\" data-end=\"2019\"\u003e\n\u003cli data-section-id=\"gufx4y\" data-start=\"1843\" data-end=\"1874\"\u003eLine Terminal: EverLink Lug\u003c\/li\u003e\n\u003cli data-section-id=\"1h7au22\" data-start=\"1875\" data-end=\"1906\"\u003eLoad Terminal: EverLink Lug\u003c\/li\u003e\n\u003cli data-section-id=\"1xidmab\" data-start=\"1907\" data-end=\"2019\"\u003eWire Range:\n\u003cul data-start=\"1923\" data-end=\"2019\"\u003e\n\u003cli data-section-id=\"17uixyp\" data-start=\"1923\" data-end=\"1967\"\u003eAWG 6 to 2\/0 fine-stranded aluminum\/copper\u003c\/li\u003e\n\u003cli data-section-id=\"lkatba\" data-start=\"1970\" data-end=\"2019\"\u003eAWG 14 to 3\/0 rigid or stranded aluminum\/copper\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2021\" data-end=\"2024\"\u003e\n\u003ch3 data-section-id=\"1ms6uuo\" data-start=\"2026\" data-end=\"2053\"\u003eMounting \u0026amp; Construction\u003c\/h3\u003e\n\u003cul data-start=\"2055\" data-end=\"2398\"\u003e\n\u003cli data-section-id=\"1gl40ag\" data-start=\"2055\" data-end=\"2094\"\u003eMounting Type: Feed-Thru Unit Mount\u003c\/li\u003e\n\u003cli data-section-id=\"odwgjb\" data-start=\"2095\" data-end=\"2194\"\u003eInstallation Methods:\n\u003cul data-start=\"2121\" data-end=\"2194\"\u003e\n\u003cli data-section-id=\"o7ovqe\" data-start=\"2121\" data-end=\"2157\"\u003e35 mm × 15 mm symmetrical DIN rail\u003c\/li\u003e\n\u003cli data-section-id=\"jqt8z\" data-start=\"2160\" data-end=\"2194\"\u003eScrew-mounted panel installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1c2bsft\" data-start=\"2195\" data-end=\"2244\"\u003eTrip Unit: Non-Interchangeable Thermal-Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"1ufys89\" data-start=\"2245\" data-end=\"2309\"\u003eEverLink patented lug technology minimizes conductor loosening\u003c\/li\u003e\n\u003cli data-section-id=\"h48pee\" data-start=\"2310\" data-end=\"2344\"\u003eCompact PowerPacT B-Frame design\u003c\/li\u003e\n\u003cli data-section-id=\"11wuws4\" data-start=\"2345\" data-end=\"2398\"\u003eSuitable for industrial and commercial environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2400\" data-end=\"2403\"\u003e\n\u003ch3 data-section-id=\"bpec4l\" data-start=\"2405\" data-end=\"2419\"\u003eDimensions\u003c\/h3\u003e\n\u003cul data-start=\"2421\" data-end=\"2498\"\u003e\n\u003cli data-section-id=\"6tf5dn\" data-start=\"2421\" data-end=\"2440\"\u003eHeight: 5.39 in\u003c\/li\u003e\n\u003cli data-section-id=\"5hvjty\" data-start=\"2441\" data-end=\"2459\"\u003eWidth: 3.19 in\u003c\/li\u003e\n\u003cli data-section-id=\"188p3ep\" data-start=\"2460\" data-end=\"2478\"\u003eDepth: 3.15 in\u003c\/li\u003e\n\u003cli data-section-id=\"1mtiu6c\" data-start=\"2479\" data-end=\"2498\"\u003eWeight: 2.37 lb\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2500\" data-end=\"2503\"\u003e\n\u003ch3 data-section-id=\"wggvqn\" data-start=\"2505\" data-end=\"2521\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"2523\" data-end=\"2752\"\u003e\n\u003cli data-section-id=\"1b935sd\" data-start=\"2523\" data-end=\"2552\"\u003eIndustrial control panels\u003c\/li\u003e\n\u003cli data-section-id=\"1yybkbr\" data-start=\"2553\" data-end=\"2594\"\u003eCommercial power distribution systems\u003c\/li\u003e\n\u003cli data-section-id=\"x5ewh3\" data-start=\"2595\" data-end=\"2627\"\u003eSwitchboards and panelboards\u003c\/li\u003e\n\u003cli data-section-id=\"1wq9cqo\" data-start=\"2628\" data-end=\"2659\"\u003eOEM machinery and equipment\u003c\/li\u003e\n\u003cli data-section-id=\"m3tkrd\" data-start=\"2660\" data-end=\"2706\"\u003eMotor feeder and branch circuit protection\u003c\/li\u003e\n\u003cli data-section-id=\"bzayu1\" data-start=\"2707\" data-end=\"2752\"\u003eManufacturing and process control systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2754\" data-end=\"2757\"\u003e\n\u003ch3 data-section-id=\"1siptvj\" data-start=\"2759\" data-end=\"2789\"\u003eCertifications \u0026amp; Approvals\u003c\/h3\u003e\n\u003cul data-start=\"2791\" data-end=\"3005\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\n\u003cli data-section-id=\"1w9xzw2\" data-start=\"2791\" data-end=\"2804\"\u003eUL Listed\u003c\/li\u003e\n\u003cli data-section-id=\"breav2\" data-start=\"2805\" data-end=\"2822\"\u003eCSA Certified\u003c\/li\u003e\n\u003cli data-section-id=\"1nx0unc\" data-start=\"2823\" data-end=\"2840\"\u003eIEC Compliant\u003c\/li\u003e\n\u003cli data-section-id=\"n6bouy\" data-start=\"2841\" data-end=\"2854\"\u003eCE Marked\u003c\/li\u003e\n\u003cli data-section-id=\"1syfab3\" data-start=\"2855\" data-end=\"2871\"\u003eNOM Approved\u003c\/li\u003e\n\u003cli data-section-id=\"9jxruo\" data-start=\"2872\" data-end=\"2907\"\u003eMeets applicable NEMA standards\u003c\/li\u003e\n\u003cli data-section-id=\"16xj22m\" data-start=\"2908\" data-end=\"2959\"\u003eAuthentic Square D \/ Schneider Electric product\u003c\/li\u003e\n\u003cli data-section-id=\"gnpxfm\" data-start=\"2960\" data-end=\"3005\" data-is-last-node=\"\"\u003eDesigned for PowerPacT B-Frame applications\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Square D","offers":[{"title":"NEW","offer_id":48528519069945,"sku":"BDL36125","price":1270.35,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/BDL36015-New-1_aa571732-6a24-4de4-bf15-e835522850ec.webp?v=1781442030","url":"https:\/\/mycircuitbreakers.com\/products\/square-d-bdl36125-powerpact-b-frame-molded-case-circuit-breaker-3-pole-125a-600v-feed-thru-thermal-magnetic-li","provider":"My Circuit Breakers","version":"1.0","type":"link"}