{"product_id":"square-d-bgl36020-molded-case-circuit-breaker-powerpact-b-frame-3-pole-20a-600y-347vac-feed-thru-thermal-magnetic","title":"Square D BGL36020 Molded Case Circuit Breaker – PowerPacT B-Frame – 3 Pole – 20A – 600Y\/347VAC – Feed-Thru – Thermal Magnetic","description":"\u003cp data-start=\"147\" data-end=\"593\"\u003eThe Square D BGL36020 is a PowerPacT B-Frame molded case circuit breaker designed to provide dependable overcurrent and short-circuit protection in commercial, industrial, and OEM electrical distribution systems. Manufactured by Schneider Electric under the Square D brand, this 3-pole breaker combines compact dimensions, high interrupting capacity, and proven thermal-magnetic trip technology for reliable circuit protection.\u003c\/p\u003e\n\u003cp data-start=\"595\" data-end=\"1101\"\u003eRated at 20A and 600Y\/347VAC, the BGL36020 features fixed thermal-magnetic protection with long-time and instantaneous (LI) trip functions. Its feed-thru unit-mount construction supports both traditional back-pan mounting and integrated DIN rail installation, providing flexibility for new installations and retrofit projects. The breaker incorporates patented EverLink lug terminals on both line and load sides to help maintain secure conductor connections and reduce the effects of cable creep over time.\u003c\/p\u003e\n\u003cp data-start=\"1103\" data-end=\"1322\"\u003eWith a 35kA interrupting capacity at 480VAC and an 18kA breaking capacity at 600Y\/347VAC, this breaker is well suited for protecting three-phase distribution circuits in demanding commercial and industrial environments.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1yl5694\" data-start=\"1324\" data-end=\"1342\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-start=\"1344\" data-end=\"1809\"\u003e\n\u003cli data-section-id=\"xa05nv\" data-start=\"1344\" data-end=\"1361\"\u003eBrand: Square D\u003c\/li\u003e\n\u003cli data-section-id=\"i13y4o\" data-start=\"1362\" data-end=\"1396\"\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n\u003cli data-section-id=\"1w9tfa7\" data-start=\"1397\" data-end=\"1420\"\u003ePart Number: BGL36020\u003c\/li\u003e\n\u003cli data-section-id=\"uxyq11\" data-start=\"1421\" data-end=\"1448\"\u003eSeries: PowerPacT B-Frame\u003c\/li\u003e\n\u003cli data-section-id=\"vlzu7d\" data-start=\"1449\" data-end=\"1484\"\u003eType: Molded Case Circuit Breaker\u003c\/li\u003e\n\u003cli data-section-id=\"1ryzark\" data-start=\"1485\" data-end=\"1508\"\u003eConfiguration: 3 Pole\u003c\/li\u003e\n\u003cli data-section-id=\"wyns6e\" data-start=\"1509\" data-end=\"1525\"\u003ePhase: 3 Phase\u003c\/li\u003e\n\u003cli data-section-id=\"1ky69dk\" data-start=\"1526\" data-end=\"1547\"\u003eCurrent Rating: 20A\u003c\/li\u003e\n\u003cli data-section-id=\"1l83gl0\" data-start=\"1548\" data-end=\"1577\"\u003eVoltage Rating: 600Y\/347VAC\u003c\/li\u003e\n\u003cli data-section-id=\"p3pxsf\" data-start=\"1578\" data-end=\"1606\"\u003eConnection Type: Feed-Thru\u003c\/li\u003e\n\u003cli data-section-id=\"10zt8yb\" data-start=\"1607\" data-end=\"1652\"\u003eMounting Style: Unit Mount \/ DIN Rail Mount\u003c\/li\u003e\n\u003cli data-section-id=\"1jf49g9\" data-start=\"1653\" data-end=\"1688\"\u003eTrip Technology: Thermal Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"402970\" data-start=\"1689\" data-end=\"1739\"\u003eTrip Functions: LI – Long-Time and Instantaneous\u003c\/li\u003e\n\u003cli data-section-id=\"h0lcuu\" data-start=\"1740\" data-end=\"1775\"\u003eProtection Type: Thermal-Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"1csexap\" data-start=\"1776\" data-end=\"1809\"\u003eInterrupt Rating: 35kA @ 480VAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1v2p98c\" data-start=\"1811\" data-end=\"1833\"\u003eElectrical Ratings\u003c\/h3\u003e\n\u003cul data-start=\"1835\" data-end=\"2055\"\u003e\n\u003cli data-section-id=\"1ky69dk\" data-start=\"1835\" data-end=\"1856\"\u003eCurrent Rating: 20A\u003c\/li\u003e\n\u003cli data-section-id=\"1l83gl0\" data-start=\"1857\" data-end=\"1886\"\u003eVoltage Rating: 600Y\/347VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1ei0vya\" data-start=\"1887\" data-end=\"1925\"\u003eInterrupting Capacity: 35kA @ 480VAC\u003c\/li\u003e\n\u003cli data-section-id=\"bmixfd\" data-start=\"1926\" data-end=\"1965\"\u003eBreaking Capacity: 18kA @ 600Y\/347VAC\u003c\/li\u003e\n\u003cli data-section-id=\"11lbj23\" data-start=\"1966\" data-end=\"1998\"\u003eContinuous Current Rating: 80%\u003c\/li\u003e\n\u003cli data-section-id=\"xrvarm\" data-start=\"1999\" data-end=\"2055\"\u003eProtection Type: Overload and Short-Circuit Protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"bpec4l\" data-start=\"2057\" data-end=\"2071\"\u003eDimensions\u003c\/h3\u003e\n\u003cul data-start=\"2073\" data-end=\"2142\"\u003e\n\u003cli data-section-id=\"i551to\" data-start=\"2073\" data-end=\"2090\"\u003eHeight: 5.39 in\u003c\/li\u003e\n\u003cli data-section-id=\"1phdmyp\" data-start=\"2091\" data-end=\"2107\"\u003eWidth: 3.19 in\u003c\/li\u003e\n\u003cli data-section-id=\"as6tuu\" data-start=\"2108\" data-end=\"2124\"\u003eDepth: 3.15 in\u003c\/li\u003e\n\u003cli data-section-id=\"1cdwirn\" data-start=\"2125\" data-end=\"2142\"\u003eWeight: 2.37 lb\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1uohfrv\" data-start=\"2144\" data-end=\"2160\"\u003eConstruction\u003c\/h3\u003e\n\u003cul data-start=\"2162\" data-end=\"2561\"\u003e\n\u003cli data-section-id=\"wll44x\" data-start=\"2162\" data-end=\"2196\"\u003eCompact PowerPacT B-Frame design\u003c\/li\u003e\n\u003cli data-section-id=\"1yxxyns\" data-start=\"2197\" data-end=\"2231\"\u003eFixed thermal-magnetic trip unit\u003c\/li\u003e\n\u003cli data-section-id=\"1t9yzql\" data-start=\"2232\" data-end=\"2293\"\u003eDual-break rotating contacts for reduced peak fault current\u003c\/li\u003e\n\u003cli data-section-id=\"t9vist\" data-start=\"2294\" data-end=\"2324\"\u003eIntegral push-to-trip button\u003c\/li\u003e\n\u003cli data-section-id=\"2770dc\" data-start=\"2325\" data-end=\"2360\"\u003eFeed-thru unit-mount construction\u003c\/li\u003e\n\u003cli data-section-id=\"1whuhio\" data-start=\"2361\" data-end=\"2403\"\u003eTraditional back-pan mounting capability\u003c\/li\u003e\n\u003cli data-section-id=\"5mynoj\" data-start=\"2404\" data-end=\"2441\"\u003eIntegrated DIN rail mounting option\u003c\/li\u003e\n\u003cli data-section-id=\"1jbxlyg\" data-start=\"2442\" data-end=\"2489\"\u003eEverLink lug terminals on line and load sides\u003c\/li\u003e\n\u003cli data-section-id=\"745dy9\" data-start=\"2490\" data-end=\"2526\"\u003eNon-interchangeable trip mechanism\u003c\/li\u003e\n\u003cli data-section-id=\"1v8863o\" data-start=\"2527\" data-end=\"2561\"\u003eDurable molded case construction\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"wggvqn\" data-start=\"2563\" data-end=\"2579\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"2581\" data-end=\"2835\"\u003e\n\u003cli data-section-id=\"wmvwwh\" data-start=\"2581\" data-end=\"2625\"\u003eCommercial electrical distribution systems\u003c\/li\u003e\n\u003cli data-section-id=\"10c95fu\" data-start=\"2626\" data-end=\"2653\"\u003eIndustrial control panels\u003c\/li\u003e\n\u003cli data-section-id=\"1l89orm\" data-start=\"2654\" data-end=\"2669\"\u003eOEM equipment\u003c\/li\u003e\n\u003cli data-section-id=\"1n6ka4s\" data-start=\"2670\" data-end=\"2696\"\u003eManufacturing facilities\u003c\/li\u003e\n\u003cli data-section-id=\"zbnhog\" data-start=\"2697\" data-end=\"2727\"\u003eSwitchboards and panelboards\u003c\/li\u003e\n\u003cli data-section-id=\"1tbszxj\" data-start=\"2728\" data-end=\"2767\"\u003eThree-phase branch circuit protection\u003c\/li\u003e\n\u003cli data-section-id=\"ecya04\" data-start=\"2768\" data-end=\"2798\"\u003eMachinery power distribution\u003c\/li\u003e\n\u003cli data-section-id=\"1p540kw\" data-start=\"2799\" data-end=\"2835\"\u003eBuilding electrical infrastructure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1siptvj\" data-start=\"2837\" data-end=\"2867\"\u003eCertifications \u0026amp; Approvals\u003c\/h3\u003e\n\u003cul data-start=\"2869\" data-end=\"3035\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\n\u003cli data-section-id=\"jgz3lh\" data-start=\"2869\" data-end=\"2880\"\u003eUL Listed\u003c\/li\u003e\n\u003cli data-section-id=\"16shjxx\" data-start=\"2881\" data-end=\"2895\"\u003eCSA Approved\u003c\/li\u003e\n\u003cli data-section-id=\"nu2skv\" data-start=\"2896\" data-end=\"2911\"\u003eIEC Compliant\u003c\/li\u003e\n\u003cli data-section-id=\"8y7uuk\" data-start=\"2912\" data-end=\"2927\"\u003eNOM Compliant\u003c\/li\u003e\n\u003cli data-section-id=\"20b5ct\" data-start=\"2928\" data-end=\"2939\"\u003eCE Marked\u003c\/li\u003e\n\u003cli data-section-id=\"1d2xvdl\" data-start=\"2940\" data-end=\"2989\"\u003eAuthentic Square D \/ Schneider Electric Product\u003c\/li\u003e\n\u003cli data-section-id=\"793o2t\" data-start=\"2990\" data-end=\"3035\" data-is-last-node=\"\"\u003eDesigned for PowerPacT B-Frame Applications\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Square D","offers":[{"title":"NEW","offer_id":48528521167097,"sku":"BGL36020","price":907.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/BGL36015-New-1_4b39751b-def3-4bc3-808a-c06db1d0bec1.webp?v=1781442959","url":"https:\/\/mycircuitbreakers.com\/products\/square-d-bgl36020-molded-case-circuit-breaker-powerpact-b-frame-3-pole-20a-600y-347vac-feed-thru-thermal-magnetic","provider":"My Circuit Breakers","version":"1.0","type":"link"}