{"product_id":"square-d-edb14030epd-molded-case-circuit-breaker-1-pole-30a-277vac-bolt-on-e-frame-thermal-magnetic-equipment-protection-device","title":"Square D EDB14030EPD Molded Case Circuit Breaker – 1 Pole – 30A – 277VAC – Bolt-On – E-Frame – Thermal Magnetic – Equipment Protection Device","description":"\u003cp data-start=\"337\" data-end=\"630\"\u003eThe Square D EDB14030EPD, manufactured by Schneider Electric, is a bolt-on molded case circuit breaker designed for use in Square D NF panelboards. It belongs to the EDB Series E-Frame platform and provides reliable thermal-magnetic protection for commercial and industrial electrical systems.\u003c\/p\u003e\n\u003cp data-start=\"632\" data-end=\"934\"\u003eThis 1-pole, 30A breaker is rated for 277VAC applications and is equipped with an Equipment Protection Device (EPD) feature, enhancing system safety in sensitive load environments. The breaker uses a fixed thermal and magnetic trip mechanism to deliver dependable short-circuit and overload protection.\u003c\/p\u003e\n\u003cp data-start=\"936\" data-end=\"1197\"\u003eDesigned for easy installation, the bolt-on connection ensures secure mounting in compatible NF panelboards. Its compact construction, high interrupting capacity, and HACR\/HID ratings make it suitable for lighting, HVAC, and general power distribution circuits.\u003c\/p\u003e\n\u003ch2 data-section-id=\"6lgrrl\" data-start=\"1204\" data-end=\"1226\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1207\" data-end=\"1226\"\u003eSpecifications:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-start=\"1228\" data-end=\"1886\"\u003e\n\u003cli data-section-id=\"lpdqlo\" data-start=\"1228\" data-end=\"1251\"\u003e\n\u003cstrong data-start=\"1230\" data-end=\"1240\"\u003eBrand:\u003c\/strong\u003e Square D\u003c\/li\u003e\n\u003cli data-section-id=\"dn3u0f\" data-start=\"1252\" data-end=\"1292\"\u003e\n\u003cstrong data-start=\"1254\" data-end=\"1271\"\u003eManufacturer:\u003c\/strong\u003e Schneider Electric\u003c\/li\u003e\n\u003cli data-section-id=\"18ydl42\" data-start=\"1293\" data-end=\"1325\"\u003e\n\u003cstrong data-start=\"1295\" data-end=\"1311\"\u003ePart Number:\u003c\/strong\u003e EDB14030EPD\u003c\/li\u003e\n\u003cli data-section-id=\"ijf4q2\" data-start=\"1326\" data-end=\"1345\"\u003e\n\u003cstrong data-start=\"1328\" data-end=\"1339\"\u003eSeries:\u003c\/strong\u003e EDB\u003c\/li\u003e\n\u003cli data-section-id=\"1r943un\" data-start=\"1346\" data-end=\"1367\"\u003e\n\u003cstrong data-start=\"1348\" data-end=\"1357\"\u003eType:\u003c\/strong\u003e E-Frame\u003c\/li\u003e\n\u003cli data-section-id=\"1smzwo6\" data-start=\"1368\" data-end=\"1413\"\u003e\n\u003cstrong data-start=\"1370\" data-end=\"1383\"\u003eCategory:\u003c\/strong\u003e Molded Case Circuit Breaker\u003c\/li\u003e\n\u003cli data-section-id=\"1l38xqd\" data-start=\"1414\" data-end=\"1443\"\u003e\n\u003cstrong data-start=\"1416\" data-end=\"1434\"\u003eConfiguration:\u003c\/strong\u003e 1 Pole\u003c\/li\u003e\n\u003cli data-section-id=\"1waosar\" data-start=\"1444\" data-end=\"1466\"\u003e\n\u003cstrong data-start=\"1446\" data-end=\"1456\"\u003ePhase:\u003c\/strong\u003e 1 Phase\u003c\/li\u003e\n\u003cli data-section-id=\"1me4yym\" data-start=\"1467\" data-end=\"1494\"\u003e\n\u003cstrong data-start=\"1469\" data-end=\"1488\"\u003eCurrent Rating:\u003c\/strong\u003e 30A\u003c\/li\u003e\n\u003cli data-section-id=\"1vwkuq9\" data-start=\"1495\" data-end=\"1525\"\u003e\n\u003cstrong data-start=\"1497\" data-end=\"1516\"\u003eVoltage Rating:\u003c\/strong\u003e 277VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1wcfe6p\" data-start=\"1526\" data-end=\"1557\"\u003e\n\u003cstrong data-start=\"1528\" data-end=\"1547\"\u003eMounting Style:\u003c\/strong\u003e Bolt-On\u003c\/li\u003e\n\u003cli data-section-id=\"s9au6\" data-start=\"1558\" data-end=\"1599\"\u003e\n\u003cstrong data-start=\"1560\" data-end=\"1580\"\u003eTrip Technology:\u003c\/strong\u003e Thermal Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"1fo5n9m\" data-start=\"1600\" data-end=\"1655\"\u003e\n\u003cstrong data-start=\"1602\" data-end=\"1620\"\u003eTrip Function:\u003c\/strong\u003e Long-Time and Instantaneous (LI)\u003c\/li\u003e\n\u003cli data-section-id=\"1kmhj46\" data-start=\"1656\" data-end=\"1707\"\u003e\n\u003cstrong data-start=\"1658\" data-end=\"1678\"\u003eProtection Type:\u003c\/strong\u003e Overload and Short-Circuit\u003c\/li\u003e\n\u003cli data-section-id=\"1qcvvgc\" data-start=\"1708\" data-end=\"1754\"\u003e\n\u003cstrong data-start=\"1710\" data-end=\"1742\"\u003eEquipment Protection Device:\u003c\/strong\u003e Yes (EPD)\u003c\/li\u003e\n\u003cli data-section-id=\"j2cw88\" data-start=\"1755\" data-end=\"1797\"\u003e\n\u003cstrong data-start=\"1757\" data-end=\"1783\"\u003eInterrupting Capacity:\u003c\/strong\u003e 18kA @ 480V\u003c\/li\u003e\n\u003cli data-section-id=\"1xt4hbx\" data-start=\"1798\" data-end=\"1848\"\u003e\n\u003cstrong data-start=\"1800\" data-end=\"1823\"\u003eApplication Rating:\u003c\/strong\u003e HID-Rated \/ HACR-Rated\u003c\/li\u003e\n\u003cli data-section-id=\"1c608v7\" data-start=\"1849\" data-end=\"1886\"\u003e\n\u003cstrong data-start=\"1851\" data-end=\"1879\"\u003eCalibration Temperature:\u003c\/strong\u003e 40°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"1utx5c5\" data-start=\"1893\" data-end=\"1922\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1896\" data-end=\"1922\"\u003eConstruction Features:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-start=\"1924\" data-end=\"2316\"\u003e\n\u003cli data-section-id=\"1itvxl6\" data-start=\"1924\" data-end=\"1970\"\u003eBolt-on design for Square D NF panelboards\u003c\/li\u003e\n\u003cli data-section-id=\"1yushuv\" data-start=\"1971\" data-end=\"2003\"\u003eCompact E-Frame construction\u003c\/li\u003e\n\u003cli data-section-id=\"1dvznuk\" data-start=\"2004\" data-end=\"2042\"\u003eThermal-magnetic fixed trip system\u003c\/li\u003e\n\u003cli data-section-id=\"1lf7d0l\" data-start=\"2043\" data-end=\"2089\"\u003eBuilt-in Equipment Protection Device (EPD)\u003c\/li\u003e\n\u003cli data-section-id=\"s0wbfx\" data-start=\"2090\" data-end=\"2151\"\u003eVisual trip indication (where applicable in EDB platform)\u003c\/li\u003e\n\u003cli data-section-id=\"sqmrsf\" data-start=\"2152\" data-end=\"2186\"\u003eAluminum lug connection system\u003c\/li\u003e\n\u003cli data-section-id=\"o1mb23\" data-start=\"2187\" data-end=\"2259\"\u003eDesigned for consistent performance in commercial electrical systems\u003c\/li\u003e\n\u003cli data-section-id=\"17p8pzj\" data-start=\"2260\" data-end=\"2316\"\u003eFactory-calibrated for standard operating conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"lmmed2\" data-start=\"2323\" data-end=\"2343\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"2326\" data-end=\"2343\"\u003eApplications:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-start=\"2345\" data-end=\"2559\"\u003e\n\u003cli data-section-id=\"ui5zcs\" data-start=\"2345\" data-end=\"2376\"\u003eCommercial lighting systems\u003c\/li\u003e\n\u003cli data-section-id=\"k3iwfq\" data-start=\"2377\" data-end=\"2415\"\u003eHVAC and air conditioning circuits\u003c\/li\u003e\n\u003cli data-section-id=\"1b935sd\" data-start=\"2416\" data-end=\"2445\"\u003eIndustrial control panels\u003c\/li\u003e\n\u003cli data-section-id=\"1xsibhs\" data-start=\"2446\" data-end=\"2481\"\u003eMotor and compressor protection\u003c\/li\u003e\n\u003cli data-section-id=\"1ok1nje\" data-start=\"2482\" data-end=\"2518\"\u003eBuilding electrical distribution\u003c\/li\u003e\n\u003cli data-section-id=\"1lbbq9y\" data-start=\"2519\" data-end=\"2559\"\u003eSquare D NF panelboard installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"dx01xh\" data-start=\"2566\" data-end=\"2595\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"2569\" data-end=\"2595\"\u003eStandards \u0026amp; Approvals:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-start=\"2597\" data-end=\"2746\"\u003e\n\u003cli data-section-id=\"13dr6db\" data-start=\"2597\" data-end=\"2619\"\u003eUL Listed (UL 489)\u003c\/li\u003e\n\u003cli data-section-id=\"breav2\" data-start=\"2620\" data-end=\"2637\"\u003eCSA Certified\u003c\/li\u003e\n\u003cli data-section-id=\"k2kph2\" data-start=\"2638\" data-end=\"2652\"\u003eHACR Rated\u003c\/li\u003e\n\u003cli data-section-id=\"oqrasr\" data-start=\"2653\" data-end=\"2666\"\u003eHID Rated\u003c\/li\u003e\n\u003cli data-section-id=\"1sltslk\" data-start=\"2667\" data-end=\"2699\"\u003eNEMA \/ ANSI compliant design\u003c\/li\u003e\n\u003cli data-section-id=\"1xrtovl\" data-start=\"2700\" data-end=\"2746\"\u003eSuitable for industrial and commercial use\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Square D","offers":[{"title":"NEW","offer_id":48529085890809,"sku":"EDB14030EPD","price":691.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/30_43276bba-6e68-4190-a8a1-a290457ad20f.webp?v=1781456521","url":"https:\/\/mycircuitbreakers.com\/products\/square-d-edb14030epd-molded-case-circuit-breaker-1-pole-30a-277vac-bolt-on-e-frame-thermal-magnetic-equipment-protection-device","provider":"My Circuit Breakers","version":"1.0","type":"link"}