{"product_id":"square-d-edb24100sa-e-frame-molded-case-circuit-breaker-2-pole-100a-bolt-on-thermal-magnetic-120vac-shunt-trip","title":"Square D EDB24100SA E-Frame Molded Case Circuit Breaker – 2 Pole – 100A – Bolt-On – Thermal Magnetic – 120VAC Shunt Trip","description":"\u003cp data-start=\"171\" data-end=\"600\"\u003eThe \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eSquare D\u003c\/span\u003e\u003c\/span\u003e EDB24100SA is a molded case circuit breaker engineered for commercial and industrial electrical distribution systems requiring remote tripping capability. Manufactured by \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eSchneider Electric\u003c\/span\u003e\u003c\/span\u003e, this 2-pole, 100A breaker features a factory-installed 120VAC shunt trip that enables remote circuit disconnection for enhanced control and safety applications.\u003c\/p\u003e\n\u003cp data-start=\"602\" data-end=\"989\"\u003eDesigned for installation in NF panelboards, the EDB24100SA utilizes a bolt-on mounting configuration and requires three panelboard pole spaces due to the integrated shunt trip accessory. The breaker provides dependable thermal-magnetic protection with fixed long-time and instantaneous trip characteristics, helping protect electrical systems from overload and short-circuit conditions.\u003c\/p\u003e\n\u003cp data-start=\"991\" data-end=\"1278\"\u003eA built-in Visi-Trip indicator allows rapid identification of tripped circuits, reducing troubleshooting time and simplifying maintenance. With interrupting ratings up to 25kA at 240VAC, this breaker is well suited for demanding commercial and industrial power distribution applications.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1yl5694\" data-start=\"1280\" data-end=\"1298\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-start=\"1300\" data-end=\"1878\"\u003e\n\u003cli data-section-id=\"lbkw4z\" data-start=\"1300\" data-end=\"1348\"\u003eBrand: \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eSquare D\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1puzkdb\" data-start=\"1349\" data-end=\"1404\"\u003eManufacturer: \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eSchneider Electric\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"dri5fr\" data-start=\"1405\" data-end=\"1432\"\u003ePart Number: EDB24100SA\u003c\/li\u003e\n\u003cli data-section-id=\"ja1v2u\" data-start=\"1433\" data-end=\"1455\"\u003eSeries: EDB Series\u003c\/li\u003e\n\u003cli data-section-id=\"1azvqu5\" data-start=\"1456\" data-end=\"1503\"\u003eType: Molded Case Circuit Breaker (E-Frame)\u003c\/li\u003e\n\u003cli data-section-id=\"utf2jl\" data-start=\"1504\" data-end=\"1529\"\u003eConfiguration: 2 Pole\u003c\/li\u003e\n\u003cli data-section-id=\"vdhrok\" data-start=\"1530\" data-end=\"1548\"\u003ePhase: 1 Phase\u003c\/li\u003e\n\u003cli data-section-id=\"19gbtl7\" data-start=\"1549\" data-end=\"1573\"\u003eCurrent Rating: 100A\u003c\/li\u003e\n\u003cli data-section-id=\"n19s5d\" data-start=\"1574\" data-end=\"1641\"\u003eVoltage Rating: 120VAC, 240VAC, 277VAC, 480Y\/277VAC, 120\/240VAC\u003c\/li\u003e\n\u003cli data-section-id=\"sybr12\" data-start=\"1642\" data-end=\"1669\"\u003eMounting Style: Bolt-On\u003c\/li\u003e\n\u003cli data-section-id=\"82sw01\" data-start=\"1670\" data-end=\"1703\"\u003eConnection Type: Lug Terminal\u003c\/li\u003e\n\u003cli data-section-id=\"1vwficb\" data-start=\"1704\" data-end=\"1741\"\u003eProtection Type: Thermal Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"1i6wvgf\" data-start=\"1742\" data-end=\"1793\"\u003eTrip Function: LI – Long-Time and Instantaneous\u003c\/li\u003e\n\u003cli data-section-id=\"nrtnak\" data-start=\"1794\" data-end=\"1847\"\u003eTrip Adjustability: Fixed Thermal, Fixed Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"1xg67qj\" data-start=\"1848\" data-end=\"1878\"\u003eApplication: NF Panelboard\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1oyz3ud\" data-start=\"1880\" data-end=\"1904\"\u003eInterrupting Ratings\u003c\/h3\u003e\n\u003cul data-start=\"1906\" data-end=\"2004\"\u003e\n\u003cli data-section-id=\"n1yj6t\" data-start=\"1906\" data-end=\"1923\"\u003e25kA @ 120VAC\u003c\/li\u003e\n\u003cli data-section-id=\"82do00\" data-start=\"1924\" data-end=\"1941\"\u003e25kA @ 240VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1iy4ayy\" data-start=\"1942\" data-end=\"1959\"\u003e18kA @ 277VAC\u003c\/li\u003e\n\u003cli data-section-id=\"10vusf4\" data-start=\"1960\" data-end=\"1982\"\u003e18kA @ 480Y\/277VAC\u003c\/li\u003e\n\u003cli data-section-id=\"9kptdo\" data-start=\"1983\" data-end=\"2004\"\u003e25kA @ 120\/240VAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1j9na6a\" data-start=\"2006\" data-end=\"2042\"\u003eElectrical \u0026amp; Mechanical Features\u003c\/h3\u003e\n\u003cul data-start=\"2044\" data-end=\"2497\"\u003e\n\u003cli data-section-id=\"1o0lkv2\" data-start=\"2044\" data-end=\"2116\"\u003eFactory-installed 120VAC shunt trip for remote circuit disconnection\u003c\/li\u003e\n\u003cli data-section-id=\"1ogmosi\" data-start=\"2117\" data-end=\"2189\"\u003eRequires three NF panelboard pole spaces due to integrated accessory\u003c\/li\u003e\n\u003cli data-section-id=\"a6gu9s\" data-start=\"2190\" data-end=\"2263\"\u003eThermal-magnetic protection for overload and short-circuit conditions\u003c\/li\u003e\n\u003cli data-section-id=\"18evsom\" data-start=\"2264\" data-end=\"2315\"\u003eFixed thermal and magnetic trip characteristics\u003c\/li\u003e\n\u003cli data-section-id=\"16hwo0c\" data-start=\"2316\" data-end=\"2382\"\u003eVisi-Trip visual trip indicator for quick fault identification\u003c\/li\u003e\n\u003cli data-section-id=\"xhpcjv\" data-start=\"2383\" data-end=\"2427\"\u003eBolt-on mounting for secure installation\u003c\/li\u003e\n\u003cli data-section-id=\"glzf7w\" data-start=\"2428\" data-end=\"2455\"\u003eHACR rated construction\u003c\/li\u003e\n\u003cli data-section-id=\"1714wzi\" data-start=\"2456\" data-end=\"2497\"\u003eRated for 40°C operating environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"luma9c\" data-start=\"2499\" data-end=\"2513\"\u003eWire Range\u003c\/h3\u003e\n\u003cul data-start=\"2515\" data-end=\"2648\"\u003e\n\u003cli data-section-id=\"1nvzmro\" data-start=\"2515\" data-end=\"2537\"\u003eCopper: AWG 14–2\/0\u003c\/li\u003e\n\u003cli data-section-id=\"13iogpf\" data-start=\"2538\" data-end=\"2562\"\u003eAluminum: AWG 12–2\/0\u003c\/li\u003e\n\u003cli data-section-id=\"hpb85p\" data-start=\"2563\" data-end=\"2593\"\u003eMaximum wire size: 2\/0 AWG\u003c\/li\u003e\n\u003cli data-section-id=\"s4iz07\" data-start=\"2594\" data-end=\"2648\"\u003eMinimum wire size: AWG 14 Copper \/ AWG 12 Aluminum\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"nrk6gw\" data-start=\"2650\" data-end=\"2665\"\u003eAccessories\u003c\/h3\u003e\n\u003cul data-start=\"2667\" data-end=\"2821\"\u003e\n\u003cli data-section-id=\"1lgwh2y\" data-start=\"2667\" data-end=\"2706\"\u003eFactory-installed 120VAC shunt trip\u003c\/li\u003e\n\u003cli data-section-id=\"1h1kwoa\" data-start=\"2707\" data-end=\"2734\"\u003eLoad-side lugs included\u003c\/li\u003e\n\u003cli data-section-id=\"1wy94og\" data-start=\"2735\" data-end=\"2761\"\u003eAluminum lugs included\u003c\/li\u003e\n\u003cli data-section-id=\"2pnpkb\" data-start=\"2762\" data-end=\"2791\"\u003ePadlock attachment option\u003c\/li\u003e\n\u003cli data-section-id=\"1v96dq\" data-start=\"2792\" data-end=\"2821\"\u003eLug kit options available\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"131luvw\" data-start=\"2823\" data-end=\"2848\"\u003eStandards \u0026amp; Approvals\u003c\/h3\u003e\n\u003cul data-start=\"2850\" data-end=\"3129\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\n\u003cli data-section-id=\"fjdscg\" data-start=\"2850\" data-end=\"2867\"\u003eUL 489 Listed\u003c\/li\u003e\n\u003cli data-section-id=\"1kuinwb\" data-start=\"2868\" data-end=\"2887\"\u003eCSA C22.2 No. 5\u003c\/li\u003e\n\u003cli data-section-id=\"1k7op58\" data-start=\"2888\" data-end=\"2913\"\u003eIEC 60947-2 Compliant\u003c\/li\u003e\n\u003cli data-section-id=\"1eatwje\" data-start=\"2914\" data-end=\"2927\"\u003eNEMA AB 1\u003c\/li\u003e\n\u003cli data-section-id=\"3h4a0l\" data-start=\"2928\" data-end=\"2944\"\u003eCSA Approved\u003c\/li\u003e\n\u003cli data-section-id=\"1gov7qo\" data-start=\"2945\" data-end=\"2961\"\u003ecULus Listed\u003c\/li\u003e\n\u003cli data-section-id=\"1l7p494\" data-start=\"2962\" data-end=\"2978\"\u003eNOM Approved\u003c\/li\u003e\n\u003cli data-section-id=\"11a7gqd\" data-start=\"2979\" data-end=\"2992\"\u003eUL Listed\u003c\/li\u003e\n\u003cli data-section-id=\"1fan452\" data-start=\"2993\" data-end=\"3092\"\u003eAuthentic \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eSquare D\u003c\/span\u003e\u003c\/span\u003e \/ \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eSchneider Electric\u003c\/span\u003e\u003c\/span\u003e product\u003c\/li\u003e\n\u003cli data-section-id=\"1z5i5x\" data-start=\"3093\" data-end=\"3129\" data-is-last-node=\"\"\u003eDesigned for NF Panelboard systems\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Square D","offers":[{"title":"NEW","offer_id":48529320739065,"sku":"EDB24100SA","price":1078.65,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/EDB24020-2-Pole-Circuit-Breaker_SquareD_1_0c4c7433-846c-4adc-af08-41af3cc86873.webp?v=1781459992","url":"https:\/\/mycircuitbreakers.com\/products\/square-d-edb24100sa-e-frame-molded-case-circuit-breaker-2-pole-100a-bolt-on-thermal-magnetic-120vac-shunt-trip","provider":"My Circuit Breakers","version":"1.0","type":"link"}