{"product_id":"square-d-edb34020sa-e-frame-molded-case-circuit-breaker-3-pole-20a-480v-bolt-on-thermal-magnetic-120v-shunt-trip","title":"Square D EDB34020SA E-Frame Molded Case Circuit Breaker – 3 Pole – 20A – 480V – Bolt-On – Thermal Magnetic – 120V Shunt Trip","description":"\u003cp data-start=\"177\" data-end=\"568\"\u003eThe \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eSquare D\u003c\/span\u003e\u003c\/span\u003e EDB34020SA is a 3-pole molded case circuit breaker designed for commercial and industrial power distribution applications. Manufactured by \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eSchneider Electric\u003c\/span\u003e\u003c\/span\u003e, this EDB Series breaker provides dependable thermal-magnetic protection against overload and short-circuit conditions in three-phase electrical systems.\u003c\/p\u003e\n\u003cp data-start=\"570\" data-end=\"878\"\u003eEngineered with a bolt-on mounting configuration, the EDB34020SA is suitable for installation in compatible panelboards and distribution equipment. The breaker features a factory-installed 120V shunt trip, allowing remote tripping capability for enhanced safety, emergency shutdown, and control applications.\u003c\/p\u003e\n\u003cp data-start=\"880\" data-end=\"1189\"\u003eWith a standard interrupting capacity of 18kA at 480V and fixed long-time and instantaneous trip functions, this breaker delivers reliable circuit protection while maintaining a compact E-Frame footprint. Its rugged molded case construction makes it ideal for demanding industrial and commercial environments.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1yl5694\" data-start=\"1191\" data-end=\"1209\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-start=\"1211\" data-end=\"1663\"\u003e\n\u003cli data-section-id=\"lbkw4z\" data-start=\"1211\" data-end=\"1259\"\u003eBrand: \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eSquare D\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1puzkdb\" data-start=\"1260\" data-end=\"1315\"\u003eManufacturer: \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eSchneider Electric\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ul4vyd\" data-start=\"1316\" data-end=\"1343\"\u003ePart Number: EDB34020SA\u003c\/li\u003e\n\u003cli data-section-id=\"ja1v2u\" data-start=\"1344\" data-end=\"1366\"\u003eSeries: EDB Series\u003c\/li\u003e\n\u003cli data-section-id=\"19em5gp\" data-start=\"1367\" data-end=\"1404\"\u003eType: Molded Case Circuit Breaker\u003c\/li\u003e\n\u003cli data-section-id=\"1ivewjk\" data-start=\"1405\" data-end=\"1430\"\u003eConfiguration: 3 Pole\u003c\/li\u003e\n\u003cli data-section-id=\"pvjmxy\" data-start=\"1431\" data-end=\"1449\"\u003ePhase: 3 Phase\u003c\/li\u003e\n\u003cli data-section-id=\"7s1ptk\" data-start=\"1450\" data-end=\"1473\"\u003eCurrent Rating: 20A\u003c\/li\u003e\n\u003cli data-section-id=\"7sa7z9\" data-start=\"1474\" data-end=\"1505\"\u003eVoltage Rating: 277\/480V AC\u003c\/li\u003e\n\u003cli data-section-id=\"1ibps6a\" data-start=\"1506\" data-end=\"1534\"\u003eConnection Type: Bolt-On\u003c\/li\u003e\n\u003cli data-section-id=\"1vwficb\" data-start=\"1535\" data-end=\"1572\"\u003eProtection Type: Thermal Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"1i6wvgf\" data-start=\"1573\" data-end=\"1624\"\u003eTrip Function: LI – Long-Time and Instantaneous\u003c\/li\u003e\n\u003cli data-section-id=\"19r2duc\" data-start=\"1625\" data-end=\"1663\"\u003eOperating Temperature Rating: 40°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1uf5u9y\" data-start=\"1665\" data-end=\"1688\"\u003eInterrupting Rating\u003c\/h3\u003e\n\u003cul data-start=\"1690\" data-end=\"1708\"\u003e\n\u003cli data-section-id=\"hvj9fo\" data-start=\"1690\" data-end=\"1708\"\u003e18kA @ 480V AC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"bpec4l\" data-start=\"1710\" data-end=\"1724\"\u003eDimensions\u003c\/h3\u003e\n\u003cul data-start=\"1726\" data-end=\"1801\"\u003e\n\u003cli data-section-id=\"8klmmu\" data-start=\"1726\" data-end=\"1745\"\u003eHeight: 5.66 in\u003c\/li\u003e\n\u003cli data-section-id=\"i2eu3m\" data-start=\"1746\" data-end=\"1764\"\u003eWidth: 3.92 in\u003c\/li\u003e\n\u003cli data-section-id=\"rqffds\" data-start=\"1765\" data-end=\"1783\"\u003eDepth: 4.05 in\u003c\/li\u003e\n\u003cli data-section-id=\"1q8t9vg\" data-start=\"1784\" data-end=\"1801\"\u003eWeight: 4 lbs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1j9na6a\" data-start=\"1803\" data-end=\"1839\"\u003eElectrical \u0026amp; Mechanical Features\u003c\/h3\u003e\n\u003cul data-start=\"1841\" data-end=\"2174\"\u003e\n\u003cli data-section-id=\"12mpqag\" data-start=\"1841\" data-end=\"1878\"\u003eFactory-installed 120V shunt trip\u003c\/li\u003e\n\u003cli data-section-id=\"1wogizv\" data-start=\"1879\" data-end=\"1913\"\u003eBolt-on mounting configuration\u003c\/li\u003e\n\u003cli data-section-id=\"1iy4p7f\" data-start=\"1914\" data-end=\"1972\"\u003eThermal-magnetic overload and short-circuit protection\u003c\/li\u003e\n\u003cli data-section-id=\"hljc2x\" data-start=\"1973\" data-end=\"2031\"\u003eFixed long-time and instantaneous trip characteristics\u003c\/li\u003e\n\u003cli data-section-id=\"bhonx1\" data-start=\"2032\" data-end=\"2073\"\u003eStandard interrupting capacity design\u003c\/li\u003e\n\u003cli data-section-id=\"gk884f\" data-start=\"2074\" data-end=\"2118\"\u003eCompact E-Frame molded case construction\u003c\/li\u003e\n\u003cli data-section-id=\"y8z7zu\" data-start=\"2119\" data-end=\"2174\"\u003eSuitable for three-phase power distribution systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"wggvqn\" data-start=\"2176\" data-end=\"2192\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"2194\" data-end=\"2454\"\u003e\n\u003cli data-section-id=\"ov2tsh\" data-start=\"2194\" data-end=\"2240\"\u003eCommercial electrical distribution systems\u003c\/li\u003e\n\u003cli data-section-id=\"132ucrr\" data-start=\"2241\" data-end=\"2284\"\u003eIndustrial power distribution equipment\u003c\/li\u003e\n\u003cli data-section-id=\"o2ie4s\" data-start=\"2285\" data-end=\"2332\"\u003eMotor control and branch circuit protection\u003c\/li\u003e\n\u003cli data-section-id=\"43f15k\" data-start=\"2333\" data-end=\"2363\"\u003eEmergency shutdown systems\u003c\/li\u003e\n\u003cli data-section-id=\"c8qt35\" data-start=\"2364\" data-end=\"2408\"\u003eRemote tripping and control applications\u003c\/li\u003e\n\u003cli data-section-id=\"1hn5tng\" data-start=\"2409\" data-end=\"2454\"\u003ePanelboards and switchboard installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"131luvw\" data-start=\"2456\" data-end=\"2481\"\u003eStandards \u0026amp; Approvals\u003c\/h3\u003e\n\u003cul data-start=\"2483\" data-end=\"2723\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\n\u003cli data-section-id=\"3h4a0l\" data-start=\"2483\" data-end=\"2499\"\u003eCSA Approved\u003c\/li\u003e\n\u003cli data-section-id=\"3dsv46\" data-start=\"2500\" data-end=\"2538\"\u003eThermal-Magnetic Protection Design\u003c\/li\u003e\n\u003cli data-section-id=\"14z7opt\" data-start=\"2539\" data-end=\"2579\"\u003eStandard Interrupting Capacity Rated\u003c\/li\u003e\n\u003cli data-section-id=\"1fan452\" data-start=\"2580\" data-end=\"2679\"\u003eAuthentic \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eSquare D\u003c\/span\u003e\u003c\/span\u003e \/ \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eSchneider Electric\u003c\/span\u003e\u003c\/span\u003e product\u003c\/li\u003e\n\u003cli data-section-id=\"s75u3n\" data-start=\"2680\" data-end=\"2723\" data-is-last-node=\"\"\u003eManufactured to EDB Series specifications\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Square D","offers":[{"title":"NEW","offer_id":48529327751417,"sku":"EDB34020SA","price":932.85,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/EDB34020SA-new-1.webp?v=1781460290","url":"https:\/\/mycircuitbreakers.com\/products\/square-d-edb34020sa-e-frame-molded-case-circuit-breaker-3-pole-20a-480v-bolt-on-thermal-magnetic-120v-shunt-trip","provider":"My Circuit Breakers","version":"1.0","type":"link"}