{"product_id":"square-d-egb24030sa-e-frame-molded-case-circuit-breaker-2-pole-30a-bolt-on-thermal-magnetic-120vac-shunt-trip","title":"Square D EGB24030SA E-Frame Molded Case Circuit Breaker – 2 Pole – 30A – Bolt-On – Thermal Magnetic – 120VAC Shunt Trip","description":"\u003cp data-start=\"172\" data-end=\"589\"\u003eThe \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eSquare D\u003c\/span\u003e\u003c\/span\u003e EGB24030SA is a molded case circuit breaker designed for applications requiring reliable protection with remote shutdown capability. Manufactured by \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eSchneider Electric\u003c\/span\u003e\u003c\/span\u003e, this 2-pole, 30A E-Frame breaker provides dependable thermal-magnetic protection for overloads and short-circuit faults in commercial and industrial electrical systems.\u003c\/p\u003e\n\u003cp data-start=\"591\" data-end=\"955\"\u003eThis model features a factory-installed 120VAC shunt trip, enabling remote tripping for emergency power-off systems, safety interlocks, and automated control applications. Designed for bolt-on installation, it mounts securely into NF panelboards and is compatible with systems requiring high interrupting capacity and reliable operation under demanding conditions.\u003c\/p\u003e\n\u003cp data-start=\"957\" data-end=\"1244\"\u003eWith a 35kA interrupting rating at 480Y\/277VAC and up to 65kA at lower voltages, the EGB24030SA delivers strong fault protection performance. It also includes a Visi-Trip indicator for quick visual identification of tripped circuits, helping reduce downtime and simplify troubleshooting.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1yl5694\" data-start=\"1246\" data-end=\"1264\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-start=\"1266\" data-end=\"1823\"\u003e\n\u003cli data-section-id=\"lbkw4z\" data-start=\"1266\" data-end=\"1314\"\u003eBrand: \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eSquare D\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1puzkdb\" data-start=\"1315\" data-end=\"1370\"\u003eManufacturer: \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eSchneider Electric\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"f0whba\" data-start=\"1371\" data-end=\"1398\"\u003ePart Number: EGB24030SA\u003c\/li\u003e\n\u003cli data-section-id=\"r6zqxh\" data-start=\"1399\" data-end=\"1421\"\u003eSeries: EGB Series\u003c\/li\u003e\n\u003cli data-section-id=\"1azvqu5\" data-start=\"1422\" data-end=\"1469\"\u003eType: Molded Case Circuit Breaker (E-Frame)\u003c\/li\u003e\n\u003cli data-section-id=\"utf2jl\" data-start=\"1470\" data-end=\"1495\"\u003eConfiguration: 2 Pole\u003c\/li\u003e\n\u003cli data-section-id=\"vdhrok\" data-start=\"1496\" data-end=\"1514\"\u003ePhase: 1 Phase\u003c\/li\u003e\n\u003cli data-section-id=\"7spoqh\" data-start=\"1515\" data-end=\"1538\"\u003eCurrent Rating: 30A\u003c\/li\u003e\n\u003cli data-section-id=\"js0jkp\" data-start=\"1539\" data-end=\"1586\"\u003eVoltage Rating: 120VAC, 240VAC, 480Y\/277VAC\u003c\/li\u003e\n\u003cli data-section-id=\"sybr12\" data-start=\"1587\" data-end=\"1614\"\u003eMounting Style: Bolt-On\u003c\/li\u003e\n\u003cli data-section-id=\"82sw01\" data-start=\"1615\" data-end=\"1648\"\u003eConnection Type: Lug Terminal\u003c\/li\u003e\n\u003cli data-section-id=\"1vwficb\" data-start=\"1649\" data-end=\"1686\"\u003eProtection Type: Thermal Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"1i6wvgf\" data-start=\"1687\" data-end=\"1738\"\u003eTrip Function: LI – Long-Time and Instantaneous\u003c\/li\u003e\n\u003cli data-section-id=\"nrtnak\" data-start=\"1739\" data-end=\"1792\"\u003eTrip Adjustability: Fixed Thermal, Fixed Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"1xg67qj\" data-start=\"1793\" data-end=\"1823\"\u003eApplication: NF Panelboard\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1oyz3ud\" data-start=\"1825\" data-end=\"1849\"\u003eInterrupting Ratings\u003c\/h3\u003e\n\u003cul data-start=\"1851\" data-end=\"1909\"\u003e\n\u003cli data-section-id=\"188cplt\" data-start=\"1851\" data-end=\"1868\"\u003e65kA @ 120VAC\u003c\/li\u003e\n\u003cli data-section-id=\"r1iv8\" data-start=\"1869\" data-end=\"1886\"\u003e65kA @ 240VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1hcd29b\" data-start=\"1887\" data-end=\"1909\"\u003e35kA @ 480Y\/277VAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1j9na6a\" data-start=\"1911\" data-end=\"1947\"\u003eElectrical \u0026amp; Mechanical Features\u003c\/h3\u003e\n\u003cul data-start=\"1949\" data-end=\"2359\"\u003e\n\u003cli data-section-id=\"mewekd\" data-start=\"1949\" data-end=\"2019\"\u003eFactory-installed 120VAC shunt trip for remote shutdown capability\u003c\/li\u003e\n\u003cli data-section-id=\"1iy4p7f\" data-start=\"2020\" data-end=\"2078\"\u003eThermal-magnetic overload and short-circuit protection\u003c\/li\u003e\n\u003cli data-section-id=\"1lnz5y2\" data-start=\"2079\" data-end=\"2129\"\u003eBolt-on mounting for NF panelboard integration\u003c\/li\u003e\n\u003cli data-section-id=\"1kyhqrr\" data-start=\"2130\" data-end=\"2166\"\u003eVisi-Trip visual fault indicator\u003c\/li\u003e\n\u003cli data-section-id=\"iw5l8i\" data-start=\"2167\" data-end=\"2202\"\u003eHACR and HID rated construction\u003c\/li\u003e\n\u003cli data-section-id=\"o8ix9\" data-start=\"2203\" data-end=\"2249\"\u003eOperating temperature range: -25°C to 70°C\u003c\/li\u003e\n\u003cli data-section-id=\"ncsc50\" data-start=\"2250\" data-end=\"2317\"\u003eSuitable for emergency power-off systems and automation control\u003c\/li\u003e\n\u003cli data-section-id=\"iidr4u\" data-start=\"2318\" data-end=\"2359\"\u003eNon-interchangeable fixed trip design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"luma9c\" data-start=\"2361\" data-end=\"2375\"\u003eWire Range\u003c\/h3\u003e\n\u003cul data-start=\"2377\" data-end=\"2504\"\u003e\n\u003cli data-section-id=\"5sm8u7\" data-start=\"2377\" data-end=\"2397\"\u003eCopper: AWG 14–6\u003c\/li\u003e\n\u003cli data-section-id=\"1xyhy08\" data-start=\"2398\" data-end=\"2420\"\u003eAluminum: AWG 12–6\u003c\/li\u003e\n\u003cli data-section-id=\"1l4hxfa\" data-start=\"2421\" data-end=\"2449\"\u003eMaximum wire size: AWG 6\u003c\/li\u003e\n\u003cli data-section-id=\"s4iz07\" data-start=\"2450\" data-end=\"2504\"\u003eMinimum wire size: AWG 14 Copper \/ AWG 12 Aluminum\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"nrk6gw\" data-start=\"2506\" data-end=\"2521\"\u003eAccessories\u003c\/h3\u003e\n\u003cul data-start=\"2523\" data-end=\"2644\"\u003e\n\u003cli data-section-id=\"1lgwh2y\" data-start=\"2523\" data-end=\"2562\"\u003eFactory-installed 120VAC shunt trip\u003c\/li\u003e\n\u003cli data-section-id=\"qfjc38\" data-start=\"2563\" data-end=\"2590\"\u003eAuxiliary switch option\u003c\/li\u003e\n\u003cli data-section-id=\"ygv3rh\" data-start=\"2591\" data-end=\"2614\"\u003eAlarm switch option\u003c\/li\u003e\n\u003cli data-section-id=\"2pnpkb\" data-start=\"2615\" data-end=\"2644\"\u003ePadlock attachment option\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"131luvw\" data-start=\"2646\" data-end=\"2671\"\u003eStandards \u0026amp; Approvals\u003c\/h3\u003e\n\u003cul data-start=\"2673\" data-end=\"2973\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\n\u003cli data-section-id=\"fjdscg\" data-start=\"2673\" data-end=\"2690\"\u003eUL 489 Listed\u003c\/li\u003e\n\u003cli data-section-id=\"1kuinwb\" data-start=\"2691\" data-end=\"2710\"\u003eCSA C22.2 No. 5\u003c\/li\u003e\n\u003cli data-section-id=\"czvth\" data-start=\"2711\" data-end=\"2734\"\u003eNEMA AB 1 Compliant\u003c\/li\u003e\n\u003cli data-section-id=\"1gfjlj2\" data-start=\"2735\" data-end=\"2756\"\u003eNFPA 70 Compliant\u003c\/li\u003e\n\u003cli data-section-id=\"3h4a0l\" data-start=\"2757\" data-end=\"2773\"\u003eCSA Approved\u003c\/li\u003e\n\u003cli data-section-id=\"1gov7qo\" data-start=\"2774\" data-end=\"2790\"\u003ecULus Listed\u003c\/li\u003e\n\u003cli data-section-id=\"1l7p494\" data-start=\"2791\" data-end=\"2807\"\u003eNOM Approved\u003c\/li\u003e\n\u003cli data-section-id=\"mq9pch\" data-start=\"2808\" data-end=\"2822\"\u003eHACR Rated\u003c\/li\u003e\n\u003cli data-section-id=\"1uyovzg\" data-start=\"2823\" data-end=\"2836\"\u003eHID Rated\u003c\/li\u003e\n\u003cli data-section-id=\"1fan452\" data-start=\"2837\" data-end=\"2936\"\u003eAuthentic \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eSquare D\u003c\/span\u003e\u003c\/span\u003e \/ \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eSchneider Electric\u003c\/span\u003e\u003c\/span\u003e product\u003c\/li\u003e\n\u003cli data-section-id=\"1z5i5x\" data-start=\"2937\" data-end=\"2973\" data-is-last-node=\"\"\u003eDesigned for NF Panelboard systems\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Square D","offers":[{"title":"NEW","offer_id":48529483596025,"sku":"EGB24030SA","price":868.05,"currency_code":"USD","in_stock":true}],"url":"https:\/\/mycircuitbreakers.com\/products\/square-d-egb24030sa-e-frame-molded-case-circuit-breaker-2-pole-30a-bolt-on-thermal-magnetic-120vac-shunt-trip","provider":"My Circuit Breakers","version":"1.0","type":"link"}