{"product_id":"square-d-egb24050sa-e-frame-molded-case-circuit-breaker-2-pole-50a-bolt-on-thermal-magnetic","title":"Square D EGB24050SA E-Frame Molded Case Circuit Breaker – 2 Pole – 50A – Bolt-On – Thermal Magnetic","description":"\u003cp data-start=\"152\" data-end=\"553\"\u003eThe \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eSquare D\u003c\/span\u003e\u003c\/span\u003e EGB24050SA is a molded case circuit breaker designed for commercial and industrial power distribution applications requiring reliable thermal-magnetic protection. Manufactured by \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eSchneider Electric\u003c\/span\u003e\u003c\/span\u003e, this 2-pole, 50A breaker is part of the EGB Series and is intended for use in NF panelboards with secure bolt-on mounting.\u003c\/p\u003e\n\u003cp data-start=\"555\" data-end=\"854\"\u003eThis E-Frame breaker delivers dependable overload and short-circuit protection using a fixed LI (Long-Time and Instantaneous) trip mechanism. Its compact design and high interrupting performance make it suitable for demanding electrical environments where system reliability and safety are critical.\u003c\/p\u003e\n\u003cp data-start=\"856\" data-end=\"1129\"\u003eThe EGB24050SA is commonly used in commercial buildings, industrial distribution systems, and OEM applications where consistent circuit protection is required. Its robust molded case construction ensures durability and long service life in challenging operating conditions.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1yl5694\" data-start=\"1131\" data-end=\"1149\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-start=\"1151\" data-end=\"1598\"\u003e\n\u003cli data-section-id=\"lbkw4z\" data-start=\"1151\" data-end=\"1199\"\u003eBrand: \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eSquare D\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1puzkdb\" data-start=\"1200\" data-end=\"1255\"\u003eManufacturer: \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eSchneider Electric\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"dqarts\" data-start=\"1256\" data-end=\"1283\"\u003ePart Number: EGB24050SA\u003c\/li\u003e\n\u003cli data-section-id=\"r6zqxh\" data-start=\"1284\" data-end=\"1306\"\u003eSeries: EGB Series\u003c\/li\u003e\n\u003cli data-section-id=\"6grwxl\" data-start=\"1307\" data-end=\"1332\"\u003eUNSPSC Code: 39120000\u003c\/li\u003e\n\u003cli data-section-id=\"1azvqu5\" data-start=\"1333\" data-end=\"1380\"\u003eType: Molded Case Circuit Breaker (E-Frame)\u003c\/li\u003e\n\u003cli data-section-id=\"utf2jl\" data-start=\"1381\" data-end=\"1406\"\u003eConfiguration: 2 Pole\u003c\/li\u003e\n\u003cli data-section-id=\"vdhrok\" data-start=\"1407\" data-end=\"1425\"\u003ePhase: 1 Phase\u003c\/li\u003e\n\u003cli data-section-id=\"7wy73z\" data-start=\"1426\" data-end=\"1449\"\u003eCurrent Rating: 50A\u003c\/li\u003e\n\u003cli data-section-id=\"sybr12\" data-start=\"1450\" data-end=\"1477\"\u003eMounting Style: Bolt-On\u003c\/li\u003e\n\u003cli data-section-id=\"1vwficb\" data-start=\"1478\" data-end=\"1515\"\u003eProtection Type: Thermal Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"1i6wvgf\" data-start=\"1516\" data-end=\"1567\"\u003eTrip Function: LI – Long-Time and Instantaneous\u003c\/li\u003e\n\u003cli data-section-id=\"1xg67qj\" data-start=\"1568\" data-end=\"1598\"\u003eApplication: NF Panelboard\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"i46vpi\" data-start=\"1600\" data-end=\"1630\"\u003eElectrical Characteristics\u003c\/h3\u003e\n\u003cul data-start=\"1632\" data-end=\"1856\"\u003e\n\u003cli data-section-id=\"7wy73z\" data-start=\"1632\" data-end=\"1655\"\u003eCurrent Rating: 50A\u003c\/li\u003e\n\u003cli data-section-id=\"1t83p25\" data-start=\"1656\" data-end=\"1771\"\u003eVoltage Rating: (typical EGB240 class systems) 120\/240VAC, 480Y\/277VAC compatibility depending on system design\u003c\/li\u003e\n\u003cli data-section-id=\"1hkrpot\" data-start=\"1772\" data-end=\"1856\"\u003eInterrupting Capacity: EGB Series high interrupting design (NF panelboard class)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"xldzoc\" data-start=\"1858\" data-end=\"1883\"\u003eConstruction Features\u003c\/h3\u003e\n\u003cul data-start=\"1885\" data-end=\"2140\"\u003e\n\u003cli data-section-id=\"37l920\" data-start=\"1885\" data-end=\"1921\"\u003eE-Frame molded case construction\u003c\/li\u003e\n\u003cli data-section-id=\"srh4fm\" data-start=\"1922\" data-end=\"1968\"\u003eBolt-on mounting system for NF panelboards\u003c\/li\u003e\n\u003cli data-section-id=\"5l4aem\" data-start=\"1969\" data-end=\"1999\"\u003eThermal-magnetic trip unit\u003c\/li\u003e\n\u003cli data-section-id=\"fk1gxn\" data-start=\"2000\" data-end=\"2048\"\u003eFixed long-time and instantaneous protection\u003c\/li\u003e\n\u003cli data-section-id=\"134o2kl\" data-start=\"2049\" data-end=\"2084\"\u003eCompact industrial-grade design\u003c\/li\u003e\n\u003cli data-section-id=\"1o219sv\" data-start=\"2085\" data-end=\"2140\"\u003eDesigned for reliability in high-fault environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"wggvqn\" data-start=\"2142\" data-end=\"2158\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"2160\" data-end=\"2353\"\u003e\n\u003cli data-section-id=\"ov2tsh\" data-start=\"2160\" data-end=\"2206\"\u003eCommercial electrical distribution systems\u003c\/li\u003e\n\u003cli data-section-id=\"h9pria\" data-start=\"2207\" data-end=\"2251\"\u003eIndustrial power panels and switchboards\u003c\/li\u003e\n\u003cli data-section-id=\"tdkmxw\" data-start=\"2252\" data-end=\"2283\"\u003eNF panelboard installations\u003c\/li\u003e\n\u003cli data-section-id=\"1br462v\" data-start=\"2284\" data-end=\"2315\"\u003eOEM machinery and equipment\u003c\/li\u003e\n\u003cli data-section-id=\"1smrk4d\" data-start=\"2316\" data-end=\"2353\"\u003eBranch circuit protection systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"ljc29o\" data-start=\"2355\" data-end=\"2378\"\u003eGeneral Information\u003c\/h3\u003e\n\u003cul data-start=\"2380\" data-end=\"2558\"\u003e\n\u003cli data-section-id=\"1mpiqk3\" data-start=\"2380\" data-end=\"2428\"\u003eBrand: \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eSquare D\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1etpxcv\" data-start=\"2429\" data-end=\"2484\"\u003eManufacturer: \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eSchneider Electric\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"131xqdi\" data-start=\"2485\" data-end=\"2508\"\u003eUnit of Measure: EA\u003c\/li\u003e\n\u003cli data-section-id=\"zwte3u\" data-start=\"2509\" data-end=\"2558\"\u003eProduct Category: Molded Case Circuit Breaker\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"nk5elx\" data-start=\"2560\" data-end=\"2586\"\u003eStandards \u0026amp; Compliance\u003c\/h3\u003e\n\u003cul data-start=\"2588\" data-end=\"2817\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\n\u003cli data-section-id=\"lg4uk5\" data-start=\"2588\" data-end=\"2626\"\u003eDesigned for NF Panelboard systems\u003c\/li\u003e\n\u003cli data-section-id=\"9ivnui\" data-start=\"2627\" data-end=\"2680\"\u003eIndustrial-grade molded case breaker construction\u003c\/li\u003e\n\u003cli data-section-id=\"terqv2\" data-start=\"2681\" data-end=\"2759\"\u003eManufactured under \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eSchneider Electric\u003c\/span\u003e\u003c\/span\u003e quality standards\u003c\/li\u003e\n\u003cli data-section-id=\"n6wbb8\" data-start=\"2760\" data-end=\"2817\" data-is-last-node=\"\"\u003eAuthentic \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eSquare D\u003c\/span\u003e\u003c\/span\u003e product\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Square D","offers":[{"title":"NEW","offer_id":48529504305401,"sku":"EGB24050SA","price":868.05,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/EDB24020-2-Pole-Circuit-Breaker_SquareD_1_6475bea7-4058-41da-af78-92f528dc1449.webp?v=1781463467","url":"https:\/\/mycircuitbreakers.com\/products\/square-d-egb24050sa-e-frame-molded-case-circuit-breaker-2-pole-50a-bolt-on-thermal-magnetic","provider":"My Circuit Breakers","version":"1.0","type":"link"}