{"product_id":"square-d-egb34060sa-e-frame-molded-case-circuit-breaker-3-pole-60a-bolt-on-thermal-magnetic-120vac-shunt-trip","title":"Square D EGB34060SA E-Frame Molded Case Circuit Breaker – 3 Pole – 60A – Bolt-On – Thermal Magnetic – 120VAC Shunt Trip","description":"\u003cp data-start=\"172\" data-end=\"625\"\u003eThe \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eSquare D\u003c\/span\u003e\u003c\/span\u003e EGB34060SA is a molded case circuit breaker designed for commercial and industrial power distribution systems requiring reliable protection with remote switching capability. Manufactured by \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eSchneider Electric\u003c\/span\u003e\u003c\/span\u003e, this 3-pole, 60A E-Frame breaker delivers dependable thermal-magnetic protection for overload and short-circuit conditions in three-phase electrical installations.\u003c\/p\u003e\n\u003cp data-start=\"627\" data-end=\"956\"\u003eThis model includes a factory-installed 120VAC shunt trip, allowing remote or automated circuit interruption for emergency shutdown systems, control integration, and facility safety applications. It mounts securely into NF panelboards using a bolt-on connection designed for stable, long-term operation in demanding environments.\u003c\/p\u003e\n\u003cp data-start=\"958\" data-end=\"1253\"\u003eWith a high interrupting rating of 65kA at 240VAC and 35kA at 480Y\/277VAC, the EGB34060SA provides strong fault protection performance suitable for commercial distribution systems. A Visi-Trip indicator enhances maintenance efficiency by enabling quick visual identification of tripped circuits.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1yl5694\" data-start=\"1255\" data-end=\"1273\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-start=\"1275\" data-end=\"1864\"\u003e\n\u003cli data-section-id=\"lbkw4z\" data-start=\"1275\" data-end=\"1323\"\u003eBrand: \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eSquare D\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1puzkdb\" data-start=\"1324\" data-end=\"1379\"\u003eManufacturer: \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eSchneider Electric\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"74w076\" data-start=\"1380\" data-end=\"1407\"\u003ePart Number: EGB34060SA\u003c\/li\u003e\n\u003cli data-section-id=\"r6zqxh\" data-start=\"1408\" data-end=\"1430\"\u003eSeries: EGB Series\u003c\/li\u003e\n\u003cli data-section-id=\"1azvqu5\" data-start=\"1431\" data-end=\"1478\"\u003eType: Molded Case Circuit Breaker (E-Frame)\u003c\/li\u003e\n\u003cli data-section-id=\"1ivewjk\" data-start=\"1479\" data-end=\"1504\"\u003eConfiguration: 3 Pole\u003c\/li\u003e\n\u003cli data-section-id=\"pvjmxy\" data-start=\"1505\" data-end=\"1523\"\u003ePhase: 3 Phase\u003c\/li\u003e\n\u003cli data-section-id=\"7uve2k\" data-start=\"1524\" data-end=\"1547\"\u003eCurrent Rating: 60A\u003c\/li\u003e\n\u003cli data-section-id=\"js0jkp\" data-start=\"1548\" data-end=\"1595\"\u003eVoltage Rating: 120VAC, 240VAC, 480Y\/277VAC\u003c\/li\u003e\n\u003cli data-section-id=\"sybr12\" data-start=\"1596\" data-end=\"1623\"\u003eMounting Style: Bolt-On\u003c\/li\u003e\n\u003cli data-section-id=\"82sw01\" data-start=\"1624\" data-end=\"1657\"\u003eConnection Type: Lug Terminal\u003c\/li\u003e\n\u003cli data-section-id=\"1vwficb\" data-start=\"1658\" data-end=\"1695\"\u003eProtection Type: Thermal Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"1i6wvgf\" data-start=\"1696\" data-end=\"1747\"\u003eTrip Function: LI – Long-Time and Instantaneous\u003c\/li\u003e\n\u003cli data-section-id=\"nrtnak\" data-start=\"1748\" data-end=\"1801\"\u003eTrip Adjustability: Fixed Thermal, Fixed Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"1vbx659\" data-start=\"1802\" data-end=\"1864\"\u003eApplication: NF Panelboard \/ Commercial Power Distribution\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1oyz3ud\" data-start=\"1866\" data-end=\"1890\"\u003eInterrupting Ratings\u003c\/h3\u003e\n\u003cul data-start=\"1892\" data-end=\"1950\"\u003e\n\u003cli data-section-id=\"188cplt\" data-start=\"1892\" data-end=\"1909\"\u003e65kA @ 120VAC\u003c\/li\u003e\n\u003cli data-section-id=\"r1iv8\" data-start=\"1910\" data-end=\"1927\"\u003e65kA @ 240VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1hcd29b\" data-start=\"1928\" data-end=\"1950\"\u003e35kA @ 480Y\/277VAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1j9na6a\" data-start=\"1952\" data-end=\"1988\"\u003eElectrical \u0026amp; Mechanical Features\u003c\/h3\u003e\n\u003cul data-start=\"1990\" data-end=\"2448\"\u003e\n\u003cli data-section-id=\"1ocm2f3\" data-start=\"1990\" data-end=\"2062\"\u003eFactory-installed 120VAC shunt trip for remote and automated control\u003c\/li\u003e\n\u003cli data-section-id=\"1iy4p7f\" data-start=\"2063\" data-end=\"2121\"\u003eThermal-magnetic overload and short-circuit protection\u003c\/li\u003e\n\u003cli data-section-id=\"1il62xm\" data-start=\"2122\" data-end=\"2163\"\u003eBolt-on NF panelboard mounting system\u003c\/li\u003e\n\u003cli data-section-id=\"1kyhqrr\" data-start=\"2164\" data-end=\"2200\"\u003eVisi-Trip visual fault indicator\u003c\/li\u003e\n\u003cli data-section-id=\"pn46iq\" data-start=\"2201\" data-end=\"2250\"\u003eHACR rated construction for HVAC applications\u003c\/li\u003e\n\u003cli data-section-id=\"fqivln\" data-start=\"2251\" data-end=\"2311\"\u003eDesigned for three-phase commercial distribution systems\u003c\/li\u003e\n\u003cli data-section-id=\"1llv3vs\" data-start=\"2312\" data-end=\"2380\"\u003eFixed trip characteristics for consistent protection performance\u003c\/li\u003e\n\u003cli data-section-id=\"1jhefpc\" data-start=\"2381\" data-end=\"2448\"\u003eSuitable for emergency shutdown and control integration systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"luma9c\" data-start=\"2450\" data-end=\"2464\"\u003eWire Range\u003c\/h3\u003e\n\u003cul data-start=\"2466\" data-end=\"2599\"\u003e\n\u003cli data-section-id=\"1nvzmro\" data-start=\"2466\" data-end=\"2488\"\u003eCopper: AWG 14–2\/0\u003c\/li\u003e\n\u003cli data-section-id=\"13iogpf\" data-start=\"2489\" data-end=\"2513\"\u003eAluminum: AWG 12–2\/0\u003c\/li\u003e\n\u003cli data-section-id=\"hpb85p\" data-start=\"2514\" data-end=\"2544\"\u003eMaximum wire size: 2\/0 AWG\u003c\/li\u003e\n\u003cli data-section-id=\"s4iz07\" data-start=\"2545\" data-end=\"2599\"\u003eMinimum wire size: AWG 14 Copper \/ AWG 12 Aluminum\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"nrk6gw\" data-start=\"2601\" data-end=\"2616\"\u003eAccessories\u003c\/h3\u003e\n\u003cul data-start=\"2618\" data-end=\"2739\"\u003e\n\u003cli data-section-id=\"1lgwh2y\" data-start=\"2618\" data-end=\"2657\"\u003eFactory-installed 120VAC shunt trip\u003c\/li\u003e\n\u003cli data-section-id=\"qfjc38\" data-start=\"2658\" data-end=\"2685\"\u003eAuxiliary switch option\u003c\/li\u003e\n\u003cli data-section-id=\"ygv3rh\" data-start=\"2686\" data-end=\"2709\"\u003eAlarm switch option\u003c\/li\u003e\n\u003cli data-section-id=\"2pnpkb\" data-start=\"2710\" data-end=\"2739\"\u003ePadlock attachment option\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"131luvw\" data-start=\"2741\" data-end=\"2766\"\u003eStandards \u0026amp; Approvals\u003c\/h3\u003e\n\u003cul data-start=\"2768\" data-end=\"3054\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\n\u003cli data-section-id=\"fjdscg\" data-start=\"2768\" data-end=\"2785\"\u003eUL 489 Listed\u003c\/li\u003e\n\u003cli data-section-id=\"1kuinwb\" data-start=\"2786\" data-end=\"2805\"\u003eCSA C22.2 No. 5\u003c\/li\u003e\n\u003cli data-section-id=\"1gfjlj2\" data-start=\"2806\" data-end=\"2827\"\u003eNFPA 70 Compliant\u003c\/li\u003e\n\u003cli data-section-id=\"czvth\" data-start=\"2828\" data-end=\"2851\"\u003eNEMA AB 1 Compliant\u003c\/li\u003e\n\u003cli data-section-id=\"3h4a0l\" data-start=\"2852\" data-end=\"2868\"\u003eCSA Approved\u003c\/li\u003e\n\u003cli data-section-id=\"1gov7qo\" data-start=\"2869\" data-end=\"2885\"\u003ecULus Listed\u003c\/li\u003e\n\u003cli data-section-id=\"mq9pch\" data-start=\"2886\" data-end=\"2900\"\u003eHACR Rated\u003c\/li\u003e\n\u003cli data-section-id=\"1l7p494\" data-start=\"2901\" data-end=\"2917\"\u003eNOM Approved\u003c\/li\u003e\n\u003cli data-section-id=\"1fan452\" data-start=\"2918\" data-end=\"3017\"\u003eAuthentic \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eSquare D\u003c\/span\u003e\u003c\/span\u003e \/ \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eSchneider Electric\u003c\/span\u003e\u003c\/span\u003e product\u003c\/li\u003e\n\u003cli data-section-id=\"1z5i5x\" data-start=\"3018\" data-end=\"3054\" data-is-last-node=\"\"\u003eDesigned for NF Panelboard systems\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Square D","offers":[{"title":"NEW","offer_id":48529579376889,"sku":"EGB34060SA","price":1377.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/EGB34050SA-3-Pole-Circuit-Breaker_SquareD_1_1024x_87513c1c-44be-40e5-b578-ceb914e3ccde.webp?v=1781464676","url":"https:\/\/mycircuitbreakers.com\/products\/square-d-egb34060sa-e-frame-molded-case-circuit-breaker-3-pole-60a-bolt-on-thermal-magnetic-120vac-shunt-trip","provider":"My Circuit Breakers","version":"1.0","type":"link"}