{"product_id":"square-d-ehb24015-bolt-on-molded-case-circuit-breaker-2-pole-15a-thermal-magnetic-nehb-panelboard-compatible","title":"Square D EHB24015 Bolt-On Molded Case Circuit Breaker – 2 Pole – 15A – Thermal Magnetic – NEHB Panelboard Compatible","description":"\u003cp data-start=\"169\" data-end=\"564\"\u003eThe \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eSquare D\u003c\/span\u003e\u003c\/span\u003e EHB24015 is a molded case circuit breaker designed as a drop-in replacement for legacy commercial and industrial power distribution systems. Manufactured by \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eSchneider Electric\u003c\/span\u003e\u003c\/span\u003e, this 2-pole, 15A breaker provides reliable long-time and instantaneous protection for branch circuits in aging electrical infrastructures.\u003c\/p\u003e\n\u003cp data-start=\"566\" data-end=\"892\"\u003eBuilt specifically for installation in Square D NEHB panelboards, the EHB24015 allows facilities to maintain existing enclosures without requiring a full upgrade to newer NF panelboard systems. It delivers dependable thermal-magnetic protection while supporting continued operation of legacy electrical distribution equipment.\u003c\/p\u003e\n\u003cp data-start=\"894\" data-end=\"1201\"\u003eWith a 14kA interrupting rating at 480Y\/277VAC and 65kA at 120\/240VAC, this breaker is engineered to ensure safe fault interruption in both modern and legacy systems. A Visi-Trip indicator provides quick visual confirmation of a tripped condition, improving maintenance response time and system reliability.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1yl5694\" data-start=\"1203\" data-end=\"1221\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-start=\"1223\" data-end=\"1759\"\u003e\n\u003cli data-section-id=\"lbkw4z\" data-start=\"1223\" data-end=\"1271\"\u003eBrand: \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eSquare D\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1puzkdb\" data-start=\"1272\" data-end=\"1327\"\u003eManufacturer: \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eSchneider Electric\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1apnva4\" data-start=\"1328\" data-end=\"1353\"\u003ePart Number: EHB24015\u003c\/li\u003e\n\u003cli data-section-id=\"ujh38a\" data-start=\"1354\" data-end=\"1376\"\u003eSeries: EHB Series\u003c\/li\u003e\n\u003cli data-section-id=\"19em5gp\" data-start=\"1377\" data-end=\"1414\"\u003eType: Molded Case Circuit Breaker\u003c\/li\u003e\n\u003cli data-section-id=\"utf2jl\" data-start=\"1415\" data-end=\"1440\"\u003eConfiguration: 2 Pole\u003c\/li\u003e\n\u003cli data-section-id=\"vdhrok\" data-start=\"1441\" data-end=\"1459\"\u003ePhase: 1 Phase\u003c\/li\u003e\n\u003cli data-section-id=\"7u5c7y\" data-start=\"1460\" data-end=\"1483\"\u003eCurrent Rating: 15A\u003c\/li\u003e\n\u003cli data-section-id=\"1aqeb2\" data-start=\"1484\" data-end=\"1527\"\u003eVoltage Rating: 480Y\/277VAC, 120\/240VAC\u003c\/li\u003e\n\u003cli data-section-id=\"sybr12\" data-start=\"1528\" data-end=\"1555\"\u003eMounting Style: Bolt-On\u003c\/li\u003e\n\u003cli data-section-id=\"82sw01\" data-start=\"1556\" data-end=\"1589\"\u003eConnection Type: Lug Terminal\u003c\/li\u003e\n\u003cli data-section-id=\"1vwficb\" data-start=\"1590\" data-end=\"1627\"\u003eProtection Type: Thermal Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"1i6wvgf\" data-start=\"1628\" data-end=\"1679\"\u003eTrip Function: LI – Long-Time and Instantaneous\u003c\/li\u003e\n\u003cli data-section-id=\"rn4aoz\" data-start=\"1680\" data-end=\"1709\"\u003eTrip Adjustability: Fixed\u003c\/li\u003e\n\u003cli data-section-id=\"1ck78em\" data-start=\"1710\" data-end=\"1759\"\u003eApplication: NEHB Panelboard \/ Legacy Systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1oyz3ud\" data-start=\"1761\" data-end=\"1785\"\u003eInterrupting Ratings\u003c\/h3\u003e\n\u003cul data-start=\"1787\" data-end=\"1831\"\u003e\n\u003cli data-section-id=\"1b71zsc\" data-start=\"1787\" data-end=\"1809\"\u003e14kA @ 480Y\/277VAC\u003c\/li\u003e\n\u003cli data-section-id=\"14tw7i0\" data-start=\"1810\" data-end=\"1831\"\u003e65kA @ 120\/240VAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1j9na6a\" data-start=\"1833\" data-end=\"1869\"\u003eElectrical \u0026amp; Mechanical Features\u003c\/h3\u003e\n\u003cul data-start=\"1871\" data-end=\"2364\"\u003e\n\u003cli data-section-id=\"1kk480h\" data-start=\"1871\" data-end=\"1924\"\u003eDesigned for legacy NEHB panelboard compatibility\u003c\/li\u003e\n\u003cli data-section-id=\"sppuhf\" data-start=\"1925\" data-end=\"1977\"\u003eDrop-in replacement for older commercial systems\u003c\/li\u003e\n\u003cli data-section-id=\"1o2dnzi\" data-start=\"1978\" data-end=\"2029\"\u003eBolt-on mounting system for secure installation\u003c\/li\u003e\n\u003cli data-section-id=\"1iy4p7f\" data-start=\"2030\" data-end=\"2088\"\u003eThermal-magnetic overload and short-circuit protection\u003c\/li\u003e\n\u003cli data-section-id=\"x5m75h\" data-start=\"2089\" data-end=\"2143\"\u003eFixed LI trip performance for consistent operation\u003c\/li\u003e\n\u003cli data-section-id=\"1kyhqrr\" data-start=\"2144\" data-end=\"2180\"\u003eVisi-Trip visual fault indicator\u003c\/li\u003e\n\u003cli data-section-id=\"1r4745\" data-start=\"2181\" data-end=\"2245\"\u003eSuitable for maintaining aging industrial electrical systems\u003c\/li\u003e\n\u003cli data-section-id=\"1n9xx4e\" data-start=\"2246\" data-end=\"2314\"\u003eSupports continued operation without full panelboard replacement\u003c\/li\u003e\n\u003cli data-section-id=\"pn46iq\" data-start=\"2315\" data-end=\"2364\"\u003eHACR rated construction for HVAC applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"luma9c\" data-start=\"2366\" data-end=\"2380\"\u003eWire Range\u003c\/h3\u003e\n\u003cul data-start=\"2382\" data-end=\"2484\"\u003e\n\u003cli data-section-id=\"5slx2p\" data-start=\"2382\" data-end=\"2402\"\u003eCopper: AWG 14–8\u003c\/li\u003e\n\u003cli data-section-id=\"1xyhwbq\" data-start=\"2403\" data-end=\"2425\"\u003eAluminum: AWG 12–8\u003c\/li\u003e\n\u003cli data-section-id=\"mznkvs\" data-start=\"2426\" data-end=\"2454\"\u003eMaximum wire size: 8 AWG\u003c\/li\u003e\n\u003cli data-section-id=\"hphby3\" data-start=\"2455\" data-end=\"2484\"\u003eMinimum wire size: AWG 14\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"nrk6gw\" data-start=\"2486\" data-end=\"2501\"\u003eAccessories\u003c\/h3\u003e\n\u003cul data-start=\"2503\" data-end=\"2666\"\u003e\n\u003cli data-section-id=\"jojkiv\" data-start=\"2503\" data-end=\"2524\"\u003eShunt trip option\u003c\/li\u003e\n\u003cli data-section-id=\"qfjc38\" data-start=\"2525\" data-end=\"2552\"\u003eAuxiliary switch option\u003c\/li\u003e\n\u003cli data-section-id=\"ygv3rh\" data-start=\"2553\" data-end=\"2576\"\u003eAlarm switch option\u003c\/li\u003e\n\u003cli data-section-id=\"1prr8i7\" data-start=\"2577\" data-end=\"2608\"\u003eUndervoltage release option\u003c\/li\u003e\n\u003cli data-section-id=\"2pnpkb\" data-start=\"2609\" data-end=\"2638\"\u003ePadlock attachment option\u003c\/li\u003e\n\u003cli data-section-id=\"1q3jmzr\" data-start=\"2639\" data-end=\"2666\"\u003eLoad side lugs included\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"131luvw\" data-start=\"2668\" data-end=\"2693\"\u003eStandards \u0026amp; Approvals\u003c\/h3\u003e\n\u003cul data-start=\"2695\" data-end=\"2926\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\n\u003cli data-section-id=\"fjdscg\" data-start=\"2695\" data-end=\"2712\"\u003eUL 489 Listed\u003c\/li\u003e\n\u003cli data-section-id=\"1kuinwb\" data-start=\"2713\" data-end=\"2732\"\u003eCSA C22.2 No. 5\u003c\/li\u003e\n\u003cli data-section-id=\"3h4a0l\" data-start=\"2733\" data-end=\"2749\"\u003eCSA Approved\u003c\/li\u003e\n\u003cli data-section-id=\"10qajj1\" data-start=\"2750\" data-end=\"2765\"\u003eUL Approved\u003c\/li\u003e\n\u003cli data-section-id=\"mq9pch\" data-start=\"2766\" data-end=\"2780\"\u003eHACR Rated\u003c\/li\u003e\n\u003cli data-section-id=\"1fan452\" data-start=\"2781\" data-end=\"2880\"\u003eAuthentic \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eSquare D\u003c\/span\u003e\u003c\/span\u003e \/ \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eSchneider Electric\u003c\/span\u003e\u003c\/span\u003e product\u003c\/li\u003e\n\u003cli data-section-id=\"pk3dpl\" data-start=\"2881\" data-end=\"2926\" data-is-last-node=\"\"\u003eDesigned for NEHB legacy panelboard systems\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Square D","offers":[{"title":"NEW","offer_id":48529687576825,"sku":"EHB24015","price":125.43,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/ehb24015_1_1024x_f03029c7-e64d-4167-b1af-a2a28f88862b.webp?v=1781466277","url":"https:\/\/mycircuitbreakers.com\/products\/square-d-ehb24015-bolt-on-molded-case-circuit-breaker-2-pole-15a-thermal-magnetic-nehb-panelboard-compatible","provider":"My Circuit Breakers","version":"1.0","type":"link"}