{"product_id":"square-d-h363rb-heavy-duty-safety-switch-100a-3-pole-600vac-dc-fusible-disconnect-nema-3r-outdoor-enclosure","title":"Square D H363RB Heavy Duty Safety Switch – 100A – 3 Pole – 600VAC\/DC – Fusible Disconnect – NEMA 3R Outdoor Enclosure","description":"\u003cp data-start=\"144\" data-end=\"550\"\u003eThe Square D H363RB Heavy Duty Safety Switch from Schneider Electric's F Series is a rugged, high-performance fusible disconnect switch engineered for demanding commercial, industrial, and utility applications. Designed to provide a reliable means of power isolation and equipment protection, this 3-pole safety switch features a 100A current rating and supports systems up to 600VAC\/DC.\u003c\/p\u003e\n\u003cp data-start=\"552\" data-end=\"949\"\u003eBuilt for durability in harsh environments, the H363RB incorporates a quick-make, quick-break operating mechanism that delivers dependable switching performance and enhanced operator safety. The switch also features a dual cover interlock that helps prevent accidental access to live components while the switch is energized, along with a color-coded handle that clearly indicates switch position.\u003c\/p\u003e\n\u003cp data-start=\"951\" data-end=\"1330\"\u003eThe NEMA 3R galvannealed steel enclosure provides protection against rain, sleet, and outdoor environmental conditions, making it suitable for both indoor and outdoor installations. Designed to accept H, J, K, L, and R class fuses, the switch offers flexible overcurrent protection options and a short-circuit current rating up to 200kA when used with the appropriate fuse class.\u003c\/p\u003e\n\u003cp data-start=\"1332\" data-end=\"1566\"\u003eEngineered to exceed NEMA KS-1 and UL 98 mechanical endurance requirements, the H363RB delivers long service life and dependable performance in motor control, power distribution, service entrance, and equipment isolation applications.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1yl5694\" data-start=\"1573\" data-end=\"1591\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-start=\"1593\" data-end=\"2121\"\u003e\n\u003cli data-section-id=\"yuqlrx\" data-start=\"1593\" data-end=\"1638\"\u003e\n\u003cstrong data-start=\"1595\" data-end=\"1605\"\u003eBrand:\u003c\/strong\u003e Square D by Schneider Electric\u003c\/li\u003e\n\u003cli data-section-id=\"dn3u0f\" data-start=\"1639\" data-end=\"1679\"\u003e\n\u003cstrong data-start=\"1641\" data-end=\"1658\"\u003eManufacturer:\u003c\/strong\u003e Schneider Electric\u003c\/li\u003e\n\u003cli data-section-id=\"1q1y8w8\" data-start=\"1680\" data-end=\"1707\"\u003e\n\u003cstrong data-start=\"1682\" data-end=\"1698\"\u003ePart Number:\u003c\/strong\u003e H363RB\u003c\/li\u003e\n\u003cli data-section-id=\"1affqz6\" data-start=\"1708\" data-end=\"1740\"\u003e\n\u003cstrong data-start=\"1710\" data-end=\"1729\"\u003eProduct Family:\u003c\/strong\u003e F Series\u003c\/li\u003e\n\u003cli data-section-id=\"e6v92b\" data-start=\"1741\" data-end=\"1786\"\u003e\n\u003cstrong data-start=\"1743\" data-end=\"1759\"\u003eDevice Type:\u003c\/strong\u003e Heavy Duty Safety Switch\u003c\/li\u003e\n\u003cli data-section-id=\"91j5sq\" data-start=\"1787\" data-end=\"1826\"\u003e\n\u003cstrong data-start=\"1789\" data-end=\"1805\"\u003eSwitch Type:\u003c\/strong\u003e Fusible Disconnect\u003c\/li\u003e\n\u003cli data-section-id=\"spvjtc\" data-start=\"1827\" data-end=\"1859\"\u003e\n\u003cstrong data-start=\"1829\" data-end=\"1844\"\u003eThrow Type:\u003c\/strong\u003e Single Throw\u003c\/li\u003e\n\u003cli data-section-id=\"4h7p0y\" data-start=\"1860\" data-end=\"1881\"\u003e\n\u003cstrong data-start=\"1862\" data-end=\"1872\"\u003ePoles:\u003c\/strong\u003e 3 Pole\u003c\/li\u003e\n\u003cli data-section-id=\"7rlmjw\" data-start=\"1882\" data-end=\"1910\"\u003e\n\u003cstrong data-start=\"1884\" data-end=\"1903\"\u003eCurrent Rating:\u003c\/strong\u003e 100A\u003c\/li\u003e\n\u003cli data-section-id=\"y2658d\" data-start=\"1911\" data-end=\"1944\"\u003e\n\u003cstrong data-start=\"1913\" data-end=\"1932\"\u003eVoltage Rating:\u003c\/strong\u003e 600VAC\/DC\u003c\/li\u003e\n\u003cli data-section-id=\"2m1oe9\" data-start=\"1945\" data-end=\"1967\"\u003e\n\u003cstrong data-start=\"1947\" data-end=\"1957\"\u003ePhase:\u003c\/strong\u003e 3 Phase\u003c\/li\u003e\n\u003cli data-section-id=\"1b8eyb\" data-start=\"1968\" data-end=\"2005\"\u003e\n\u003cstrong data-start=\"1970\" data-end=\"1982\"\u003eNeutral:\u003c\/strong\u003e No Neutral Installed\u003c\/li\u003e\n\u003cli data-section-id=\"w52win\" data-start=\"2006\" data-end=\"2042\"\u003e\n\u003cstrong data-start=\"2008\" data-end=\"2026\"\u003eMounting Type:\u003c\/strong\u003e Surface Mount\u003c\/li\u003e\n\u003cli data-section-id=\"4vzy1l\" data-start=\"2043\" data-end=\"2087\"\u003e\n\u003cstrong data-start=\"2045\" data-end=\"2071\"\u003eFuse Classes Accepted:\u003c\/strong\u003e H, J, K, L, R\u003c\/li\u003e\n\u003cli data-section-id=\"1ib4knd\" data-start=\"2088\" data-end=\"2121\"\u003e\n\u003cstrong data-start=\"2090\" data-end=\"2111\"\u003eEnclosure Rating:\u003c\/strong\u003e NEMA 3R\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1g5d8j4\" data-start=\"2128\" data-end=\"2154\"\u003eElectrical Performance\u003c\/h3\u003e\n\u003cul data-start=\"2156\" data-end=\"2436\"\u003e\n\u003cli data-section-id=\"1fnp7jh\" data-start=\"2156\" data-end=\"2183\"\u003e\n\u003cstrong data-start=\"2158\" data-end=\"2176\"\u003eRated Current:\u003c\/strong\u003e 100A\u003c\/li\u003e\n\u003cli data-section-id=\"9u5flo\" data-start=\"2184\" data-end=\"2216\"\u003e\n\u003cstrong data-start=\"2186\" data-end=\"2204\"\u003eRated Voltage:\u003c\/strong\u003e 600VAC\/DC\u003c\/li\u003e\n\u003cli data-section-id=\"1g5vr6b\" data-start=\"2217\" data-end=\"2297\"\u003e\n\u003cstrong data-start=\"2219\" data-end=\"2259\"\u003eShort-Circuit Current Rating (SCCR):\u003c\/strong\u003e 10kA–200kA (depending on fuse type)\u003c\/li\u003e\n\u003cli data-section-id=\"rw7t46\" data-start=\"2298\" data-end=\"2330\"\u003e\n\u003cstrong data-start=\"2300\" data-end=\"2315\"\u003eAIC Rating:\u003c\/strong\u003e 200kA @ 600V\u003c\/li\u003e\n\u003cli data-section-id=\"1rjlpro\" data-start=\"2331\" data-end=\"2378\"\u003e\n\u003cstrong data-start=\"2333\" data-end=\"2372\"\u003eQuick-Make \/ Quick-Break Mechanism:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli data-section-id=\"gjoeg3\" data-start=\"2379\" data-end=\"2436\"\u003e\n\u003cstrong data-start=\"2381\" data-end=\"2430\"\u003eSuitable for Service Disconnect Applications:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1qpthm9\" data-start=\"2443\" data-end=\"2481\"\u003eMechanical \u0026amp; Construction Features\u003c\/h3\u003e\n\u003cul data-start=\"2483\" data-end=\"2867\"\u003e\n\u003cli data-section-id=\"75klcq\" data-start=\"2483\" data-end=\"2519\"\u003eHeavy-duty F Series construction\u003c\/li\u003e\n\u003cli data-section-id=\"g4eq7z\" data-start=\"2520\" data-end=\"2564\"\u003eDual cover interlock for enhanced safety\u003c\/li\u003e\n\u003cli data-section-id=\"c0qwiu\" data-start=\"2565\" data-end=\"2597\"\u003eColor-coded operating handle\u003c\/li\u003e\n\u003cli data-section-id=\"5piolc\" data-start=\"2598\" data-end=\"2634\"\u003eSingle-throw switching mechanism\u003c\/li\u003e\n\u003cli data-section-id=\"4xo0ct\" data-start=\"2635\" data-end=\"2667\"\u003eGalvannealed steel enclosure\u003c\/li\u003e\n\u003cli data-section-id=\"1fvezpi\" data-start=\"2668\" data-end=\"2714\"\u003eOutdoor and indoor installation capability\u003c\/li\u003e\n\u003cli data-section-id=\"1gmocdq\" data-start=\"2715\" data-end=\"2741\"\u003eSurface-mounted design\u003c\/li\u003e\n\u003cli data-section-id=\"b4gth8\" data-start=\"2742\" data-end=\"2796\"\u003eExceeds NEMA KS-1 and UL 98 endurance requirements\u003c\/li\u003e\n\u003cli data-section-id=\"1c43tq8\" data-start=\"2797\" data-end=\"2867\"\u003eLong mechanical service life for demanding industrial applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"tsjdab\" data-start=\"2874\" data-end=\"2897\"\u003eDimensions \u0026amp; Weight\u003c\/h3\u003e\n\u003cul data-start=\"2899\" data-end=\"2981\"\u003e\n\u003cli data-section-id=\"23adg3\" data-start=\"2899\" data-end=\"2955\"\u003e\n\u003cstrong data-start=\"2901\" data-end=\"2928\"\u003eDimensions (H × W × D):\u003c\/strong\u003e 6.38 × 10.25 × 21.25 in.\u003c\/li\u003e\n\u003cli data-section-id=\"o80ypx\" data-start=\"2956\" data-end=\"2981\"\u003e\n\u003cstrong data-start=\"2958\" data-end=\"2969\"\u003eWeight:\u003c\/strong\u003e 19.84 lbs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"wggvqn\" data-start=\"2988\" data-end=\"3004\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"3006\" data-end=\"3286\"\u003e\n\u003cli data-section-id=\"n7lx3w\" data-start=\"3006\" data-end=\"3047\"\u003eIndustrial power distribution systems\u003c\/li\u003e\n\u003cli data-section-id=\"1tlhpfw\" data-start=\"3048\" data-end=\"3082\"\u003eMotor disconnect and isolation\u003c\/li\u003e\n\u003cli data-section-id=\"1lgi4c8\" data-start=\"3083\" data-end=\"3127\"\u003eService entrance disconnect applications\u003c\/li\u003e\n\u003cli data-section-id=\"6949a2\" data-start=\"3128\" data-end=\"3156\"\u003eHVAC equipment isolation\u003c\/li\u003e\n\u003cli data-section-id=\"1vtmva7\" data-start=\"3157\" data-end=\"3204\"\u003eManufacturing facilities and process plants\u003c\/li\u003e\n\u003cli data-section-id=\"nt99p1\" data-start=\"3205\" data-end=\"3244\"\u003eCommercial electrical installations\u003c\/li\u003e\n\u003cli data-section-id=\"gf2pce\" data-start=\"3245\" data-end=\"3286\"\u003eOutdoor equipment disconnecting means\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"p3m70j\" data-start=\"3293\" data-end=\"3323\"\u003eStandards \u0026amp; Certifications\u003c\/h3\u003e\n\u003cul data-start=\"3325\" data-end=\"3464\"\u003e\n\u003cli data-section-id=\"1w9xzw2\" data-start=\"3325\" data-end=\"3338\"\u003eUL Listed\u003c\/li\u003e\n\u003cli data-section-id=\"1xqik9e\" data-start=\"3339\" data-end=\"3355\"\u003eCSA Approved\u003c\/li\u003e\n\u003cli data-section-id=\"1ch7vw2\" data-start=\"3356\" data-end=\"3383\"\u003eNEMA 3R Rated Enclosure\u003c\/li\u003e\n\u003cli data-section-id=\"7bj9g8\" data-start=\"3384\" data-end=\"3427\"\u003eUL 98 Safety Switch Standard Compliance\u003c\/li\u003e\n\u003cli data-section-id=\"10dwz1q\" data-start=\"3428\" data-end=\"3464\"\u003eNEMA KS-1 Performance Compliance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"rwm0ne\" data-start=\"3471\" data-end=\"3496\"\u003eEnvironmental Ratings\u003c\/h3\u003e\n\u003cul data-start=\"3498\" data-end=\"3719\"\u003e\n\u003cli data-section-id=\"1t6ibv4\" data-start=\"3498\" data-end=\"3537\"\u003eNEMA 3R weather-resistant enclosure\u003c\/li\u003e\n\u003cli data-section-id=\"e63plh\" data-start=\"3538\" data-end=\"3576\"\u003eSuitable for outdoor installations\u003c\/li\u003e\n\u003cli data-section-id=\"1sp3eqn\" data-start=\"3577\" data-end=\"3612\"\u003eRain and sleet resistant design\u003c\/li\u003e\n\u003cli data-section-id=\"1yd3kwe\" data-start=\"3613\" data-end=\"3668\"\u003eCorrosion-resistant galvannealed steel construction\u003c\/li\u003e\n\u003cli data-section-id=\"1e1mwhy\" data-start=\"3669\" data-end=\"3719\"\u003eDesigned for demanding industrial environments\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Square D","offers":[{"title":"NEW","offer_id":48531401801977,"sku":"H363RB","price":1020.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/H363RB-New-1_2ec9f64c-d234-417a-bd25-b6bdf7cf2b7c.webp?v=1781520781","url":"https:\/\/mycircuitbreakers.com\/products\/square-d-h363rb-heavy-duty-safety-switch-100a-3-pole-600vac-dc-fusible-disconnect-nema-3r-outdoor-enclosure","provider":"My Circuit Breakers","version":"1.0","type":"link"}