{"product_id":"square-d-hda260501-powerpact-circuit-breaker-2-pole-50a-600v-thermal-magnetic-i-line-plug-in-18ka-480v","title":"Square D HDA260501 PowerPact Circuit Breaker – 2 Pole – 50A – 600V – Thermal Magnetic – I-Line Plug-In – 18kA @ 480V","description":"\u003cp data-start=\"143\" data-end=\"560\"\u003eThe Square D HDA260501 PowerPact Circuit Breaker is a high-performance molded case circuit breaker designed for dependable protection of electrical distribution systems in commercial and industrial environments. Manufactured by Schneider Electric and part of the PowerPact H-Frame family, this 2-pole breaker provides reliable thermal-magnetic protection against overloads and short-circuit faults.\u003c\/p\u003e\n\u003cp data-start=\"562\" data-end=\"931\"\u003eRated at 50A and 600V AC, the HDA260501 incorporates a non-interchangeable thermal-magnetic trip unit with Long-Time and Instantaneous (LI) protection functions. The thermal element responds to prolonged overload conditions, while the magnetic trip mechanism delivers rapid interruption of high fault currents to help protect conductors, equipment, and connected loads.\u003c\/p\u003e\n\u003cp data-start=\"933\" data-end=\"1291\"\u003eThe breaker features an I-Line style plug-in connection and mounting bracket design for quick installation into compatible Square D I-Line panelboards and switchboards. Configured with an A \u0026amp; B phase connection arrangement, the HDA260501 offers a standard interrupting capacity of 18kA at 480V AC and includes load-side lug terminals for secure field wiring.\u003c\/p\u003e\n\u003cp data-start=\"1293\" data-end=\"1572\"\u003eIts compact H-Frame design, toggle operating handle, and rugged molded case construction make the HDA260501 an excellent solution for branch circuit protection, feeder applications, and industrial power distribution systems requiring reliable and long-lasting circuit protection.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1yl5694\" data-start=\"1579\" data-end=\"1597\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-start=\"1599\" data-end=\"2300\"\u003e\n\u003cli data-section-id=\"yuqlrx\" data-start=\"1599\" data-end=\"1644\"\u003e\n\u003cstrong data-start=\"1601\" data-end=\"1611\"\u003eBrand:\u003c\/strong\u003e Square D by Schneider Electric\u003c\/li\u003e\n\u003cli data-section-id=\"dn3u0f\" data-start=\"1645\" data-end=\"1685\"\u003e\n\u003cstrong data-start=\"1647\" data-end=\"1664\"\u003eManufacturer:\u003c\/strong\u003e Schneider Electric\u003c\/li\u003e\n\u003cli data-section-id=\"i757v\" data-start=\"1686\" data-end=\"1716\"\u003e\n\u003cstrong data-start=\"1688\" data-end=\"1704\"\u003ePart Number:\u003c\/strong\u003e HDA260501\u003c\/li\u003e\n\u003cli data-section-id=\"173mfna\" data-start=\"1717\" data-end=\"1750\"\u003e\n\u003cstrong data-start=\"1719\" data-end=\"1738\"\u003eProduct Family:\u003c\/strong\u003e PowerPact\u003c\/li\u003e\n\u003cli data-section-id=\"18sditb\" data-start=\"1751\" data-end=\"1777\"\u003e\n\u003cstrong data-start=\"1753\" data-end=\"1764\"\u003eSeries:\u003c\/strong\u003e HDA Series\u003c\/li\u003e\n\u003cli data-section-id=\"1wqn2gf\" data-start=\"1778\" data-end=\"1805\"\u003e\n\u003cstrong data-start=\"1780\" data-end=\"1795\"\u003eFrame Type:\u003c\/strong\u003e H-Frame\u003c\/li\u003e\n\u003cli data-section-id=\"146cpau\" data-start=\"1806\" data-end=\"1854\"\u003e\n\u003cstrong data-start=\"1808\" data-end=\"1824\"\u003eDevice Type:\u003c\/strong\u003e Molded Case Circuit Breaker\u003c\/li\u003e\n\u003cli data-section-id=\"3rae9l\" data-start=\"1855\" data-end=\"1886\"\u003e\n\u003cstrong data-start=\"1857\" data-end=\"1877\"\u003eNumber of Poles:\u003c\/strong\u003e 2 Pole\u003c\/li\u003e\n\u003cli data-section-id=\"1waosar\" data-start=\"1887\" data-end=\"1909\"\u003e\n\u003cstrong data-start=\"1889\" data-end=\"1899\"\u003ePhase:\u003c\/strong\u003e 1 Phase\u003c\/li\u003e\n\u003cli data-section-id=\"1m9wgl4\" data-start=\"1910\" data-end=\"1937\"\u003e\n\u003cstrong data-start=\"1912\" data-end=\"1931\"\u003eCurrent Rating:\u003c\/strong\u003e 50A\u003c\/li\u003e\n\u003cli data-section-id=\"1hnihrp\" data-start=\"1938\" data-end=\"1969\"\u003e\n\u003cstrong data-start=\"1940\" data-end=\"1959\"\u003eVoltage Rating:\u003c\/strong\u003e 600V AC\u003c\/li\u003e\n\u003cli data-section-id=\"su17fp\" data-start=\"1970\" data-end=\"2015\"\u003e\n\u003cstrong data-start=\"1972\" data-end=\"1992\"\u003eConnection Type:\u003c\/strong\u003e I-Line Style Plug-In\u003c\/li\u003e\n\u003cli data-section-id=\"obgi8u\" data-start=\"2016\" data-end=\"2053\"\u003e\n\u003cstrong data-start=\"2018\" data-end=\"2036\"\u003eMounting Mode:\u003c\/strong\u003e I-Line Bracket\u003c\/li\u003e\n\u003cli data-section-id=\"12rvexo\" data-start=\"2054\" data-end=\"2095\"\u003e\n\u003cstrong data-start=\"2056\" data-end=\"2076\"\u003eProtection Type:\u003c\/strong\u003e Thermal Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"x2h85\" data-start=\"2096\" data-end=\"2142\"\u003e\n\u003cstrong data-start=\"2098\" data-end=\"2123\"\u003eTrip Unit Technology:\u003c\/strong\u003e Thermal-Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"r8shq1\" data-start=\"2143\" data-end=\"2199\"\u003e\n\u003cstrong data-start=\"2145\" data-end=\"2164\"\u003eTrip Functions:\u003c\/strong\u003e LI (Long-Time and Instantaneous)\u003c\/li\u003e\n\u003cli data-section-id=\"3tu44f\" data-start=\"2200\" data-end=\"2228\"\u003e\n\u003cstrong data-start=\"2202\" data-end=\"2219\"\u003eControl Type:\u003c\/strong\u003e Toggle\u003c\/li\u003e\n\u003cli data-section-id=\"1m5b7hs\" data-start=\"2229\" data-end=\"2262\"\u003e\n\u003cstrong data-start=\"2231\" data-end=\"2258\"\u003eBreaking Capacity Code:\u003c\/strong\u003e D\u003c\/li\u003e\n\u003cli data-section-id=\"1yaswht\" data-start=\"2263\" data-end=\"2300\"\u003e\n\u003cstrong data-start=\"2265\" data-end=\"2286\"\u003ePhase Connection:\u003c\/strong\u003e A \u0026amp; B Phase\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1g5d8j4\" data-start=\"2307\" data-end=\"2333\"\u003eElectrical Performance\u003c\/h3\u003e\n\u003cul data-start=\"2335\" data-end=\"2712\"\u003e\n\u003cli data-section-id=\"7y0w9l\" data-start=\"2335\" data-end=\"2361\"\u003e\n\u003cstrong data-start=\"2337\" data-end=\"2355\"\u003eRated Current:\u003c\/strong\u003e 50A\u003c\/li\u003e\n\u003cli data-section-id=\"1v8p00q\" data-start=\"2362\" data-end=\"2394\"\u003e\n\u003cstrong data-start=\"2364\" data-end=\"2384\"\u003eMaximum Voltage:\u003c\/strong\u003e 600V AC\u003c\/li\u003e\n\u003cli data-section-id=\"1rzypbe\" data-start=\"2395\" data-end=\"2440\"\u003e\n\u003cstrong data-start=\"2397\" data-end=\"2423\"\u003eInterrupting Capacity:\u003c\/strong\u003e 18kA @ 480V AC\u003c\/li\u003e\n\u003cli data-section-id=\"1oi0xwc\" data-start=\"2441\" data-end=\"2479\"\u003e\n\u003cstrong data-start=\"2443\" data-end=\"2473\"\u003eContinuous Current Rating:\u003c\/strong\u003e 80%\u003c\/li\u003e\n\u003cli data-section-id=\"uype7z\" data-start=\"2480\" data-end=\"2515\"\u003e\n\u003cstrong data-start=\"2482\" data-end=\"2508\"\u003eMagnetic Hold Current:\u003c\/strong\u003e 400A\u003c\/li\u003e\n\u003cli data-section-id=\"do9l41\" data-start=\"2516\" data-end=\"2554\"\u003e\n\u003cstrong data-start=\"2518\" data-end=\"2532\"\u003eTrip Unit:\u003c\/strong\u003e Non-Interchangeable\u003c\/li\u003e\n\u003cli data-section-id=\"1h1tonz\" data-start=\"2555\" data-end=\"2606\"\u003e\n\u003cstrong data-start=\"2557\" data-end=\"2581\"\u003eOverload Protection:\u003c\/strong\u003e Long-Time Thermal Trip\u003c\/li\u003e\n\u003cli data-section-id=\"xtoiys\" data-start=\"2607\" data-end=\"2668\"\u003e\n\u003cstrong data-start=\"2609\" data-end=\"2638\"\u003eShort-Circuit Protection:\u003c\/strong\u003e Instantaneous Magnetic Trip\u003c\/li\u003e\n\u003cli data-section-id=\"ggdhat\" data-start=\"2669\" data-end=\"2712\"\u003e\n\u003cstrong data-start=\"2671\" data-end=\"2706\"\u003eStandard Interrupting Capacity:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1qpthm9\" data-start=\"2719\" data-end=\"2757\"\u003eMechanical \u0026amp; Construction Features\u003c\/h3\u003e\n\u003cul data-start=\"2759\" data-end=\"3134\"\u003e\n\u003cli data-section-id=\"u0gwk2\" data-start=\"2759\" data-end=\"2795\"\u003eH-Frame molded case construction\u003c\/li\u003e\n\u003cli data-section-id=\"tjapfe\" data-start=\"2796\" data-end=\"2825\"\u003eCompact industrial design\u003c\/li\u003e\n\u003cli data-section-id=\"1alw3pq\" data-start=\"2826\" data-end=\"2860\"\u003eI-Line plug-in mounting system\u003c\/li\u003e\n\u003cli data-section-id=\"1nus1yd\" data-start=\"2861\" data-end=\"2888\"\u003eToggle handle operation\u003c\/li\u003e\n\u003cli data-section-id=\"1tf21cz\" data-start=\"2889\" data-end=\"2939\"\u003eNon-interchangeable thermal-magnetic trip unit\u003c\/li\u003e\n\u003cli data-section-id=\"10c3wyx\" data-start=\"2940\" data-end=\"2973\"\u003eRugged molded insulating case\u003c\/li\u003e\n\u003cli data-section-id=\"phaweh\" data-start=\"2974\" data-end=\"3010\"\u003eLoad-side lug terminals included\u003c\/li\u003e\n\u003cli data-section-id=\"qylurg\" data-start=\"3011\" data-end=\"3085\"\u003eDesigned for commercial and industrial power distribution applications\u003c\/li\u003e\n\u003cli data-section-id=\"wg6se6\" data-start=\"3086\" data-end=\"3134\"\u003eLong service life and dependable performance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"cn8pd9\" data-start=\"3141\" data-end=\"3167\"\u003eElectrical Connections\u003c\/h3\u003e\n\u003cul data-start=\"3169\" data-end=\"3345\"\u003e\n\u003cli data-section-id=\"ketr92\" data-start=\"3169\" data-end=\"3211\"\u003e\n\u003cstrong data-start=\"3171\" data-end=\"3191\"\u003eLine Connection:\u003c\/strong\u003e I-Line Connection\u003c\/li\u003e\n\u003cli data-section-id=\"1w10knf\" data-start=\"3212\" data-end=\"3250\"\u003e\n\u003cstrong data-start=\"3214\" data-end=\"3234\"\u003eLoad Connection:\u003c\/strong\u003e Lug Terminals\u003c\/li\u003e\n\u003cli data-section-id=\"1kdq9vt\" data-start=\"3251\" data-end=\"3302\"\u003e\n\u003cstrong data-start=\"3253\" data-end=\"3281\"\u003eConductor Compatibility:\u003c\/strong\u003e Copper or Aluminum\u003c\/li\u003e\n\u003cli data-section-id=\"1gm3hyr\" data-start=\"3303\" data-end=\"3345\"\u003e\n\u003cstrong data-start=\"3305\" data-end=\"3325\"\u003eWire Size Range:\u003c\/strong\u003e AWG 14 to AWG 3\/0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"tsjdab\" data-start=\"3352\" data-end=\"3375\"\u003eDimensions \u0026amp; Weight\u003c\/h3\u003e\n\u003cul data-start=\"3377\" data-end=\"3455\"\u003e\n\u003cli data-section-id=\"1wbclh5\" data-start=\"3377\" data-end=\"3430\"\u003e\n\u003cstrong data-start=\"3379\" data-end=\"3406\"\u003eDimensions (H × W × D):\u003c\/strong\u003e 9.73\" × 2.94\" × 4.80\"\u003c\/li\u003e\n\u003cli data-section-id=\"uwebh1\" data-start=\"3431\" data-end=\"3455\"\u003e\n\u003cstrong data-start=\"3433\" data-end=\"3444\"\u003eWeight:\u003c\/strong\u003e 1.36 lbs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"wggvqn\" data-start=\"3462\" data-end=\"3478\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"3480\" data-end=\"3817\"\u003e\n\u003cli data-section-id=\"1b02wdy\" data-start=\"3480\" data-end=\"3526\"\u003eCommercial electrical distribution systems\u003c\/li\u003e\n\u003cli data-section-id=\"1kbdpgg\" data-start=\"3527\" data-end=\"3570\"\u003eIndustrial power distribution equipment\u003c\/li\u003e\n\u003cli data-section-id=\"1w0n024\" data-start=\"3571\" data-end=\"3600\"\u003eBranch circuit protection\u003c\/li\u003e\n\u003cli data-section-id=\"ur0r8t\" data-start=\"3601\" data-end=\"3630\"\u003eFeeder circuit protection\u003c\/li\u003e\n\u003cli data-section-id=\"c1588\" data-start=\"3631\" data-end=\"3662\"\u003eSquare D I-Line panelboards\u003c\/li\u003e\n\u003cli data-section-id=\"932g64\" data-start=\"3663\" data-end=\"3695\"\u003eSquare D I-Line switchboards\u003c\/li\u003e\n\u003cli data-section-id=\"ht42qz\" data-start=\"3696\" data-end=\"3724\"\u003eManufacturing facilities\u003c\/li\u003e\n\u003cli data-section-id=\"1uph824\" data-start=\"3725\" data-end=\"3761\"\u003eControl panels and OEM equipment\u003c\/li\u003e\n\u003cli data-section-id=\"1i9jj6s\" data-start=\"3762\" data-end=\"3817\"\u003eElectrical infrastructure upgrades and replacements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"p3m70j\" data-start=\"3824\" data-end=\"3854\"\u003eStandards \u0026amp; Certifications\u003c\/h3\u003e\n\u003cul data-start=\"3856\" data-end=\"4033\"\u003e\n\u003cli data-section-id=\"1w9xzw2\" data-start=\"3856\" data-end=\"3869\"\u003eUL Listed\u003c\/li\u003e\n\u003cli data-section-id=\"1xqik9e\" data-start=\"3870\" data-end=\"3886\"\u003eCSA Approved\u003c\/li\u003e\n\u003cli data-section-id=\"1bcqbuy\" data-start=\"3887\" data-end=\"3965\"\u003eManufactured to applicable PowerPact molded case circuit breaker standards\u003c\/li\u003e\n\u003cli data-section-id=\"1y61nyr\" data-start=\"3966\" data-end=\"4033\"\u003eSuitable for commercial and industrial electrical installations\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Square D","offers":[{"title":"NEW","offer_id":48533275541753,"sku":"HDA260501","price":727.65,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/HDA260252-new-1_f2d8069d-ee63-4979-b5c9-d56b7cec29cc.jpg?v=1781596179","url":"https:\/\/mycircuitbreakers.com\/products\/square-d-hda260501-powerpact-circuit-breaker-2-pole-50a-600v-thermal-magnetic-i-line-plug-in-18ka-480v","provider":"My Circuit Breakers","version":"1.0","type":"link"}