{"product_id":"square-d-hda260604-powerpact-circuit-breaker-2-pole-60a-600v-thermal-magnetic-i-line-plug-in-18ka-480v","title":"Square D HDA260604 PowerPact Circuit Breaker – 2 Pole – 60A – 600V – Thermal Magnetic – I-Line Plug-In – 18kA @ 480V","description":"\u003cp data-start=\"143\" data-end=\"605\"\u003eThe Square D HDA260604 PowerPact Circuit Breaker is a molded case circuit breaker designed for dependable overload and short-circuit protection in commercial and industrial electrical distribution systems. Manufactured by Schneider Electric under the PowerPact H-Frame series, this 2-pole breaker combines thermal-magnetic trip protection with a convenient I-Line plug-in mounting system for fast installation in compatible Square D equipment.\u003c\/p\u003e\n\u003cp data-start=\"607\" data-end=\"979\"\u003eRated at 60A and 600V AC, the HDA260604 features a non-interchangeable thermal-magnetic trip unit with Long-Time and Instantaneous (LI) protection functions. The thermal element provides protection against sustained overload conditions, while the instantaneous magnetic element responds quickly to short-circuit faults, helping protect downstream equipment and conductors.\u003c\/p\u003e\n\u003cp data-start=\"981\" data-end=\"1246\"\u003eThis model is designed with a B \u0026amp; C phase connection arrangement and is intended for use in Square D I-Line panelboards and switchboards. The I-Line plug-in design ensures secure electrical connection and efficient installation or replacement in field applications.\u003c\/p\u003e\n\u003cp data-start=\"1248\" data-end=\"1467\"\u003eWith a standard interrupting capacity of 18kA at 480V AC and reverse-feed capability, the HDA260604 is suitable for a wide range of branch circuit and feeder protection applications in modern power distribution systems.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1yl5694\" data-start=\"1474\" data-end=\"1492\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-start=\"1494\" data-end=\"2195\"\u003e\n\u003cli data-section-id=\"yuqlrx\" data-start=\"1494\" data-end=\"1539\"\u003e\n\u003cstrong data-start=\"1496\" data-end=\"1506\"\u003eBrand:\u003c\/strong\u003e Square D by Schneider Electric\u003c\/li\u003e\n\u003cli data-section-id=\"dn3u0f\" data-start=\"1540\" data-end=\"1580\"\u003e\n\u003cstrong data-start=\"1542\" data-end=\"1559\"\u003eManufacturer:\u003c\/strong\u003e Schneider Electric\u003c\/li\u003e\n\u003cli data-section-id=\"iv3cd\" data-start=\"1581\" data-end=\"1611\"\u003e\n\u003cstrong data-start=\"1583\" data-end=\"1599\"\u003ePart Number:\u003c\/strong\u003e HDA260604\u003c\/li\u003e\n\u003cli data-section-id=\"173mfna\" data-start=\"1612\" data-end=\"1645\"\u003e\n\u003cstrong data-start=\"1614\" data-end=\"1633\"\u003eProduct Family:\u003c\/strong\u003e PowerPact\u003c\/li\u003e\n\u003cli data-section-id=\"18sditb\" data-start=\"1646\" data-end=\"1672\"\u003e\n\u003cstrong data-start=\"1648\" data-end=\"1659\"\u003eSeries:\u003c\/strong\u003e HDA Series\u003c\/li\u003e\n\u003cli data-section-id=\"1wqn2gf\" data-start=\"1673\" data-end=\"1700\"\u003e\n\u003cstrong data-start=\"1675\" data-end=\"1690\"\u003eFrame Type:\u003c\/strong\u003e H-Frame\u003c\/li\u003e\n\u003cli data-section-id=\"146cpau\" data-start=\"1701\" data-end=\"1749\"\u003e\n\u003cstrong data-start=\"1703\" data-end=\"1719\"\u003eDevice Type:\u003c\/strong\u003e Molded Case Circuit Breaker\u003c\/li\u003e\n\u003cli data-section-id=\"3rae9l\" data-start=\"1750\" data-end=\"1781\"\u003e\n\u003cstrong data-start=\"1752\" data-end=\"1772\"\u003eNumber of Poles:\u003c\/strong\u003e 2 Pole\u003c\/li\u003e\n\u003cli data-section-id=\"1waosar\" data-start=\"1782\" data-end=\"1804\"\u003e\n\u003cstrong data-start=\"1784\" data-end=\"1794\"\u003ePhase:\u003c\/strong\u003e 1 Phase\u003c\/li\u003e\n\u003cli data-section-id=\"1mbz9mj\" data-start=\"1805\" data-end=\"1832\"\u003e\n\u003cstrong data-start=\"1807\" data-end=\"1826\"\u003eCurrent Rating:\u003c\/strong\u003e 60A\u003c\/li\u003e\n\u003cli data-section-id=\"1hnihrp\" data-start=\"1833\" data-end=\"1864\"\u003e\n\u003cstrong data-start=\"1835\" data-end=\"1854\"\u003eVoltage Rating:\u003c\/strong\u003e 600V AC\u003c\/li\u003e\n\u003cli data-section-id=\"su17fp\" data-start=\"1865\" data-end=\"1910\"\u003e\n\u003cstrong data-start=\"1867\" data-end=\"1887\"\u003eConnection Type:\u003c\/strong\u003e I-Line Style Plug-In\u003c\/li\u003e\n\u003cli data-section-id=\"obgi8u\" data-start=\"1911\" data-end=\"1948\"\u003e\n\u003cstrong data-start=\"1913\" data-end=\"1931\"\u003eMounting Mode:\u003c\/strong\u003e I-Line Bracket\u003c\/li\u003e\n\u003cli data-section-id=\"12rvexo\" data-start=\"1949\" data-end=\"1990\"\u003e\n\u003cstrong data-start=\"1951\" data-end=\"1971\"\u003eProtection Type:\u003c\/strong\u003e Thermal Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"x2h85\" data-start=\"1991\" data-end=\"2037\"\u003e\n\u003cstrong data-start=\"1993\" data-end=\"2018\"\u003eTrip Unit Technology:\u003c\/strong\u003e Thermal-Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"r8shq1\" data-start=\"2038\" data-end=\"2094\"\u003e\n\u003cstrong data-start=\"2040\" data-end=\"2059\"\u003eTrip Functions:\u003c\/strong\u003e LI (Long-Time and Instantaneous)\u003c\/li\u003e\n\u003cli data-section-id=\"3tu44f\" data-start=\"2095\" data-end=\"2123\"\u003e\n\u003cstrong data-start=\"2097\" data-end=\"2114\"\u003eControl Type:\u003c\/strong\u003e Toggle\u003c\/li\u003e\n\u003cli data-section-id=\"1m5b7hs\" data-start=\"2124\" data-end=\"2157\"\u003e\n\u003cstrong data-start=\"2126\" data-end=\"2153\"\u003eBreaking Capacity Code:\u003c\/strong\u003e D\u003c\/li\u003e\n\u003cli data-section-id=\"1s1hptv\" data-start=\"2158\" data-end=\"2195\"\u003e\n\u003cstrong data-start=\"2160\" data-end=\"2181\"\u003ePhase Connection:\u003c\/strong\u003e B \u0026amp; C Phase\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1g5d8j4\" data-start=\"2202\" data-end=\"2228\"\u003eElectrical Performance\u003c\/h3\u003e\n\u003cul data-start=\"2230\" data-end=\"2615\"\u003e\n\u003cli data-section-id=\"81ig2i\" data-start=\"2230\" data-end=\"2256\"\u003e\n\u003cstrong data-start=\"2232\" data-end=\"2250\"\u003eRated Current:\u003c\/strong\u003e 60A\u003c\/li\u003e\n\u003cli data-section-id=\"1v8p00q\" data-start=\"2257\" data-end=\"2289\"\u003e\n\u003cstrong data-start=\"2259\" data-end=\"2279\"\u003eMaximum Voltage:\u003c\/strong\u003e 600V AC\u003c\/li\u003e\n\u003cli data-section-id=\"1rzypbe\" data-start=\"2290\" data-end=\"2335\"\u003e\n\u003cstrong data-start=\"2292\" data-end=\"2318\"\u003eInterrupting Capacity:\u003c\/strong\u003e 18kA @ 480V AC\u003c\/li\u003e\n\u003cli data-section-id=\"1oi0xwc\" data-start=\"2336\" data-end=\"2374\"\u003e\n\u003cstrong data-start=\"2338\" data-end=\"2368\"\u003eContinuous Current Rating:\u003c\/strong\u003e 80%\u003c\/li\u003e\n\u003cli data-section-id=\"n73pgz\" data-start=\"2375\" data-end=\"2410\"\u003e\n\u003cstrong data-start=\"2377\" data-end=\"2403\"\u003eMagnetic Hold Current:\u003c\/strong\u003e 800A\u003c\/li\u003e\n\u003cli data-section-id=\"do9l41\" data-start=\"2411\" data-end=\"2449\"\u003e\n\u003cstrong data-start=\"2413\" data-end=\"2427\"\u003eTrip Unit:\u003c\/strong\u003e Non-Interchangeable\u003c\/li\u003e\n\u003cli data-section-id=\"1h1tonz\" data-start=\"2450\" data-end=\"2501\"\u003e\n\u003cstrong data-start=\"2452\" data-end=\"2476\"\u003eOverload Protection:\u003c\/strong\u003e Long-Time Thermal Trip\u003c\/li\u003e\n\u003cli data-section-id=\"xtoiys\" data-start=\"2502\" data-end=\"2563\"\u003e\n\u003cstrong data-start=\"2504\" data-end=\"2533\"\u003eShort-Circuit Protection:\u003c\/strong\u003e Instantaneous Magnetic Trip\u003c\/li\u003e\n\u003cli data-section-id=\"9md7jw\" data-start=\"2564\" data-end=\"2615\"\u003e\n\u003cstrong data-start=\"2566\" data-end=\"2609\"\u003eSuitable for Reverse Feed Applications:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1qpthm9\" data-start=\"2622\" data-end=\"2660\"\u003eMechanical \u0026amp; Construction Features\u003c\/h3\u003e\n\u003cul data-start=\"2662\" data-end=\"3015\"\u003e\n\u003cli data-section-id=\"u0gwk2\" data-start=\"2662\" data-end=\"2698\"\u003eH-Frame molded case construction\u003c\/li\u003e\n\u003cli data-section-id=\"1hpcbsy\" data-start=\"2699\" data-end=\"2734\"\u003eCompact industrial-grade design\u003c\/li\u003e\n\u003cli data-section-id=\"1alw3pq\" data-start=\"2735\" data-end=\"2769\"\u003eI-Line plug-in mounting system\u003c\/li\u003e\n\u003cli data-section-id=\"1nus1yd\" data-start=\"2770\" data-end=\"2797\"\u003eToggle handle operation\u003c\/li\u003e\n\u003cli data-section-id=\"1tf21cz\" data-start=\"2798\" data-end=\"2848\"\u003eNon-interchangeable thermal-magnetic trip unit\u003c\/li\u003e\n\u003cli data-section-id=\"1b86qw8\" data-start=\"2849\" data-end=\"2888\"\u003eDurable molded insulating enclosure\u003c\/li\u003e\n\u003cli data-section-id=\"1bvdk4j\" data-start=\"2889\" data-end=\"2958\"\u003eDesigned for commercial and industrial power distribution systems\u003c\/li\u003e\n\u003cli data-section-id=\"1627u2o\" data-start=\"2959\" data-end=\"3015\"\u003eLong service life and reliable switching performance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"cn8pd9\" data-start=\"3022\" data-end=\"3048\"\u003eElectrical Connections\u003c\/h3\u003e\n\u003cul data-start=\"3050\" data-end=\"3223\"\u003e\n\u003cli data-section-id=\"1ndgc1w\" data-start=\"3050\" data-end=\"3089\"\u003e\n\u003cstrong data-start=\"3052\" data-end=\"3072\"\u003eLine Connection:\u003c\/strong\u003e I-Line Plug-In\u003c\/li\u003e\n\u003cli data-section-id=\"1w10knf\" data-start=\"3090\" data-end=\"3128\"\u003e\n\u003cstrong data-start=\"3092\" data-end=\"3112\"\u003eLoad Connection:\u003c\/strong\u003e Lug Terminals\u003c\/li\u003e\n\u003cli data-section-id=\"1kdq9vt\" data-start=\"3129\" data-end=\"3180\"\u003e\n\u003cstrong data-start=\"3131\" data-end=\"3159\"\u003eConductor Compatibility:\u003c\/strong\u003e Copper or Aluminum\u003c\/li\u003e\n\u003cli data-section-id=\"1gm3hyr\" data-start=\"3181\" data-end=\"3223\"\u003e\n\u003cstrong data-start=\"3183\" data-end=\"3203\"\u003eWire Size Range:\u003c\/strong\u003e AWG 14 to AWG 3\/0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"tsjdab\" data-start=\"3230\" data-end=\"3253\"\u003eDimensions \u0026amp; Weight\u003c\/h3\u003e\n\u003cul data-start=\"3255\" data-end=\"3333\"\u003e\n\u003cli data-section-id=\"1wbclh5\" data-start=\"3255\" data-end=\"3308\"\u003e\n\u003cstrong data-start=\"3257\" data-end=\"3284\"\u003eDimensions (H × W × D):\u003c\/strong\u003e 9.73\" × 2.94\" × 4.80\"\u003c\/li\u003e\n\u003cli data-section-id=\"uwebh1\" data-start=\"3309\" data-end=\"3333\"\u003e\n\u003cstrong data-start=\"3311\" data-end=\"3322\"\u003eWeight:\u003c\/strong\u003e 1.36 lbs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"wggvqn\" data-start=\"3340\" data-end=\"3356\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"3358\" data-end=\"3687\"\u003e\n\u003cli data-section-id=\"1b02wdy\" data-start=\"3358\" data-end=\"3404\"\u003eCommercial electrical distribution systems\u003c\/li\u003e\n\u003cli data-section-id=\"1kbdpgg\" data-start=\"3405\" data-end=\"3448\"\u003eIndustrial power distribution equipment\u003c\/li\u003e\n\u003cli data-section-id=\"1w0n024\" data-start=\"3449\" data-end=\"3478\"\u003eBranch circuit protection\u003c\/li\u003e\n\u003cli data-section-id=\"ur0r8t\" data-start=\"3479\" data-end=\"3508\"\u003eFeeder circuit protection\u003c\/li\u003e\n\u003cli data-section-id=\"c1588\" data-start=\"3509\" data-end=\"3540\"\u003eSquare D I-Line panelboards\u003c\/li\u003e\n\u003cli data-section-id=\"932g64\" data-start=\"3541\" data-end=\"3573\"\u003eSquare D I-Line switchboards\u003c\/li\u003e\n\u003cli data-section-id=\"ht42qz\" data-start=\"3574\" data-end=\"3602\"\u003eManufacturing facilities\u003c\/li\u003e\n\u003cli data-section-id=\"i5f45o\" data-start=\"3603\" data-end=\"3639\"\u003eOEM control panels and equipment\u003c\/li\u003e\n\u003cli data-section-id=\"1cf4heu\" data-start=\"3640\" data-end=\"3687\"\u003eElectrical system upgrades and replacements\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Square D","offers":[{"title":"NEW","offer_id":48533283864825,"sku":"HDA260604","price":727.65,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/HDA260252-new-1_0a55fbf3-0d58-4234-9df4-d44e0b574676.jpg?v=1781596879","url":"https:\/\/mycircuitbreakers.com\/products\/square-d-hda260604-powerpact-circuit-breaker-2-pole-60a-600v-thermal-magnetic-i-line-plug-in-18ka-480v","provider":"My Circuit Breakers","version":"1.0","type":"link"}